Ultrathin-strut biodegradable polymer versus durable polymer drug-eluting stents: a meta-analysis

被引:12
作者
Monjur, Mohammad Riashad [1 ,2 ]
Said, Christian F. [1 ]
Bamford, Paul [1 ,2 ]
Parkinson, Michael [1 ]
Szirt, Richard [3 ]
Ford, Thomas [1 ,2 ,4 ]
机构
[1] Cent Coast Local Hlth Dist, Dept Cardiol, Gosford, NSW, Australia
[2] Univ Newcastle, Fac Hlth & Med, Callaghan, NSW, Australia
[3] St George Hosp, Dept Cardiol, Sydney, NSW, Australia
[4] Univ Glasgow, Inst Cardiovasc & Med Sci, Glasgow, Lanark, Scotland
来源
OPEN HEART | 2020年 / 7卷 / 02期
关键词
coronary artery disease; interventional cardiology; coronary intervention (PCI); coronary stenting; acute coronary syndrome; PERIPROCEDURAL MYOCARDIAL-INFARCTION; 5-YEAR OUTCOMES; THIN-STRUT; MULTICENTER; IV;
D O I
10.1136/openhrt-2020-001394
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives Determine whether an ultrathin biodegradable polymer sirolimus-eluting stent ('Orsiro'-BP-SES) has clinical benefits over second-generation durable polymer drug-eluting stents (DP-DES). Methods We conducted a prospective systematic review and meta-analysis of randomised clinical trials comparing Orsiro BP-SES against DP-DES (PROSPERO Registration: CRD42019147136). The primary outcome was target lesion failure (TLF): composite of cardiac death, target vessel myocardial infarction (TVMI) and clinically indicated target lesion revascularisation (TLR)) evaluated at the longest available follow-up. Results Nine trials randomised 11 302 patients to either Orsiro BP-SES or DP-DES. At mean weighted follow-up of 2.8 years, the primary outcome (TLF) occurred in 501 of 6089 (8.2%) participants with BP-SES compared with 495 of 5213 (9.5%) participants with DP-DES. This equates to an absolute risk reduction of 1.3% in TLF in favour of Orsiro BP-SES (OR 0.82; 95% CI 0.69 to 0.98; p=0.03). This was driven by a reduction in TVMI (OR 0.80; 95% CI 0.65 to 0.98; p=0.03). There were no significant differences in other clinical endpoints: cardiac death, TLR and stent thrombosis. Conclusion The Orsiro BP-SES shows promising clinical outcomes in patients undergoing percutaneous coronary intervention compared with contemporary second-generation DES at a short to medium term follow-up. More research is warranted to evaluate performance over a longer follow-up period and in different clinical and lesion subsets.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Durable Polymer Versus Biodegradable Polymer Drug-Eluting Stents After Percutaneous Coronary Intervention in Patients with Acute Coronary Syndrome The HOST-REDUCE-POLYTECH-ACS Trial
    Kim, Hyo-Soo
    Kang, Jeehoon
    Hwang, Doyeon
    Han, Jung-Kyu
    Yang, Han-Mo
    Kang, Hyun-Jae
    Koo, Bon-Kwon
    Kim, Seok Yeon
    Park, Keun-Ho
    Rha, Seung-Woon
    Shin, Won-Yong
    Lim, Hong-Seok
    Park, Kyungil
    Park, Kyung Woo
    CIRCULATION, 2021, 143 (11) : 1081 - 1091
  • [42] Coating irregularities of durable polymer-based drug-eluting stents as assessed by scanning electron microscopy
    Basalus, Mounir W. Z.
    Ankone, Marc J. K.
    van Houwelingen, K. Gert
    de Man, Frits H. A. F.
    von Birgelen, Clemens
    EUROINTERVENTION, 2009, 5 (01) : 157 - 165
  • [43] Endothelial Barrier Protein Expression in Biodegradable Polymer Sirolimus-Eluting Versus Durable Polymer Everolimus-Eluting Metallic Stents
    Mori, Hiroyoshi
    Cheng, Qi
    Lutter, Christoph
    Smith, Samantha
    Guo, Liang
    Kutyna, Matthew
    Torii, Sho
    Harari, Emanuel
    Acampado, Eduardo
    Joner, Michael
    Kolodgie, Frank D.
    Virmani, Renu
    Finn, Aloke V.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (23) : 2375 - +
  • [44] Clinical Outcomes of Biodegradable versus Durable Polymer Drug Eluting Stents in Rotational Atherectomy: Results from ROCK Registry
    Kim, Kyung An
    Her, Sung-Ho
    Lee, Kyusup
    Choi, Ik Jun
    Lee, Jae-Hwan
    Lee, Jang Hoon
    Lee, Sang Rok
    Lee, Pil Hyung
    Lee, Seung-Whan
    Yoo, Ki Dong
    Lee, Su Nam
    Jang, Won Young
    Moon, Donggyu
    Moon, Keon-Woong
    Yun, Kyeong Ho
    Lee, Hyun-Jong
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (21)
  • [45] Clinical performance of drug-eluting stents with biodegradable polymeric coating: a meta-analysis and systematic review
    Ahmed, Tarek A. N.
    Bergheanu, Sandrin C.
    Stijnen, Theo
    Plevier, Josepha W. M.
    Quax, Paul H. A.
    Jukema, J. Wouter
    EUROINTERVENTION, 2011, 7 (04) : 505 - 516
  • [46] Drug-eluting balloons versus drug-eluting stents for the management of in-stent restenosis: A meta-analysis of randomized and observational studies
    Wang, Yanwei
    Lou, Xinmin
    Xu, Xiaomin
    Zhu, Jianhua
    Shang, Yunpeng
    JOURNAL OF CARDIOLOGY, 2017, 70 (5-6) : 446 - 453
  • [47] Detailed analysis of polymer response to delivery balloon expansion of drug-eluting stents versus bare metal stents
    Denardo, Scott J.
    Carpinone, Paul L.
    Vock, David M.
    Tcheng, James E.
    Phillips, Harry R., III
    Willenberg, Bradley J.
    Batich, Christopher D.
    Pepine, Carl J.
    EUROINTERVENTION, 2013, 9 (03) : 389 - 397
  • [48] Procedural Performance of Ultrathin, Biodegradable Polymer-Coated Stents Versus Durable Polymer-Coated Stents Based on Intracoronary Imaging
    des Plantes, Annemieke C. Ziedses
    Neleman, Tara
    Forero, Maria N. Tovar
    Visser, Leon
    Scoccia, Alessandra
    Groenland, Frederik T. W.
    Ligthart, Jurgen M. R.
    Boersma, Eric
    Nuis, Rutger-Jan
    den Dekker, Wijnand K.
    Wilschut, Jeroen
    Diletti, Roberto
    Zijlstra, Felix
    Van Mieghem, Nicolas M.
    Daemen, Joost
    JOURNAL OF INVASIVE CARDIOLOGY, 2022, 34 (11) : E811 - E819
  • [49] Non-polymer drug-eluting coronary stents
    Nagavendra Kommineni
    Raju Saka
    Wahid Khan
    Abraham J. Domb
    Drug Delivery and Translational Research, 2018, 8 : 903 - 917
  • [50] Non-polymer drug-eluting coronary stents
    Kommineni, Nagavendra
    Saka, Raju
    Khan, Wahid
    Domb, Abraham J.
    DRUG DELIVERY AND TRANSLATIONAL RESEARCH, 2018, 8 (04) : 903 - 917