Validation of the BOD POD with hydrostatic weighing: Influence of body clothing

被引:101
作者
Fields, DA
Hunter, GR
Goran, MI
机构
[1] Univ Alabama, Dept Nutr Sci & Human Studies, Div Physiol & Metab, Birmingham, AL 35294 USA
[2] Univ So Calif, Inst Prevent Res, Dept Prevent Med, Los Angeles, CA USA
关键词
BOD POD; plethysmography; air-displacement; body composition;
D O I
10.1038/sj.ijo.0801113
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE: Whole body air-displacement plethysmography (BOD POD), a new body composition technique, was validated against hydrodensitometry (UWW) in 67 women wearing a one-piece swimsuit (OP) who represent a wide range of body fatness and age. Additionally, the effect of trapped isothermic air in clothing while in the BOD POD was examined by comparing different clothing schemes (a one-piece swimsuit (OP), two-piece swimsuit (TP), a hospital gown (HG), and a hospital gown previously included in a volume calibration (GC)) in a subset of 25 women. DESIGN: Cross-sectional data analysis. SUBJECTS: 67 healthy Caucasian females. MEASUREMENTS: Body density g/cm(3) (Db) by BOD POD and UWW. RESULTS: In 67 females UWW Db (1.030 +/- 0.020 g/cm(3)) was higher (P < 0.01) than BOD POD Db (1.028 +/- 0.020 g/cm(3)). This is a difference of 1.0% fat. The R-2 was 0.94, SEE was 0.005 g/cm(3) and the regression between Db by UW-Wand BOD POB did not significantly deviate from the line of identity. In the subset group of 25 subjects, OP Db (1.040 +/- 0.014 g/cm(3)) and TP Db (1.040 +/- 0.014 g/cm(3)) were significantly lower (Pt0.01) than UW-W Db (1.044 +/- 0.014 g/cm(3)) or a difference of 1.9% fat. The R-2 was 0.86 and the SEE was 0.005 g/cm(3) and the regression between Db by UWW and both OP and TP did not significantly deviate from the line of identity. HG Db (1.056 +/- 0.016 g/cm(3)) and GC Db (1.037 +/- 0.016 g/cm(3)) were significantly different (P < 0.01) from UWW Db (1.044 +/- 0.014 g/cm(3)). This difference in density translates to a difference of 5.5% and 3.2% fat respectively. The regression between Db by UWW and both HG and GC significantly deviated from the line of identity. CONCLUSION: This study supports the use of the BOD POD as a substitute for UWW. However, caution should be made in using the BOD POD if subjects are clothed in anything other than a tight fitting swimsuit.
引用
收藏
页码:200 / 205
页数:6
相关论文
共 10 条
[1]  
Biaggi RR, 1999, AM J CLIN NUTR, V69, P898
[2]  
DEMPSTER P, 1995, MED SCI SPORT EXER, V27, P1692
[3]   RAPID PLETHYSMOGRAPHIC METHOD FOR MEASURING THORACIC GAS VOLUME - COMPARISON WITH A NITROGEN WASHOUT METHOD FOR MEASURING FUNCTIONAL RESIDUAL CAPACITY IN NORMAL SUBJECTS [J].
DUBOIS, AB ;
BOTELHO, SY ;
BEDELL, GN ;
MARSHALL, R ;
COMROE, JH .
JOURNAL OF CLINICAL INVESTIGATION, 1956, 35 (03) :322-326
[4]  
LOHMAN TG, 1986, EXERCISE SPORT SCI R, V14, P325
[5]  
MCCRORY MA, 1995, MED SCI SPORT EXER, V27, P1686
[6]   Body composition in children and adults by air displacement plethysmography [J].
Nuñez, C ;
Kovera, AJ ;
Pietrobelli, A ;
Heshka, S ;
Horlick, M ;
Kehayias, JJ ;
Wang, Z ;
Heymsfield, SB .
EUROPEAN JOURNAL OF CLINICAL NUTRITION, 1999, 53 (05) :382-387
[7]   EFFECT OF THE THERMODYNAMICS OF AN INFANT PLETHYSMOGRAPH ON THE MEASUREMENT OF THORACIC GAS VOLUME [J].
SLY, PD ;
LANTERI, C ;
BATES, JHT .
PEDIATRIC PULMONOLOGY, 1990, 8 (03) :203-208
[8]   DEVELOPMENT OF AN AIR DISPLACEMENT METHOD FOR WHOLE-BODY VOLUME MEASUREMENT OF INFANTS [J].
TAYLOR, A ;
AKSOY, Y ;
SCOPES, JW ;
DUMONT, G ;
TAYLOR, BA .
JOURNAL OF BIOMEDICAL ENGINEERING, 1985, 7 (01) :9-17
[9]   A SIMPLIFIED METHOD FOR DETERMINATION OF RESIDUAL LUNG VOLUMES [J].
WILMORE, JH .
JOURNAL OF APPLIED PHYSIOLOGY, 1969, 27 (01) :96-&
[10]  
ZUMDAHL SS, 1989, CHEMISTRY, P178