Depth-of-Field of the Accommodating Eye

被引:35
作者
Bernal-Molina, Paula [1 ,2 ]
Montes-Mico, Robert [1 ]
Legras, Richard [3 ]
Lopez-Gil, Norberto [2 ]
机构
[1] Univ Valencia, Grp Invest Optometria, Valencia, Spain
[2] Univ Murcia, Grp Ciencias Vis, E-30100 Murcia, Spain
[3] Univ Paris 11, Orsay, France
关键词
depth-of-focus; depth-of-field; accommodation; aberrations; spherical aberration; adaptive optics; accommodative lag; pupil; accommodation response; SPHERICAL-ABERRATION; ADAPTIVE OPTICS; INTRAOCULAR LENSES; IMAGE QUALITY; FOCUS; POPULATION; PRESBYOPIA; DEFOCUS; IMPACT;
D O I
10.1097/OPX.0000000000000365
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To obtain experimental values of the depth-of-field (DOFi) of the human eye for different accommodative states. Methods First, the monochromatic ocular wavefront of seven eyes from young subjects (mean [SD] age, 29.7 [7.7] years) was measured at eight different accommodative demands (ADs) (from -1 to 6 diopters [D] in steps of 1 D). Then, in a second part, accommodation was paralyzed and an adaptive optics system was used to correct the aberrations of the paralyzed eye and to simulate, with the aid of an artificial pupil, the wavefront of the accommodated eye. The simulation was performed for each AD measured in the first part of the experiment. A Badal system was used to modify the stimulus vergence so as to obtain three repeated measurements of the subjective DOFi, based on the criterion of an objectionable blur. Results When increasing AD from 0 to 6 D, the mean intersubject pupil diameter and DOFi changed from 5.70 to 4.62 mm and from 0.85 +/- 0.26 D to 1.07 +/- 0.19 D, respectively. All subjects presented a similar DOFi for all AD (intrasubject SD never exceeded 0.23 D). Paraxial accommodation response showed a lag that increased with the AD. For the lowest (0 D) and the highest (6 D) values of AD, the refractive state of the eye was close to the nearest and furthermost ends of the DOFi, respectively. Conclusions The visual system takes advantage of the DOFi to change the refractive state less than necessary to form the paraxial image at the retina when it comes to focusing a near target (5 to 6 D of AD). This indicates that the main purpose of accommodation is not to maximize retinal image quality but to form one that is good enough.
引用
收藏
页码:1208 / 1214
页数:7
相关论文
共 35 条
[1]   MEASUREMENT OF MONOCHROMATIC OCULAR ABERRATIONS OF HUMAN EYES AS A FUNCTION OF ACCOMMODATION BY THE HOWLAND ABERROSCOPE TECHNIQUE [J].
ATCHISON, DA ;
COLLINS, MJ ;
WILDSOET, CF ;
CHRISTENSEN, J ;
WATERWORTH, MD .
VISION RESEARCH, 1995, 35 (03) :313-323
[2]   Subjective depth-of-focus of the eye [J].
Atchison, DA ;
Charman, WN ;
Woods, RL .
OPTOMETRY AND VISION SCIENCE, 1997, 74 (07) :511-520
[3]  
Campbell FW, 1957, Opt Acta Int J Opt, V4, P157, DOI [DOI 10.1080/713826091, 10.1080/713826091]
[4]  
Castejón-Mochón JF, 2002, VISION RES, V42, P1611, DOI 10.1016/S0042-6989(02)00085-8
[5]   PUPIL DIAMETER AND DEPTH-OF-FIELD OF HUMAN EYE AS MEASURED BY LASER SPECKLE [J].
CHARMAN, WN ;
WHITEFOOT, H .
OPTICA ACTA, 1977, 24 (12) :1211-1216
[6]  
CHARMAN WN, 1995, HDB OPTICS FUNDAMENT, V1, P3
[7]   A population study on changes in wave aberrations with accommodation [J].
Cheng, H ;
Barnett, JK ;
Vilupuru, AS ;
Marsack, JD ;
Kasthurirangan, S ;
Applegate, RA ;
Roorda, A .
JOURNAL OF VISION, 2004, 4 (04) :272-280
[8]   Visual Impact of Zernike and Seidel Forms of Monochromatic Aberrations [J].
Cheng, Xu ;
Bradley, Arthur ;
Ravikumar, Sowmya ;
Thibos, Larry N. .
OPTOMETRY AND VISION SCIENCE, 2010, 87 (05) :300-312
[9]   Optical surface optimization for the correction of presbyopia [J].
Dai, Guang-Ming .
APPLIED OPTICS, 2006, 45 (17) :4184-4195
[10]   Adaptive optics with a magnetic deformable mirror:: applications in the human eye [J].
Fernández, Enrique J. ;
Vabre, Laurent ;
Hermann, Boris ;
Unterhuber, Angelika ;
Povazay, Boris ;
Drexler, Wolfgang .
OPTICS EXPRESS, 2006, 14 (20) :8900-8917