Radiation-field mapping of insect irradiation canisters

被引:6
作者
Walker, ML [1 ]
McLaughlin, WL [1 ]
Puhl, JM [1 ]
Gomes, P [1 ]
机构
[1] USDA,ANIM & PLANT HLTH INSPECT SERV,RIVERDALE,MD 20737
关键词
D O I
10.1016/S0969-8043(96)00051-6
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Dosimetry methods developed at NIST for mapping ionizing radiation fields were applied to canisters used in Cs-137 dry-source irradiators designed for insect sterilization. The method of mapping the radiation fields inside of these canisters as they cycled through the gamma-ray irradiators involved the use of radiochromic films, which increase in optical density proportionately to the absorbed dose. A dosimeter film array in a cardboard phantom was designed to simulate the average insect pupae density and to map the dose within the full volume of the canister; the calibrated films were read using a laser scanning densitometer. Previously used dosimetric methods did not allow for the spatial resolution that is possible with these films. Results indicate that this dose-mapping technique is a powerful method of evaluating a variety of radiation fields of commercial radiation sources, with promising applications as a means of dose validation and quality control. Copyright (C) 1997 Published by Elsevier Science Ltd
引用
收藏
页码:117 / 125
页数:9
相关论文
共 14 条
[1]   SCREW-WORM CONTROL THROUGH RELEASE OF STERILIZED FLIES [J].
BAUMHOVER, AH ;
GRAHAM, AJ ;
BITTER, BA ;
HOPKINS, DE ;
NEW, WD ;
DUDLEY, FH ;
BUSHLAND, RC .
JOURNAL OF ECONOMIC ENTOMOLOGY, 1955, 48 (04) :462-466
[2]   STERILIZATION OF SCREW-WORM FLIES WITH X-RAYS AND GAMMA-RAYS [J].
BUSHLAND, RC ;
HOPKINS, DE .
JOURNAL OF ECONOMIC ENTOMOLOGY, 1953, 46 (04) :648-656
[3]   EXPERIMENTS WITH SCREW-WORM FLIES STERILIZED BY X-RAYS [J].
BUSHLAND, RC ;
HOPKINS, DE .
JOURNAL OF ECONOMIC ENTOMOLOGY, 1951, 44 (05) :725-731
[5]   THE USE OF GAMMA-RADIATION FOR CONTROL OR ERADICATION OF THE SCREW-WORM [J].
LINDQUIST, AW .
JOURNAL OF ECONOMIC ENTOMOLOGY, 1955, 48 (04) :467-469
[6]  
MADIGAN ER, 1992, FED REGISTER, V57, P2249
[7]   SENSITOMETRY OF THE RESPONSE OF A NEW RADIOCHROMIC FILM DOSIMETER TO GAMMA-RADIATION AND ELECTRON-BEAMS [J].
MCLAUGHLIN, WL ;
YUNDONG, C ;
SOARES, CG ;
MILLER, A ;
VANDYK, G ;
LEWIS, DF .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 302 (01) :165-176
[8]  
MCLAUGHLIN WL, 1991, BETA GAMMA, V4, P20
[9]  
MULLER HJ, 1927, Z INDUKT ABSTAMM VER, V1, P234
[10]  
Runner GA, 1916, J AGRIC RES, V6, P383