The Biomechanical Significance of Washer Use With Screw Fixation

被引:32
作者
Bishop, Julius A. [1 ]
Behn, Anthony W. [1 ]
Castillo, Tiffany N. [1 ]
机构
[1] Stanford Univ, Med Ctr, Dept Orthopaed Surg, Palo Alto, CA 94304 USA
关键词
FRACTURES; INSERTION; TORQUE; MODEL;
D O I
10.1097/BOT.0b013e31829f9805
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives: Washers can be used with lag screws during fracture fixation to optimize compression and minimize the risk of unintentional intrusion of the screw head through cortical bone during screw insertion. The concept of using washers to optimize screw fixation is particularly applicable to iliosacral screw fixation and screw fixation of the femoral neck, distal femur, as well as the proximal and distal tibia. However, there is a paucity of literature on this topic. The purpose of this study was to detail the biomechanical consequences of washer use and screw intrusion. Methods: Partially threaded 7.0-mm cannulated screws with and without washers were placed through synthetic bone blocks fabricated to simulate cortical and cancellous bone. A load cell was used to measure the compressive force before and after screw intrusion. Screws were tested with a washer (n = 8), without a washer (n = 8), and with a washer after initially being intruded (n = 8). Results: Screws inserted with washers generated significantly more compressive force than screws inserted without washers before screw intrusion. After intrusion, compressive force decreased significantly under all conditions, but screws inserted with washers maintained greater compressive force than screws inserted without washers. Screws with washers reinserted after intrusion without a washer, produced almost as much compressive force as screws inserted with washers primarily. Conclusions: Screw intrusion during fracture fixation results in a loss of compressive force that may compromise fixation quality. Washers are advantageous in that they allow for more compression to be generated before intrusion occurs and can be used to salvage compressive force of intruded screws. © 2013 by Lippincott Williams and Wilkins.
引用
收藏
页码:114 / 117
页数:4
相关论文
共 12 条
[1]   Compression forces generated by Mini bone screws - a comparative study done on bone model [J].
Adla, DN ;
Kitsis, C ;
Miles, AW .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2005, 36 (01) :65-70
[2]   Osseous fixation pathways in pelvic and acetabular fracture surgery: Osteology, radiology, and clinical applications [J].
Bishop, Julius A. ;
Routt, Milton Lee , Jr. .
JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2012, 72 (06) :1502-1509
[3]   Transiliac-Transsacral Screws for Posterior Pelvic Stabilization [J].
Gardner, Michael J. ;
Routt, M. L. Chip, Jr. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2011, 25 (06) :378-384
[4]   Locked Transsacral Screw Fixation of Bilateral Injuries of the Posterior Pelvic Ring: Initial Clinical Series [J].
Moed, Berton R. ;
Whiting, Daniel R. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2010, 24 (10) :616-621
[5]   Biomechanical measurements of cortical screw stripping torque in human versus artificial femurs [J].
Nicayenzi, Bruce ;
Crookshank, Meghan ;
Olsen, Michael ;
Schemitsch, Emil H. ;
Bougherara, Habiba ;
Zdero, Rad .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2012, 226 (H8) :645-651
[6]   Percutaneous iliosacral screw fixation in S1 and S2 for posterior pelvic ring injuries: technique and perioperative complications [J].
Osterhoff, Georg ;
Ossendorf, Christian ;
Wanner, Guido A. ;
Simmen, Hans-Peter ;
Werner, Clement M. L. .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2011, 131 (06) :809-813
[7]   Predicting cancellous bone failure during screw insertion [J].
Reynolds, Karen J. ;
Cleek, Tammy M. ;
Mohtar, Aaron A. ;
Hearn, Trevor C. .
JOURNAL OF BIOMECHANICS, 2013, 46 (06) :1207-1210
[8]   A Comparison of Screw Insertion Torque and Pullout Strength [J].
Ricci, William M. ;
Tornetta, Paul, III ;
Petteys, Timothy ;
Gerlach, Darin ;
Cartner, Jacob ;
Walker, Zakiyyah ;
Russell, Thomas A. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2010, 24 (06) :374-378
[9]  
Shepard MF, 2002, CLIN ORTHOP RELAT R, P249
[10]   A biomechanical study on variation of compressive force along the Acutrak 2 screw [J].
Sugathan, Hari Kovilazhikathu ;
Kilpatrick, Max ;
Joyce, Tom J. ;
Harrison, John W. K. .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2012, 43 (02) :205-208