Techno-economic assessment and optimization of a hybrid renewable co-supply of electricity, heat and hydrogen system to enhance performance by recovering excess electricity for a large energy consumer

被引:160
作者
Akhtari, Mohammad Reza [1 ]
Baneshi, Mehdi [2 ]
机构
[1] Shiraz Univ Technol, Dept Mech & Aerosp Engn, Shiraz 7155713876, Iran
[2] Shiraz Univ, Sch Mech Engn, Shiraz 7193616548, Iran
关键词
Hybrid system; Thermal load controller; HRES; Cost optimization; Renewable energy; Hydrogen refueling; REFUELING STATION; RURAL ELECTRIFICATION; GENERATION SYSTEMS; POWER-GENERATION; OPTIMAL-DESIGN; FEASIBILITY; DIESEL; SOLAR; BATTERY; ISLAND;
D O I
10.1016/j.enconman.2019.03.067
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study attempts to optimize and examine the techno-economic feasibility of off-grid hybrid renewable energy systems (HRES) to satisfy simultaneously electric, heat and hydrogen load of a large energy consumer. An innovative method is adopted so as to recover surplus electricity to generate heat and cut emissions. The system is comprised of solar panels, wind turbine, diesel generator, electrolyzer and boiler to supply 9910 kWh/day of electricity, 14 kg/day of hydrogen and thermal energy in five different major cities in Iran, namely Bandar Abbas, Shiraz, Tabriz, Tehran and Yazd. These figures are computed on average and the thermal load differs according to yearly weather temperature, which are 75, 22, 2000, 5200, 2200 and 1800 kWh/day respectively. To serve this purpose, HOMER Pro software was used and thermal load controller (TLC) (including electric boiler) was added to generate thermal energy by converting excess electricity of renewable energy production. Thus, a decrease in conventional fuel consumption, emissions and cost of energy (COE), as well as an increase in the renewable fraction of HRES without increasing project's size would be achievable. To meet peak demand and avoid intermittent behavior of HRES, a 1000 kW generator was picked up. Results indicate that recovering extra electricity can enhance renewable fraction by up to 35% and bring down COE and exhausted CO2 by 7.1% and 10.6% respectively, which highlight the necessity of TLC in HRES, chiefly in off-grid systems.
引用
收藏
页码:131 / 141
页数:11
相关论文
共 55 条
[1]   Overall performance index for hybrid power plants [J].
Al-Sharafi, Abdullah ;
Sahin, Ahmet Z. ;
Yilbas, Bekir S. .
ENERGY CONVERSION AND MANAGEMENT, 2015, 100 :103-116
[2]   Assessment of wind energy in Iran: A review [J].
Alamdari, P. ;
Nematollahi, O. ;
Mirhosseini, M. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2012, 16 (01) :836-860
[3]  
[Anonymous], CONTRACT
[4]  
[Anonymous], ELSEVIER
[5]  
[Anonymous], 2016, HOMER PROUSER MANUAL
[6]  
[Anonymous], COST ANAL HYBRID POW
[7]  
[Anonymous], 2008, MODELING COST EFFECT
[8]  
[Anonymous], 2018, AN OUTL 2040
[9]  
[Anonymous], HYBRID RENEWABLE DIE
[10]  
[Anonymous], 1991, SOLAR ENG THERMAL PR