摘要
This paper addresses the effect of the electrostatic field due to extra high voltage (EHV) overhead transmission lines on pipelines in the vicinity of those power lines. Two measures for this effect are used: the maximum electric field on the pipe surface and the total electric charge on the pipeline per unit length. A mathematical model is presented for assessing these two measures. The results of applying the model to a situation involving a single-circuit, six-bundle, three-phase, 750-kV EHV line with flat conductor configuration are presented and discussed. The first set of results refers to a parallel pipeline of radius 0.5 m. The dependence of both the maximum electric field (at the top of the pipe) and the charge per meter on the distance between the pipeline and the tower center is similar to the distribution of the electric field beneath the tower at the ground surface. It shows maxima of both quantities if the pipe is exactly under one of the outer phases of the power line. At a distance of about 35 m from the tower center, both the electric field and the charge per unit length drop to 50% of their maximum values. The electric field is found to increase almost linearly with the clearance between the pipeline and the ground surface. The charge changes in a more complicated way with the clearance. It decreases if the pipe clearance increases from 0 to 0.2 m, then increases steadily beyond this value. For a given distance from the 750-kV line and for a fixed clearance from the ground, both the electric field and the electric charge per unit length on the pipeline will increase with the pipe radius. This paper will deal also with the impact of the pipeline on the nearby EHV power line and its associated network. The results will show that for a solidly earthed power network, the presence of the pipeline will be accompanied by a slight increase in the neutral current. On the other hand, for a power network with an inductively earthed neutral, there will be a tendency toward a parallel resonance that can occur for particular values of the neutral inductance and pipe radius. This resonance will result in an increase in the system's neutral potential, which will be primarily limited by the network losses.
引用
收藏
页码:1225 / 1231
页数:7
相关论文
共 50 条
  • [21] Analysis of mutual communication between qubits by capacitive coupling
    Murakami, T
    Iinuma, M
    Takahashi, T
    Kadoya, Y
    Yamanishi, M
    PHYSICAL REVIEW A, 2003, 67 (05):
  • [22] Analysis of mutual communication between qubits by capacitive coupling
    Murakami, Takahiro
    Iinuma, Masataka
    Takahashi, Tohru
    Kadoya, Yutaka
    Yamanishi, Masamichi
    Physical Review A - Atomic, Molecular, and Optical Physics, 2003, 67 (05): : 503011 - 503014
  • [23] Design economics of EHV power lines
    Kishore, T. S.
    Singal, S. K.
    2014 INTERNATIONAL CONFERENCE ON ADVANCES IN ELECTRICAL ENGINEERING (ICAEE), 2014,
  • [24] Calculation of inductive coupling from power lines to multiple pipelines and buried conductors
    Djogo, G
    Salama, MMA
    ELECTRIC POWER SYSTEMS RESEARCH, 1997, 41 (01) : 75 - 84
  • [25] EMPIRICAL RELATIONS FOR CAPACITIVE AND INDUCTIVE COUPLING-COEFFICIENTS OF COUPLED MICROSTRIP LINES
    KAL, S
    BHATTACHARYA, D
    CHAKRABORTI, NB
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1981, 29 (04) : 386 - 388
  • [26] Influence of Lossy Ground on High-Frequency Induced Voltages on Aboveground Pipelines by Nearby Overhead Transmission Lines
    Martins-Britto, Amauri G.
    Papadopoulos, Theofilos A.
    Datsios, Zacharias G.
    Chrysochos, Andreas, I
    Papagiannis, Grigoris K.
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2022, 64 (06) : 2273 - 2282
  • [27] Electromagnetic interference between electrical power lines and neighboring pipelines
    Hossam-Eldin, Ahmed A.
    Mokhtar, Wael
    ICSENG 2008: INTERNATIONAL CONFERENCE ON SYSTEMS ENGINEERING, 2008, : 97 - 102
  • [29] SHIFT-VOLTAGES OF MULTIPLE TRANSMISSION-LINES BY INDUCTIVE AND CAPACITIVE COUPLING
    HELLE, W
    ETZ ARCHIV, 1980, 2 (03): : 71 - 75
  • [30] Inductive interference on pipelines buried in multilayer soil due to magnetic fields from nearby faulted power lines
    Christoforidis, GC
    Labridis, DP
    Dokopoulos, PS
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2005, 47 (02) : 254 - 262