摘要
For accelerometers targeted in inertial navigation field, the DC bias error is the most destructive system error, affecting the final precision of long-term dead reckoning. This paper proposes a novel self-test and self-calibration technique for canceling out the DC bias error of the digital closed-loop accelerometers. The self-test of system DC bias is realized by injecting a 1-Bit sigma increment modulated digital excitation and measuring the second-order harmonic distortion. As illustrated, the second-order harmonic distortion is related to the servo position deviation of the MEMS sensing element, which is one of the main causes of system DC bias error. The automatic capacitance compensation is carried out based on the amplitude and phase information of the detected second-order harmonic distortion, which can dynamically calibrate out the DC bias error. Test results show that there exists a near-linearity relationship between the system DC bias error and the second-order harmonic distortion, which is consistent with the proposed theoretical deduction. Based on the proposed method, the system DC bias error is effectively reduced from 150 to 4 mg, and unaffected by external acceleration bias.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Research on closed-loop self-calibration of delta mechanism
    Zhu, Yanhe
    Zhao, Jie
    Cai, Hegao
    Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 2005, 39 (02): : 134 - 137
  • [2] Self-test and self-calibration of a MEMS convective accelerometer
    Rekik, A. A.
    Azais, F.
    Mailly, F.
    Nouet, P.
    Rekik, A. A.
    Masmoudi, M.
    2013 SYMPOSIUM ON DESIGN, TEST, INTEGRATION AND PACKAGING OF MEMS/MOEMS (DTIP), 2013,
  • [3] A ΣΔ Closed-Loop Interface for a MEMS Accelerometer with Digital Built-In Self-Test Function
    Chen, Dongliang
    Liu, Xiaowei
    Yin, Liang
    Wang, Yinhang
    Shi, Zhaohe
    Zhang, Guorui
    MICROMACHINES, 2018, 9 (09)
  • [4] Design of interface circuit of closed-loop accelerometer with self-test function
    Liu, Yun-Tao
    Yin, Liang
    Chen, Wei-Ping
    Wu, Qun
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2009, 17 (06): : 1379 - 1384
  • [5] Self-Test, Self-Calibration and Self-Repair Methodology of Thermopile Infrared Detector
    Zhou, Kaiyue
    Li, Jia
    Wang, Weibing
    Chen, Dapeng
    ELECTRONICS, 2021, 10 (10)
  • [6] Design of self-test and self-calibration systems for analog active RC filters
    Kladovscikov, Leonid
    Navickas, Romualdas
    2017 5TH IEEE WORKSHOP ON ADVANCES IN INFORMATION, ELECTRONIC AND ELECTRICAL ENGINEERING (AIEEE'2017), 2017,
  • [7] New self-test and self-calibration concept for micro-machined gyroscopes
    Link, T
    Simon, I
    Trächtler, M
    Gaisser, A
    Braxmaier, M
    Manoli, Y
    Sandmaier, H
    TRANSDUCERS '05, DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, 2005, : 401 - 404
  • [8] Built-in self-test and self-calibration for analog and mixed signal circuits
    Chen, Tao
    Chen, Degang
    2019 IEEE INTERNATIONAL TEST CONFERENCE (ITC), 2019,
  • [9] Closed-loop control for self-calibration of accelerometer achieved through integrated sensor and actuator system
    Li, Xiaoshi
    Wang, Yicheng
    Yang, Tianyu
    Du, Yijia
    Chen, Yu
    Gong, Dongdong
    Zhou, Quanfeng
    Sun, Xiangyu
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2021, 27 (08): : 3025 - 3035
  • [10] A closed-loop kinematic approach to Self-Calibration of joint offset for multi-branched robots
    Zhao, Chuanlin
    Qian, Letian
    Wang, Shuhan
    Jia, Yuyi
    Luo, Xin
    MEASUREMENT, 2024, 238