Using UVC Light-Emitting Diodes at Wavelengths of 266 to 279 Nanometers To Inactivate Foodborne Pathogens and Pasteurize Sliced Cheese

被引:110
作者
Kim, Soo-Ji
Kim, Do-Kyun
Kang, Dong-Hyun [1 ]
机构
[1] Seoul Natl Univ, Ctr Food & Bioconvergence, Dept Agr Biotechnol, Dept Food & Anim Biotechnol, Seoul, South Korea
基金
新加坡国家研究基金会;
关键词
LISTERIA-MONOCYTOGENES; WATER; MICROORGANISMS; TECHNOLOGY; SURFACE; O157H7;
D O I
10.1128/AEM.02092-15
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
UVC light is a widely used sterilization technology. However, UV lamps have several limitations, including low activity at refrigeration temperatures, a long warm-up time, and risk of mercury exposure. UV-type lamps only emit light at 254 nm, so as an alternative, UV light-emitting diodes (UV-LEDs) which can produce the desired wavelengths have been developed. In this study, we validated the inactivation efficacy of UV-LEDs by wavelength and compared the results to those of conventional UV lamps. Selective media inoculated with Escherichia coli O157:H7, Salmonella enterica serovar Typhimurium, and Listeria monocytogenes were irradiated using UV-LEDs at 266, 270, 275, and 279 nm in the UVC spectrum at 0.1, 0.2, 0.5, and 0.7 mJ/cm(2), respectively. The radiation intensity of the UV-LEDs was about 4 mu W/cm(2), and UV lamps were covered with polypropylene films to adjust the light intensity similar to those of UV-LEDs. In addition, we applied UV-LED to sliced cheese at doses of 1, 2, and 3 mJ/cm(2). Our results showed that inactivation rates after UV-LED treatment were significantly different (P <0.05) from those of UV lamps at a similar intensity. On microbiological media, UV-LED treatments at 266 and 270 nm showed significantly different (P < 0.05) inactivation effects than other wavelength modules. For sliced cheeses, 4- to 5-log reductions occurred after treatment at 3 mJ/cm(2) for all three pathogens, with negligible generation of injured cells.
引用
收藏
页码:11 / 17
页数:7
相关论文
共 25 条
[1]  
[Anonymous], LIST OUTBR
[2]   Resistance of the genome of Escherichia coli and Listeria monocytogenes to irradiation evaluated by the induction of cyclobutane pyrimidine dimers and 6-4 photoproducts using gamma and UV-C radiations [J].
Beauchamp, S. ;
Lacroix, M. .
RADIATION PHYSICS AND CHEMISTRY, 2012, 81 (08) :1193-1197
[3]   Standardization of methods for fluence (UV dose) determination in bench-scale UV experiments [J].
Bolton, JR ;
Linden, KG .
JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 2003, 129 (03) :209-215
[4]   Decontamination of Hard Cheeses by Pulsed UV Light [J].
Can, Fidan O. ;
Demirci, Ali ;
Puri, Virendra M. ;
Gourama, Hassan .
JOURNAL OF FOOD PROTECTION, 2014, 77 (10) :1723-1731
[5]  
CDC, 2010, MULT OUTBR ESCH COL
[6]  
CDC, 2013, LIST AND FOOD
[7]  
CDC, 1998, SALM ASS CHEES CONS
[8]  
CDC, 2008, OUTBR MULT RES SALM
[9]   Effect of coupled UV-A and UV-C LEDs on both microbiological and chemical pollution of urban wastewaters [J].
Chevremont, A. -C. ;
Farnet, A. -M. ;
Coulomb, B. ;
Boudenne, J. -L. .
SCIENCE OF THE TOTAL ENVIRONMENT, 2012, 426 :304-310
[10]   The combined effects of ultraviolet-C irradiation and modified atmosphere packaging for inactivating Salmonella enterica serovar Typhimurium and extending the shelf life of cherry tomatoes during cold storage [J].
Choi, Dong Soo ;
Park, Seok Ho ;
Choi, Seung Ryul ;
Kim, Jin Se ;
Chun, Ho Hyun .
FOOD PACKAGING AND SHELF LIFE, 2015, 3 :19-30