An in vitro evaluation of a new cannula tip design compared with two clinically established cannula-tip designs regarding aortic arch vessel perfusion characteristics

被引:13
作者
Joubert-Huebner, E [1 ]
Gerdes, A [1 ]
Sievers, HH [1 ]
机构
[1] Univ Lubeck, Dept Cardiac Surg, D-23538 Lubeck, Germany
来源
PERFUSION-UK | 2000年 / 15卷 / 01期
关键词
D O I
10.1177/026765910001500110
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We investigated in vitro aortic arch vessel perfusion characteristics of single and multiple jet-stream cannulae and a new dispersion stream tip aortic cannula. Pressures and flows of all arch vessels were measured while directing cannulae jets at the different arch vessels using 6 l/min pump flow. The highest increase in pressure above the set systemic level of 80 mmHg and increase in flow above the set normal flow distribution in the arch vessels occurred in the jet-streamed arch Vessels with the single stream cannula. The values were as follows: 29 mmHg and 188 ml/min for the innominate artery, 28 mmHg and 42 ml/min for the left common carotid artery, and 25 mmHg and 54 ml/min for the left subclavian artery. The dispersion stream cannula showed increases in pressure and flow, followed by the multiple stream cannula. Aortic cannula tips and the orientation of jets are potential sources of imbalances of arch vessel perfusion with possible clinical implications regarding perfusion of arch vessels during extracorporeal circulation.
引用
收藏
页码:69 / 76
页数:8
相关论文
共 22 条
[1]   Cerebral monitoring during cardiopulmonary bypass [J].
Ali, M. I. ;
Smith, P. L. ;
Brannan, J. J. ;
Taylor, K. M. .
PERFUSION-UK, 1996, 11 (04) :299-312
[2]   SPONTANEOUS CEREBELLAR HEMORRHAGE AFTER CORONARY-ARTERY BYPASS-SURGERY [J].
ANDERSON, DE ;
BILLER, J ;
SCHREIBER, RR .
EUROPEAN NEUROLOGY, 1985, 24 (03) :145-148
[3]   A COMPARISON OF FLOW GRADIENTS ACROSS DISPOSABLE ARTERIAL PERFUSION CANNULAS [J].
BRODMAN, R ;
SIEGEL, H ;
LESSER, M ;
FRATER, R .
ANNALS OF THORACIC SURGERY, 1985, 39 (03) :225-233
[4]  
Groom Robert C., 1995, Perfusion, V10, P183, DOI 10.1177/026765919501000310
[5]   BRAIN-SWELLING IN 1ST HOUR AFTER CORONARY-ARTERY BYPASS-SURGERY [J].
HARRIS, DN ;
BAILEY, SM ;
SMITH, PLC ;
TAYLOR, KM ;
OATRIDGE, A ;
BYDDER, GM .
LANCET, 1993, 342 (8871) :586-587
[6]   Cerebral swelling after normothermic cardiopulmonary bypass [J].
Harris, DNF ;
Oatridge, A ;
Dob, D ;
Smith, PLC ;
Taylor, KM ;
Bydder, GM .
ANESTHESIOLOGY, 1998, 88 (02) :340-345
[7]  
HENRIKSEN L, 1983, J THORAC CARDIOV SUR, V86, P202
[8]   CEREBRAL-HEMORRHAGE FOLLOWING HEART-SURGERY [J].
HUMPHREYS, RP ;
HOFFMAN, HJ ;
MUSTARD, WT ;
TRUSLER, GA .
JOURNAL OF NEUROSURGERY, 1975, 43 (06) :671-675
[9]   SUBDURAL HEMATOMA FOLLOWING OPEN-HEART OPERATIONS [J].
KROUS, HF ;
TENCKHOFF, L ;
GOULD, NS ;
STAMM, SJ .
ANNALS OF THORACIC SURGERY, 1975, 19 (03) :269-276
[10]  
KROUS HF, 1973, J THORAC CARDIOV SUR, V66, P118