Vertical osteoconductivity and early bone formation of titanium-zirconium and titanium implants in a subperiosteal rabbit animal model

被引:26
|
作者
Kaemmerer, Peer W. [1 ,2 ]
Palarie, Victor [3 ]
Schiegnitz, Eik [1 ]
Hagmann, Sebastien [4 ]
Alshihri, Abdulmonem [5 ]
Al-Nawas, Bilal [1 ]
机构
[1] Univ Med Ctr Mainz, Dept Oral Maxillofacial & Plast Surg, D-55131 Mainz, Germany
[2] Harvard Univ, Sch Med, Boston, MA USA
[3] Univ Chisinau, Dept Oral & Maxillofacial Surg, Kishinev, Moldova
[4] Heidelberg Univ, Dept Orthoped, Heidelberg, Germany
[5] Harvard Univ, Sch Dent Med, Dept Restorat & Biomat Sci, Boston, MA 02115 USA
关键词
SLA" surface; animal model; Roxolid implant; vertical osteoconductivity; ETCHED SLA SURFACE; CLINICAL-EVALUATION; DENTAL IMPLANT; SMALL-DIAMETER; APPOSITION; RELEASE; ALLOY;
D O I
10.1111/clr.12175
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The aim of this pilot study was to evaluate the vertical osteoconductive and osteointegrative dynamics around titanium-zirconium (TiZr) implants compared to titanium (Ti) implants. Materials and methods: In a split-leg design, 12 TiZr-SLActive and 12 Ti-SLActive implants were inserted 3 mm above bone level in the proximal tibia of 12 rabbits. Full periosteal flaps were repositioned to cover the site. Specimens were obtained after 10, 20 and 30 days (each n = 4 per group). Histomorphometric measurements included percentage of linear bone fill (PLF; %), new marginal vertical bone height (VBH; mm) and vertical bone-to-implant contact (vBIC; %). Statistical analysis was performed with the nonparametric F1_LD_F1 model to compare the two groups at the different time points. Results: After 10 days, mean PLF was 7.7% (standard deviation (SD): 5.3) for TiZr and 17.6 (SD: 8.3) for Ti. Mean VBH was 0.35 mm (SD: 0.15) and 0.78 mm (SD: 0.4) for TiZr and Ti, respectively; mean vBIC was 24.4% (SD: 41) for TiZr and 53% (SD: 28.9) for Ti samples. The differences were significant for all parameters (PLF: P = 0.021; VBH: P = 0.009; vBIC: P = 0.011). After 20 days, mean PLF was 44.3% (SD: 26.3) for TIZr and 46.2% (SD: 21.3) for Ti implants. TiZr showed a mean VBH of 1.73 mm (SD: 1) and 1.8 mm (SD: 0.6) for Ti samples. Mean vBIC had values of 48.3% (SD: 23.7) and 68.7% (SD: 35.5) for TiZr and Ti, respectively (PLF: P = 0.78; VBH: P = 0.58; vBIC: P = 0.47). At the point of 30 days, mean PLF values were 23.7% (SD: 3.8) for TiZr and 28.9% (SD: 21.7) for Ti samples; mean for VBH in TiZr samples was 0.65 mm (SD: 0.39) and 1.7 mm (SD: 1.1) for Ti ones. Finally, mean vBIC was 28.3% (SD: 19.3) and 54.4% (SD: 26.5) for TiZr and Ti samples, respectively (PLF: P = 0.1; VBH: P = 0.088; vBIC: P = 0.089). Conclusions: A significant delay in vertical osteoconductivity at the earliest time point under examination was seen for TiZr implants when compared to their Ti counterparts. For the later points, TiZr as well as Ti implants demonstrated comparable values in this animal model. The longterm osteogenic surface properties of equally pretreated TiZr dental implants are therefore similar to those of Ti implants in vivo.
引用
收藏
页码:774 / 780
页数:7
相关论文
共 50 条
  • [11] The Performance of Titanium-Zirconium Implants in the Elderly: A Biomechanical Comparative Study in the Minipig
    Wen, Bo
    Chen, Jiang
    Dard, Michel
    Cai, Zhiyu
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2016, 18 (06) : 1200 - 1209
  • [12] Macrophage behavior and interplay with gingival fibroblasts cultured on six commercially available titanium, zirconium, and titanium-zirconium dental implants
    Yulan Wang
    Yufeng Zhang
    Anton Sculean
    Dieter D Bosshardt
    Richard J Miron
    Clinical Oral Investigations, 2019, 23 : 3219 - 3227
  • [13] Histomorphometric and histologic evaluation of titanium-zirconium (aTiZr) implants with anodized surfaces
    Sharma, Ajay
    McQuillan, A. James
    Shibata, Yo
    Sharma, Lavanya A.
    Waddell, John Neil
    Duncan, Warwick John
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2016, 27 (05)
  • [14] Vertical osteoconductivity of sputtered hydroxyapatite-coated mini titanium implants after dura mater elevation: Rabbit calvarial model
    Wang, Xin
    Zakaria, Osama
    Madi, Marwa
    Kasugai, Shohei
    JOURNAL OF TISSUE ENGINEERING, 2015, 6
  • [15] Structure of the interface between rabbit cortical bone and implants of gold, zirconium and titanium
    Thomsen, P
    Larsson, C
    Ericson, LE
    Sennerby, L
    Lausmaa, J
    Kasemo, B
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1997, 8 (11) : 653 - 665
  • [16] Structure of the interface between rabbit cortical bone and implants of gold, zirconium and titanium
    P THOMSEN
    C LARSSON
    L. E ERICSON
    L SENNERBY
    J LAUSMAA
    B KASEMO
    Journal of Materials Science: Materials in Medicine, 1997, 8 : 653 - 665
  • [17] Evaluation of New Bone Formation and Osseointegration Around Subperiosteal Titanium Implants with Histometry and Nanoindentation
    Claffey, Noel
    Bashara, Haitham
    O'Reilly, Peter
    Polyzois, Ioannis
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2015, 30 (05) : 1004 - 1010
  • [18] Impact of plaque accumulation on the osseointegration of titanium-zirconium alloy and titanium implants. A histological and immunohistochemical analysis
    Schwarz, Frank
    Mihatovic, Ilja
    Golubovic, Vladimir
    Bradu, Sebastian
    Sager, Martin
    Becker, Juergen
    CLINICAL ORAL IMPLANTS RESEARCH, 2015, 26 (11) : 1281 - 1287
  • [19] Comparison with the osteoconductivity and bone-bonding ability of the iodine supported titanium, titanium with porous oxide layer and the titanium alloy in the rabbit model
    Taga, Tadashi
    Kabata, Tamon
    Kajino, Yoshitomo
    Inoue, Daisuke
    Ohmori, Takaaki
    Yamamoto, Takashi
    Takagi, Tomoharu
    Tsuchiya, Hiroyuki
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2018, 23 (03) : 585 - 591
  • [20] INTERFACE ANALYSIS OF TITANIUM AND ZIRCONIUM BONE IMPLANTS
    ALBREKTSSON, T
    HANSSON, HA
    IVARSSON, B
    BIOMATERIALS, 1985, 6 (02) : 97 - 101