Comparison of dual energy detector system performance

被引:97
作者
Alvarez, RE [1 ]
Seibert, JA
Thompson, SK
机构
[1] Aprend Technol, Mountain View, CA 94043 USA
[2] Univ Calif Davis, Dept Radiol, Sacramento, CA 95817 USA
[3] Univ Texas, MD Anderson Canc Ctr, Houston, TX 77030 USA
关键词
dual energy; x-ray; spectrum; noise; motion-artifact;
D O I
10.1118/1.1645679
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Dual energy detector systems Are combinations of x-ray detectors, x-ray source spectrum switching, and x-ray filter attenuation that provide two measurements of transmitted flux through the object with different effective spectra. We describe technology independent methods to measure and compare the quantum noise and sensitivity to motion artifacts of these systems. The experimental methods use relatively simple phantoms to measure the parameters in the general mathematical expressions for the noise in the subtracted image. The parameters are used to compute an x-ray energy spectrum quality factor and a subtracted image noise per unit patient dose quality factor. Patient motion causes artifacts in switched spectrum systems, particularly with the heart in chest radiography. We describe a method to measure effective interexposure time using subtracted image data of a uniformly moving object. This parameter measures the sensitivity to patient motion artifacts. We use these methods to compare three examples of systems with different dual energy detector technologies: a passive, "sandwich" detector with two computed radiography plates separated by a copper filter, an "active" detector that uses voltage switching with an electro-optical system and computed radiography plates, and a fiat-panel, solid state detector with voltage switching. (C) 2004 American Association of Physicists in Medicine.
引用
收藏
页码:556 / 565
页数:10
相关论文
共 21 条
[1]  
Alvarez R E, 1977, U.S. Patent, Patent No. [4 029 963 1977 (USA), 4029963]
[2]   Active energy selective image detector for dual-energy computed radiography [J].
Alvarez, RE .
MEDICAL PHYSICS, 1996, 23 (10) :1739-1748
[3]   ENERGY-SELECTIVE RECONSTRUCTIONS IN X-RAY COMPUTERIZED TOMOGRAPHY [J].
ALVAREZ, RE ;
MACOVSKI, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (05) :733-744
[4]  
[Anonymous], TABLES XRAY MASS ATT, DOI DOI 10.18434/T4D01F
[5]   A COMPARISON OF DUAL-ENERGY DIGITAL RADIOGRAPHY AND SCREEN-FILM IMAGING IN THE DETECTION OF SUBTLE INTERSTITIAL PULMONARY-DISEASE [J].
BARNES, GT ;
SABBAGH, EA ;
CHAKRABORTY, DP ;
NATH, PH ;
LUNA, RF ;
SANDERS, C ;
FRASER, RG .
INVESTIGATIVE RADIOLOGY, 1989, 24 (08) :585-591
[6]   The design of a system for coloured digital radiology with VLSI circuits and GaAs pixel detectors [J].
Cadeddu, S ;
Caligiore, C ;
Caria, M ;
Lai, A ;
LoPresti, D ;
Panebianco, S ;
Petta, C ;
Porcu, P ;
Randazzo, N ;
Randaccio, P ;
Reito, S ;
Russo, GV .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 419 (2-3) :270-275
[7]   USE OF DIFFERENTIAL TOMOGRAPHY IN THE STUDY OF NATURAL PROCESSES [J].
CESAREO, R ;
MAHTABOALLY, SQG .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1989, 8 (02) :163-167
[8]   AN ENERGY SENSITIVE CASSETTE FOR DUAL-ENERGY MAMMOGRAPHY [J].
CHAKRABORTY, DP ;
BARNES, GT .
MEDICAL PHYSICS, 1989, 16 (01) :7-13
[9]   Signal-to-noise optimization of medical imaging systems [J].
Cunningham, IA ;
Shaw, R .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1999, 16 (03) :621-632
[10]   Experimental comparison of noise and resolution for 2k and 4k storage phosphor radiography systems [J].
Flynn, MJ ;
Samei, E .
MEDICAL PHYSICS, 1999, 26 (08) :1612-1623