Detection of Atrial Fibrillation Using a Modified Microlife Blood Pressure Monitor

被引:99
作者
Wiesel, Joseph [1 ]
Fitzig, Lorenzo [1 ]
Herschman, Yehuda [2 ]
Messineo, Frank C. [1 ]
机构
[1] New York Hosp Queens, Dept Med, Flushing, NY USA
[2] Yeshiva Univ, Yeshiva Coll, New York, NY 10033 USA
关键词
D O I
10.1038/ajh.2009.98
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
BACKGROUND Hypertension is a major risk factor for the development of atrial fibrillation (AF) and for stroke due to AF. Asymptomatic AF can result in a stroke, in patients with risk factors, if it is not detected and treated appropriately. This study evaluated the sensitivity and specificity of an automatic oscillometric sphygmomanometer designed to detect AF. METHODS The sphygmomanometer incorporates an algorithm for detecting AF while reducing false positive readings due to premature beats. A total of 405 unselected outpatients seen in two cardiology offices were evaluated by taking three sequential device readings and one electrocardiogram (EKG) on each patient. RESULTS For detecting AF, the sensitivity was 95% and the specificity 86% with a positive predictive value of 68% and a negative predictive value of 98% for single device readings. For the three sequential device readings grouped together, the sensitivity was 97% and the specificity was 89%. The device correctly categorized most of the non-AF, abnormal rhythms. The specificity for those in sinus rhythm was 97%. CONCLUSIONS This device is able to detect AF with high sensitivity and specificity. Use of this device by patients who monitor their blood pressure at home may help detect asymptomatic AF and allow for treatment prior to the development of a stroke. Am J Hypertens 2009; 22:848-852 (C) 2009 American Journal of Hypertension, Ltd.
引用
收藏
页码:848 / 852
页数:5
相关论文
共 16 条
[1]  
Atrial fibrillation investigators, 1994, ARCH INTERN MED, V154, P2254
[2]  
Efron B., 1993, INTRO BOOTSTRAP, DOI 10.1007/978-1-4899-4541-9
[3]   ACC/AHA/ESC 2006 Guidelines for the Management of Patients With Atrial Fibrillation A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines and the European Society of Cardiology Committee for Practice Guidelines (Writing Committee to Revise the 2001 Guidelines for the Management of Patients With Atrial Fibrillation) Developed in Collaboration With the European Heart Rhythm Association and the Heart Rhythm Society [J].
Fuster, Valentin ;
Ryden, Lars E. ;
Cannom, David S. ;
Crijns, Harry J. ;
Curtis, Anne B. ;
Ellenbogen, Kenneth A. ;
Halperin, Jonathan L. ;
Le Heuzey, Jean-Yves ;
Kay, G. Neal ;
Lowe, James E. ;
Olsson, S. Bertil ;
Prystowsky, Eric N. ;
Tamargo, Juan Luis ;
Wann, Samuel .
CIRCULATION, 2006, 114 (07) :E257-E354
[4]   Long-term risk of recurrent atrial fibrillation as documented by an Implantable monitoring device -: Implications for optimal patient care [J].
Israel, CW ;
Grönefeld, G ;
Ehrlich, JR ;
Li, YG ;
Hohnloser, SH .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (01) :47-52
[5]  
JOY L, 2007, STROKE, V38, P2935
[6]  
KANNEL WB, 1998, AM J CARDIOL, V0082
[7]  
LAUPACIS A, 1994, ARCH INTERN MED, V154, P1449
[8]   NEWLY-DIAGNOSED ATRIAL-FIBRILLATION AND ACUTE STROKE - THE FRAMINGHAM-STUDY [J].
LIN, HJ ;
WOLF, PA ;
BENJAMIN, EJ ;
BELANGER, AJ ;
DAGOSTINO, RB .
STROKE, 1995, 26 (09) :1527-1530
[9]  
Mancia G, 2007, EUR HEART J, V28, P1462, DOI [10.1093/eurheartj/ehm236, 10.1093/eurheartj/eht151]
[10]  
Munschauer Frederick E 3rd, 2004, J Stroke Cerebrovasc Dis, V13, P208, DOI 10.1016/j.jstrokecerebrovasdis.2004.08.001