摘要
Wear debris, of deferent sizes, shapes and quantities, generated in artificial hip and knees is largely confined to the bone and joint interface. This debris interacts with periprosthetic tissue and may cause aseptic loosening. The purpose of this review is to summarize and collate findings of the recent demonstrations on debris characterization and their biological response that influences the occurrence in implant migration. A systematic review of peer-reviewed literature is performed, based on inclusion and exclusion criteria addressing mainly debris isolation, characterization, and biologic responses. Results show that debris characterization largely depends on their appropriate and accurate isolation protocol. The particles are found to be non-uniform in size and non-homogeneously distributed into the periprosthetic tissues. In addition, the sizes, shapes, and volumes of the particles are influenced by the types of joints, bearing geometry, material combination, and lubricant. Phagocytosis of wear debris is size dependent; high doses of submicron-sized particles induce significant level of secretion of bone resorbing factors. However, articles on wear debris from engineered surfaces (patterned and coated) are lacking. The findings suggest considering debris morphology as an important parameter to evaluate joint simulator and newly developed implant materials.
引用
收藏
页码:980 / 1016
页数:37
相关论文
共 170 条
[1]   Aseptic loosening of total joint replacements: mechanisms underlying osteolysis and potential therapies [J].
Abu-Amer, Yousef ;
Darwech, Isra ;
Clohisy, John C. .
ARTHRITIS RESEARCH & THERAPY, 2007, 9 (Suppl 1)
[2]  
American Academy of Orthopaedic Surgeons, 1995, ORTH RES SOC ANN M O
[3]  
American Society for Testing and Materials, 2000, F187798 ASTM SUBC
[4]  
[Anonymous], 1993, FRACTURE BRITTLE SOL, DOI DOI 10.1017/CBO9780511623127
[5]  
Bader R, 2008, ORTHOPADE, V37, P136, DOI 10.1007/s00132-007-1189-x
[6]   Tantalum-based multilayer coating on cobalt alloys in total hip and knee replacement [J].
Balagna, C. ;
Faga, M. G. ;
Spriano, S. .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2012, 32 (04) :887-895
[7]   Concerns about ceramics in THA [J].
Barrack, RL ;
Barak, C ;
Skinner, HB .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (429) :73-79
[8]   Comparison of Periprosthetic Tissue Digestion Methods for Ultra-High Molecular Weight Polyethylene Wear Debris Extraction [J].
Baxter, Ryan M. ;
Steinbeck, Maria J. ;
Tipper, Joanne L. ;
Parvizi, Javad ;
Marcolongo, Michele ;
Kurtz, Steve M. .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2009, 91B (01) :409-418
[9]   Transmission electron microscopy of intracellular particles of polyethylene from joint replacement prostheses: size distribution and cellular response [J].
Benz, EB ;
Federman, M ;
Godleski, JJ ;
Bierbaum, BE ;
Thornhill, TS ;
Spector, M .
BIOMATERIALS, 2001, 22 (21) :2835-2842
[10]  
Billi Fabrizio, 2009, SAS J, V3, P133, DOI 10.1016/j.esas.2009.11.006