Assessment of Radiation Protection in Hand-Shielding Products With Mini C-Arm Fluoroscopy

被引:11
作者
Cantlon, Matthew B. [1 ]
Ilyas, Asif M. [2 ,3 ]
机构
[1] Orthoped & Neurosurg Specialists, Greenwich, CT USA
[2] Thomas Jefferson Univ, Rothman Inst, Philadelphia, PA USA
[3] Thomas Jefferson Univ, Rothman Inst, Dept Orthoped, 925 Chestnut St,5th Floor, Philadelphia, PA 19107 USA
来源
HAND-AMERICAN ASSOCIATION FOR HAND SURGERY | 2021年 / 16卷 / 04期
关键词
fluoroscopy; radiation; exposure; shielding; protection; EXPOSURE; SURGEONS; INJURY;
D O I
10.1177/1558944719865937
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Previous studies have highlighted the particular risk of radiation exposure to the surgeon's hands with intraoperative fluoroscopy. Although evidence exists that shielding equipment for the hands reduces exposure, the extent of protection is not well understood. Therefore, we set out to determine the degree to which radiation exposure to the surgeon's hands is decreased with hand-shielding products. Methods: An anthropomorphic model was positioned to simulate a surgeon sitting at a hand table. Thermoluminescent dosimeters were placed on the proximal phalanx of each index finger. The right index finger dosimeter was covered with a standard polyisoprene surgical glove (control arm), whereas the left index finger dosimeter was covered with commercially available hand-shielding products (study arm): lead-free metal-oxide gloves, leaded gloves, and radiation-attenuating cream. Mini fluoroscope position, configuration, and settings were standardized. The model was scanned for 15 continuous minutes in each test run, and each comparative arm was run 3 times. Results: The mean radiation dose absorbed by the control and variable dosimeters across all tests was 44.8 mrem (range, 30-54) and 18.6 mrem (range, 14-26), respectively. Each hand-shielding product resulted in statistically lower radiation exposure than a single polyisoprene surgical glove. Conclusions: The mean radiation exposure to the hands was significantly decreased when protected by radiation-attenuating options. Each product individually resulted in a statistically significant decrease in hand exposure compared with the control. We recommend that in addition to efforts to decrease radiation exposure, surgeons consider routine use of hand-shielding products when using mini c-arm fluoroscopy.
引用
收藏
页码:505 / 510
页数:6
相关论文
共 15 条
[1]   Radiation exposure in hand surgery: Mini versus standard C-arm [J].
Athwal, GS ;
Bueno, RA ;
Wolfe, SW .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2005, 30A (06) :1310-1316
[2]   Radiation injury and the hand surgeon [J].
Chambers, James A. ;
Long, James N. .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2008, 33A (04) :601-611
[3]   Fluoroscopy-induced chronic radiation skin injury -: A disease perhaps often overloohed [J].
Frazier, Thomas H. ;
Richardson, Jeffrey B. ;
Fabre, Vilma C. ;
Callen, Jeffrey P. .
ARCHIVES OF DERMATOLOGY, 2007, 143 (05) :637-640
[4]   HISTORY, CURRENT STATUS, AND TRENDS OF RADIATION PROTECTION STANDARDS [J].
HENDEE, WR .
MEDICAL PHYSICS, 1993, 20 (05) :1303-1314
[5]  
Herscovici D, 2000, CLIN ORTHOP RELAT R, P126
[6]   Fluoroscopic Radiation Exposure Are We Protecting Ourselves Adequately? [J].
Hoffler, C. Edward ;
Ilyas, Asif M. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2015, 97A (09) :721-725
[7]  
ICRP, 2007, Ann ICRP, V37, P2, DOI DOI 10.1016/J.ICRP.2007.10.003
[8]   Increased cancer risk among surgeons in an orthopaedic hospital [J].
Mastrangelo, G ;
Fedeli, U ;
Fadda, E ;
Giovanazzi, A ;
Scoizzato, L ;
Saia, B .
OCCUPATIONAL MEDICINE-OXFORD, 2005, 55 (06) :498-500
[9]   GENETIC-EFFECTS OF THE ATOMIC BOMBS - A REAPPRAISAL [J].
SCHULL, WJ ;
OTAKE, M ;
NEEL, JV .
SCIENCE, 1981, 213 (4513) :1220-1227
[10]   Radiation exposure to the hands from mini C-arm fluoroscopy [J].
Singer, G .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2005, 30A (04) :795-797