Direct measurement and analytical modeling of scatter in portal imaging

被引:45
作者
Spies, L [1 ]
Evans, PM
Partridge, M
Hansen, VN
Bortfeld, T
机构
[1] Deutsch Krebsforschungszentrum, D-69120 Heidelberg, Germany
[2] Royal Marsden Hosp NHS Trust, Sutton SM2 5PT, Surrey, England
[3] Inst Canc Res, Joint Dept Phys, Sutton SM2 5PT, Surrey, England
关键词
portal imaging; Monte Carlo simulations; scatter model;
D O I
10.1118/1.598914
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In this study a direct measurement of scatter in portal imaging for various air Saps and scatterer thicknesses at a beam energy of 6 MV is presented. The experimental data are compared with results from a Monte Carlo (MC) scatter model. In the regime where the air gap is larger than 9.3 cm the MC and the experiment agree. Based on this MC model an analytical model is developed, which takes all important interaction processes into account. It comprises a rigorous treatment of first order scattering and an estimation of photons scattered more than once within the phantom. This estimation is based on the assumption that higher order scattering can be considered as isotropically distributed around a certain scatter origin located in the midplane of the phantom. It is found that relative deviations between the MC model and the analytical model are of 2% to 3% in regions where scattering is very large. (C) 2000 American Association of Physicists in Medicine. [S0094-2405(00)01203-7].
引用
收藏
页码:462 / 471
页数:10
相关论文
共 31 条
[1]  
[Anonymous], 265 SLAC STANF U
[2]  
BERGER MJ, 1987, 873697 NBSIR
[3]   Two-dimensional exit dosimetry using a liquid-filled electronic portal imaging device and a convolution model [J].
Boellaard, R ;
vanHerk, M ;
Uiterwaal, H ;
Mijnheer, B .
RADIOTHERAPY AND ONCOLOGY, 1997, 44 (02) :149-157
[4]   First clinical tests using a liquid-filled electronic portal imaging device and a convolution model for the verification of the midplane dose [J].
Boellaard, R ;
van Herk, M ;
Uiterwaal, H ;
Mijnheer, B .
RADIOTHERAPY AND ONCOLOGY, 1998, 47 (03) :303-312
[5]   The dose response relationship of a liquid-filled electronic portal imaging device [J].
Boellaard, R ;
vanHerk, M ;
Mijnheer, BJ .
MEDICAL PHYSICS, 1996, 23 (09) :1601-1611
[6]   A convolution model to convert transmission dose images to exit dose distributions [J].
Boellaard, R ;
vanHerk, M ;
Mijnheer, BJ .
MEDICAL PHYSICS, 1997, 24 (02) :189-199
[7]   DESIGN OF COMPENSATORS FOR BREAST RADIOTHERAPY USING ELECTRONIC PORTAL IMAGING [J].
EVANS, PM ;
HANSEN, VN ;
MAYLES, WPM ;
SWINDELL, W ;
TORR, M ;
YARNOLD, JR .
RADIOTHERAPY AND ONCOLOGY, 1995, 37 (01) :43-54
[8]   Practical implementation of compensators in breast radiotherapy [J].
Evans, PM ;
Donovan, EM ;
Fenton, N ;
Hansen, VN ;
Moore, I ;
Partridge, M ;
Reise, S ;
Suter, B ;
Symonds-Tayler, JRN ;
Yarnold, JR .
RADIOTHERAPY AND ONCOLOGY, 1998, 49 (03) :255-265
[9]   Extraction of primary signal from EPIDs using only forward convolution [J].
Hansen, VN ;
Swindell, W ;
Evans, PM .
MEDICAL PHYSICS, 1997, 24 (09) :1477-1484
[10]   The application of transit dosimetry to precision radiotherapy [J].
Hansen, VN ;
Evans, PM ;
Swindell, W .
MEDICAL PHYSICS, 1996, 23 (05) :713-721