Atrazine contamination at the watershed scale and environmental factors affecting sampling rates of the polar organic chemical integrative sampler (POCIS)

被引:64
作者
Dalton, Rebecca L. [1 ]
Pick, Frances R. [1 ]
Boutin, Celine [1 ,2 ]
Saleem, Ammar [1 ]
机构
[1] Univ Ottawa, Ottawa Carleton Inst Biol, Ottawa, ON K1N 6N5, Canada
[2] Carleton Univ, Environm Canada, Sci & Technol Branch, Ottawa, ON K1A 0H3, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Polar organic chemical integrative sampler (POCIS); Performance reference compound; Passive sampling rate; Herbicide; Atrazine; PERFORMANCE REFERENCE COMPOUNDS; SEMIPERMEABLE-MEMBRANE DEVICES; AQUATIC ENVIRONMENTS; SURFACE WATERS; SPRING RUNOFF; GROUND-WATER; IN-SITU; RIVER; CALIBRATION; HERBICIDES;
D O I
10.1016/j.envpol.2014.02.028
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Polar organic chemical integrative samplers (POCIS) were used to estimate atrazine contamination at 24 stream/river sites located across a watershed with land use ranging from 6.7 to 97.4% annual crops and surface water nitrate concentrations ranging from 3 to 5404 mu g/L. A gradient of atrazine contamination spanning two orders of magnitude was observed over two POCIS deployments of 28 d and was positively correlated with measures of agricultural intensity. The metabolite desisopropyl atrazine was used as a performance reference compound in field calibration studies. Sampling rates were similar between field sites but differed seasonally. Temperature had a significant effect on sampling rates while other environmental variables, including water velocity, appeared to have no effect on sampling rates. A performance reference compound approach showed potential in evaluating spatial and temporal differences in field sampling rates and as a tool for further understanding processes governing uptake of polar compounds by POCIS. (C) 2014 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:134 / 142
页数:9
相关论文
共 52 条
[1]  
Agriculture and Agri-Food Canada, 2008, LAND COV AGR REG CAN
[2]   Development of a passive, in situ, integrative sampler for hydrophilic organic contaminants in aquatic environments [J].
Alvarez, DA ;
Petty, JD ;
Huckins, JN ;
Jones-Lepp, TL ;
Getting, DT ;
Goddard, JP ;
Manahan, SE .
ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY, 2004, 23 (07) :1640-1648
[3]  
Alvarez DA, 2007, COMP ANAL C, V48, P171, DOI 10.1016/S0166-526X(06)48008-9
[4]  
[Anonymous], 2012, PEST TOP CHEM FACT S
[5]  
[Anonymous], 1999, CAN ENV QUAL GUID, P1
[6]  
[Anonymous], 2006, CENS AGR
[7]  
Asman W., 2003, PESTICIDE RES, V66, P1
[8]   Calibrating the uptake kinetics of semipermeable membrane devices using exposure standards [J].
Booij, K ;
Sleiderink, HM ;
Smedes, F .
ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY, 1998, 17 (07) :1236-1245
[9]   Spiking of performance reference compounds in low density polyethylene and silicone passive water samplers [J].
Booij, K ;
Smedes, F ;
van Weerlee, EM .
CHEMOSPHERE, 2002, 46 (08) :1157-1161