The capacitive coupling between EHV lines and nearby pipelines

被引:21
|
作者
Saied, MM [1 ]
机构
[1] Kuwait Univ, Dept Elect Engn, Safat 13060, Kuwait
关键词
capacitive coupling; electrostatic interference; extra high voltage (EHV) lines; pipelines;
D O I
10.1109/TPWRD.2003.823211
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper addresses the effect of the electrostatic field due to extra high voltage (EHV) overhead transmission lines on pipelines in the vicinity of those power lines. Two measures for this effect are used: the maximum electric field on the pipe surface and the total electric charge on the pipeline per unit length. A mathematical model is presented for assessing these two measures. The results of applying the model to a situation involving a single-circuit, six-bundle, three-phase, 750-kV EHV line with flat conductor configuration are presented and discussed. The first set of results refers to a parallel pipeline of radius 0.5 m. The dependence of both the maximum electric field (at the top of the pipe) and the charge per meter on the distance between the pipeline and the tower center is similar to the distribution of the electric field beneath the tower at the ground surface. It shows maxima of both quantities if the pipe is exactly under one of the outer phases of the power line. At a distance of about 35 m from the tower center, both the electric field and the charge per unit length drop to 50% of their maximum values. The electric field is found to increase almost linearly with the clearance between the pipeline and the ground surface. The charge changes in a more complicated way with the clearance. It decreases if the pipe clearance increases from 0 to 0.2 m, then increases steadily beyond this value. For a given distance from the 750-kV line and for a fixed clearance from the ground, both the electric field and the electric charge per unit length on the pipeline will increase with the pipe radius. This paper will deal also with the impact of the pipeline on the nearby EHV power line and its associated network. The results will show that for a solidly earthed power network, the presence of the pipeline will be accompanied by a slight increase in the neutral current. On the other hand, for a power network with an inductively earthed neutral, there will be a tendency toward a parallel resonance that can occur for particular values of the neutral inductance and pipe radius. This resonance will result in an increase in the system's neutral potential, which will be primarily limited by the network losses.
引用
收藏
页码:1225 / 1231
页数:7
相关论文
共 50 条
  • [2] AC potential on pipelines nearby EHV power lines due to Low Frequency Induction
    Al Shahri, Ahmed S.
    Nair, Nirmal-Kumar C.
    2015 AUSTRALASIAN UNIVERSITIES POWER ENGINEERING CONFERENCE (AUPEC), 2015,
  • [3] A Neural Network Approach for the Inductive Coupling between Overhead Power Lines and Nearby Metallic Pipelines
    Czumbil, Levente
    Micu, Dan Doru
    Stet, Denisa
    Ceclan, Andrei
    2016 INTERNATIONAL SYMPOSIUM ON FUNDAMENTALS OF ELECTRICAL ENGINEERING (ISFEE), 2016,
  • [4] Computation of the capacitive coupling in conductors installed nearby AC power lines
    Al-Badi, A. H.
    Salam, M. A.
    2006 IEEE/PES TRANSMISSION & DISTRIBUTION CONFERENCE & EXPOSITION: LATIN AMERICA, VOLS 1-3, 2006, : 1404 - +
  • [5] Factors Affecting Induced Voltages on Underground Pipelines due to Inductive Coupling with Nearby Transmission Lines
    Wang, Chenyang
    Liang, Xiaodong
    Freschi, Fabio
    2019 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING, 2019,
  • [6] Analysis of the electromagnetic influences of overhead lines on nearby pipelines
    Janda, Zbynek
    Nohac, Karel
    PROCEEDINGS OF THE 2015 16TH INTERNATIONAL SCIENTIFIC CONFERENCE ON ELECTRIC POWER ENGINEERING (EPE), 2015, : 52 - 55
  • [7] Investigation of Factors Affecting Induced Voltages on Underground Pipelines Due to Inductive Coupling With Nearby Transmission Lines
    Wang, Chenyang
    Liang, Xiaodong
    Freschi, Fabio
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2020, 56 (02) : 1266 - 1274
  • [8] Impact of Capacitive current of EHV/UHV lines on Current Differential Protection
    Rane, P. S.
    Jawale, R. D.
    Bhaisare, S. D.
    Debre, P. D.
    2016 INTERNATIONAL CONFERENCE ON ENERGY EFFICIENT TECHNOLOGIES FOR SUSTAINABILITY (ICEETS), 2016, : 372 - 376
  • [9] Capacitive current compensation method for differential protection of EHV/UHV lines
    Liu, Kai
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2011, 31 (08): : 94 - 98
  • [10] Electromagnetic Field Interference between High Voltage Transmission Lines and Nearby Metallic Gas Pipelines
    El-Refaie, El-Sayed Mohamed
    Ahmed, AbdEl-Latif Sayed
    Mohamed, Sabry Mousa
    Gaber, Hossam Mohamed
    2017 NINETEENTH INTERNATIONAL MIDDLE-EAST POWER SYSTEMS CONFERENCE (MEPCON), 2017, : 332 - 336