Optimal High b-Value for Diffusion Weighted MRI in Diagnosing High Risk Prostate Cancers in the Peripheral Zone

被引:42
作者
Agarwal, Harsh K. [1 ,2 ]
Mertan, Francesca V. [1 ]
Sankineni, Sandeep [1 ]
Bernardo, Marcelino [1 ,3 ]
Senegas, Julien [4 ]
Keupp, Jochen [4 ]
Daar, Dagane [1 ,3 ]
Merino, Maria [5 ]
Wood, Bradford J. [6 ,7 ]
Pinto, Peter A. [8 ]
Choyke, Peter L. [1 ]
Turkbey, Baris [1 ]
机构
[1] NCI, Mol Imaging Program, NIH, Bethesda, MD 20892 USA
[2] Philips Res North Amer, Cambridge, MA USA
[3] Frederick Natl Lab Canc Res, Leidos Biomed Res Inc, Frederick, MD USA
[4] Philips Res Labs, Hamburg, Germany
[5] NCI, Pathol Lab, NIH, Bldg 10, Bethesda, MD 20892 USA
[6] NCI, Ctr Intervent Oncol, Bethesda, MD 20892 USA
[7] NIH, Radiol & Imaging Sci, Ctr Clin, Bldg 10, Bethesda, MD 20892 USA
[8] NCI, Urol Oncol Branch, NIH, Bethesda, MD 20892 USA
关键词
RADICAL PROSTATECTOMY; CLINICAL UTILITY; TUMOR-DETECTION; 3; T; LOCALIZATION; FUSION; AGGRESSIVENESS; RECURRENCE; CONTRAST; CURVES;
D O I
10.1002/jmri.25353
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To retrospectively determine the optimal b-value(s) of diffusion-weighted imaging (DWI) associated with intermediate-high risk cancer in the peripheral zone (PZ) of the prostate. Materials and Methods: Forty-two consecutive patients underwent multi b-value (16 evenly spaced b-values between 0 and 2000 s/mm(2)) DWI along with multi-parametric MRI (MP-MRI) of the prostate at 3 Tesla followed by trans-rectal ultrasound/MRI fusion guided targeted biopsy of suspicious lesions detected at MP-MRI. Computed DWI images up to a simulated b-value of 4000 s/mm(2) were also obtained using a pair of b-values (b = 133 and 400 or 667 or 933 s/mm(2)) from the multi b-value DWI. The contrast ratio of average intensity of the targeted lesions and the background PZ was determined. Receiver operator characteristic curves and the area under the curve (AUCs) were obtained for separating patients eligible for active surveillance with low risk prostate cancers from intermediate-high risk prostate cancers as per the cancer of the prostate risk assessment (CAPRA) scoring system. Results: The AUC first increased then decreased with the increase in b-values reaching maximum at b = 1600 s/mm(2) (0.74) with no statistically significant different AUC of DWI with b-values 1067-2000 s/mm(2). The AUC of computed DWI increased then decreased with the increase in b-values reaching a maximum of 0.75 around b = 2000 s/mm(2). There was no statistically significant difference between the AUC of optimal acquired DWI and either of optimal computed DWI. Conclusion: The optimal b-value for acquired DWI in differentiating intermediate-high from low risk prostate cancers in the PZ is b = 1600 s/mm(2). The computed DWI has similar performance as that of acquired DWI with the optimal performance around b = 2000 s/mm(2).
引用
收藏
页码:125 / 131
页数:7
相关论文
共 35 条
[1]   ESUR prostate MR guidelines 2012 [J].
Barentsz, Jelle O. ;
Richenberg, Jonathan ;
Clements, Richard ;
Choyke, Peter ;
Verma, Sadhna ;
Villeirs, Geert ;
Rouviere, Olivier ;
Logager, Vibeke ;
Futterer, Jurgen J. .
EUROPEAN RADIOLOGY, 2012, 22 (04) :746-757
[2]   Multiinstitutional validation of the UCSF cancer of the prostate risk assessment for prediction of recurrence after radical prostatectomy [J].
Cooperberg, Matthew R. ;
Freedland, Stephen J. ;
Pasta, David J. ;
Elkin, Eric P. ;
Presti, Joseph C., Jr. ;
Amling, Christopher L. ;
Terris, Martha K. ;
Aronson, William J. ;
Kane, Christopher J. ;
Carroll, Peter R. .
CANCER, 2006, 107 (10) :2384-2391
[3]   The University of California, San Francisco cancer of the prostate risk assessment score: A straightforward and reliable preoperative predictor of disease recurrence after radical prostatectomy [J].
Cooperberg, MR ;
Pasta, DJ ;
Elkin, EP ;
Litwin, MS ;
Latini, DM ;
DuChane, J ;
Carroll, PR .
JOURNAL OF UROLOGY, 2005, 173 (06) :1938-1942
[4]   Multiparametric magnetic resonance imaging for the detection and localization of prostate cancer: combination of T2-weighted, dynamic contrast-enhanced and diffusion-weighted imaging [J].
Delongchamps, Nicolas Barry ;
Rouanne, Mathieu ;
Flam, Thierry ;
Beuvon, Frederic ;
Liberatore, Mathieu ;
Zerbib, Marc ;
Cornud, Francois .
BJU INTERNATIONAL, 2011, 107 (09) :1411-1418
[5]   Computed high b-value diffusion-weighted imaging improves lesion contrast and conspicuity in prostate cancer [J].
Feuerlein, S. ;
Davenport, M. S. ;
Krishnaraj, A. ;
Merkle, E. M. ;
Gupta, R. T. .
PROSTATE CANCER AND PROSTATIC DISEASES, 2015, 18 (02) :155-160
[6]   Comparison of calculated and acquired high b value diffusion-weighted imaging in prostate cancer [J].
Grant, Kinzya B. ;
Agarwal, Harsh K. ;
Shih, Joanna H. ;
Bernardo, Marcelino ;
Pang, Yuxi ;
Daar, Dagane ;
Merino, Maria J. ;
Wood, Bradford J. ;
Pinto, Peter A. ;
Choyke, Peter L. ;
Turkbey, Baris .
ABDOMINAL IMAGING, 2015, 40 (03) :578-586
[7]   Relationship between Apparent Diffusion Coefficients at 3.0-T MR Imaging and Gleason Grade in Peripheral Zone Prostate Cancer [J].
Hambrock, Thomas ;
Somford, Diederik M. ;
Huisman, Henkjan J. ;
van Oort, Inge M. ;
Witjes, J. Alfred ;
Hulsbergen-van de Kaa, Christina A. ;
Scheenen, Thomas ;
Barentsz, Jelle O. .
RADIOLOGY, 2011, 259 (02) :453-461
[8]   A METHOD OF COMPARING THE AREAS UNDER RECEIVER OPERATING CHARACTERISTIC CURVES DERIVED FROM THE SAME CASES [J].
HANLEY, JA ;
MCNEIL, BJ .
RADIOLOGY, 1983, 148 (03) :839-843
[9]   THE MEANING AND USE OF THE AREA UNDER A RECEIVER OPERATING CHARACTERISTIC (ROC) CURVE [J].
HANLEY, JA ;
MCNEIL, BJ .
RADIOLOGY, 1982, 143 (01) :29-36
[10]   Prostate Cancer: Multiparametric MR Imaging for Detection, Localization, and Staging [J].
Hoeks, Caroline M. A. ;
Barentsz, Jelle O. ;
Hambrock, Thomas ;
Yakar, Derya ;
Somford, Diederik M. ;
Heijmink, Stijn W. T. P. J. ;
Scheenen, Tom W. J. ;
Vos, Pieter C. ;
Huisman, Henkjan ;
van Oort, Inge M. ;
Witjes, J. Alfred ;
Heerschap, Arend ;
Fuetterer, Jurgen J. .
RADIOLOGY, 2011, 261 (01) :46-66