A low-count reconstruction algorithm for Compton-based prompt gamma imaging

被引:3
作者
Huang, Hsuan-Ming [1 ]
Liu, Chih-Chieh [2 ]
Jan, Meei-Ling [3 ,4 ,5 ]
Lee, Ming-Wei [3 ,4 ,5 ]
机构
[1] Natl Taiwan Univ, Coll Med, Inst Med Device & Imaging, 1,Sec 1,Jen Ai Rd, Taipei 100, Taiwan
[2] Univ Calif Davis, Dept Biomed Engn, Davis, CA 95616 USA
[3] Chang Gung Univ, Inst Radiol Res, Med Phys Res Ctr, 259 Wen Hwa 1st Rd, Kwei Shan 33302, Taoyuan County, Taiwan
[4] Chang Gung Mem Hosp, 259 Wen Hwa 1st Rd, Kwei Shan 33302, Taoyuan County, Taiwan
[5] Chang Gung Mem Hosp, Dept Radiat Oncol, 5 Fu Shin St, Kwei Shan 33302, Taoyuan County, Taiwan
关键词
proton therapy; Compton camera; prompt gamma ray; low count; RANGE VERIFICATION; PROTON THERAPY; EM ALGORITHM; RAY EMISSION; CAMERA; PET; SPACE;
D O I
10.1088/1361-6560/aab737
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The Compton camera is an imaging device which has been proposed to detect prompt gammas (PGs) produced by proton-nuclear interactions within tissue during proton beam irradiation. Compton-based PG imaging has been developed to verify proton ranges because PG rays, particularly characteristic ones, have strong correlations with the distribution of the proton dose. However, accurate image reconstruction from characteristic PGs is challenging because the detector efficiency and resolution are generally low. Our previous study showed that point spread functions can be incorporated into the reconstruction process to improve image resolution. In this study, we proposed a low-count reconstruction algorithm to improve the image quality of a characteristic PG emission by pooling information from other characteristic PG emissions. PGs were simulated from a proton beam irradiated on a water phantom, and a two-stage Compton camera was used for PG detection. The results show that the image quality of the reconstructed characteristic PG emission is improved with our proposed method in contrast to the standard reconstruction method using events from only one characteristic PG emission. For the 4.44 MeV PG rays, both methods can be used to predict the positions of the peak and the distal falloff with a mean accuracy of 2 mm. Moreover, only the proposed method can improve the estimated positions of the peak and the distal falloff of 5.25 MeV PG rays, and a mean accuracy of 2 mm can be reached.
引用
收藏
页数:9
相关论文
共 30 条
[1]  
[Anonymous], 2015, 2015 INT JOINT C NEU
[2]   Feasibility Studies of a New Event Selection Method to Improve Spatial Resolution of Compton Imaging for Medical Applications [J].
Draeger E. ;
Peterson S. ;
Mackin D. ;
Chen H. ;
Beddar S. ;
Polf J.C. .
IEEE Transactions on Radiation and Plasma Medical Sciences, 2017, 1 (04) :358-367
[3]  
Han GP, 1999, IEEE NUCL SCI CONF R, P1515, DOI 10.1109/NSSMIC.1999.842846
[4]   Proton therapy monitoring by Compton imaging: influence of the large energy spectrum of the prompt-γ radiation [J].
Hilaire, Estelle ;
Sarrut, David ;
Peyrin, Francoise ;
Maxim, Voichita .
PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (08) :3127-3147
[5]   Complementary frame reconstruction: a low-biased dynamic PET technique for low count density data in projection space [J].
Hong, Inki ;
Cho, Sanghee ;
Michel, Christian J. ;
Casey, Michael E. ;
Schaefferkoetter, Joshua D. .
PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (18) :5441-5455
[6]   Compton Camera and Prompt Gamma Ray Timing: Two Methods for In Vivo Range Assessment in Proton Therapy [J].
Hueso-Gonzalez, Fernando ;
Fiedler, Fine ;
Golnik, Christian ;
Kormoll, Thomas ;
Pausch, Guntram ;
Petzoldt, Johannes ;
Roemer, Katja E. ;
Enghardt, Wolfgang .
FRONTIERS IN ONCOLOGY, 2016, 6
[7]   PSF reconstruction for Compton-based prompt gamma imaging [J].
Jan, Meei-Ling ;
Lee, Ming-Wei ;
Huang, Hsuan-Ming .
PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (03)
[8]   Use of a LYSO-based Compton camera for prompt gamma range verification in proton therapy [J].
Jan, Meei-Ling ;
Hsiao, Ing-Tsung ;
Huang, Hsuan-Ming .
MEDICAL PHYSICS, 2017, 44 (12) :6261-6269
[9]   Fully three-dimensional OSEM-based image reconstruction for Compton imaging using optimized ordering schemes [J].
Kim, Soo Mee ;
Lee, Jae Sung ;
Lee, Chun Sik ;
Kim, Chan Hyeong ;
Lee, Myung Chul ;
Lee, Dong Soo ;
Lee, Soo-Jin .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (17) :5007-5027
[10]   In vivo proton range verification: a review [J].
Knopf, Antje-Christin ;
Lomax, Antony .
PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (15) :131-160