Early clinical and radiological results of total knee arthroplasty using patient-specific guides in obese patients

被引:11
作者
Anwar, Rahij [1 ]
Kini, Sunil Gurpur [1 ,2 ]
Sait, Saif [1 ]
Bruce, Warwick J. M. [1 ]
机构
[1] Sydney Private Hosp, Dept Orthopaed, Concord Repatriat Gen Hosp, Sydney, NSW, Australia
[2] Univ Coll London Hosp, Dept Orthopaed, 250 Euston Rd, London NW1 2PG, England
关键词
Obesity; Patient-specific guides; Alignment; BODY-MASS INDEX; VENOUS THROMBOEMBOLISM; INSTRUMENTATION; REPLACEMENT; ALIGNMENT; ROTATION;
D O I
10.1007/s00402-015-2399-z
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Total knee arthroplasty (TKA) is a challenging procedure in patients with a high body mass index (BMI). The aim of our study was to assess the outcome and accuracy of restoration of mechanical alignment in TKA using patient-specific guides (PSG) involving patients with high BMI. Patients with BMI of 30 or above were enrolled in the study. The mean age of the patients was 65.15 years. The study comprised of 46 males and 54 females. Total knee arthroplasty was planned after a pre-operative MRI and long leg x-ray films using customized PSG. Of the 105 knees (100 patients) in the study, average BMI was 35.42 kg/m(2) (30-56). Twenty patients (20 %) had class III obesity (a parts per thousand yen40 kg/m(2)). The average blood loss and operative time were 236.1 ml (range 50-700 ml) and 92.2 min (65-130 min), respectively. The average post-operative mechanical axis was noted to be 1.85A degrees varus (range 4A degrees valgus to 6A degrees varus). Eighty-eight patients (86.27 %) had mechanical alignment within 3A degrees of neutral. There were no adverse intraoperative events. One patient had deep infection that required a two-stage revision. The average post-operative range of motion at 1-year follow-up was 105.8A degrees (range 80A degrees-130A degrees). Patient-specific guides technology restores the coronal mechanical axis reliably in obese patients without adversely affecting outcomes. Our short-term follow-up has shown favorable outcomes. Surgeons should use these customized jigs as a guide and adjust the size of components, alignment and rotation according to normal surgical principles.
引用
收藏
页码:265 / 270
页数:6
相关论文
共 50 条
  • [41] Accuracy of CT-based patient-specific guides for total knee arthroplasty in patients with post-traumatic osteoarthritis
    Schotanus M.G.M.
    van Haaren E.H.
    Hendrickx R.P.M.
    Jansen E.J.P.
    Kort N.P.
    European Journal of Orthopaedic Surgery & Traumatology, 2015, 25 (8) : 1313 - 1320
  • [42] Patient-specific instrumentation in total knee arthroplasty: a review of the current literature
    Schoenthaler, Wolfgang
    Dauwe, Jan
    Holzer, Lukas A.
    ACTA ORTHOPAEDICA BELGICA, 2023, 89 (02): : 299 - 306
  • [43] Patient-specific instrumentation versus conventional instrumentation in total knee arthroplasty
    Chan, Warwick Chun-Wang
    Pinder, Elizabeth
    Loeffler, Mark
    JOURNAL OF ORTHOPAEDIC SURGERY, 2016, 24 (02) : 175 - 178
  • [44] Patient-Specific Instrumentation Does Not Improve Accuracy in Total Knee Arthroplasty
    Shen, Chong
    Tang, Zhi-Hong
    Hu, Jun-Zu
    Zou, Guo-Yao
    Xiao, Rong-Chi
    Yan, Dong-Xue
    ORTHOPEDICS, 2015, 38 (03) : E178 - E188
  • [45] Artificial Intelligence Based Patient-Specific Preoperative Planning Algorithm for Total Knee Arthroplasty
    Lambrechts, Adriaan
    Wirix-Speetjens, Roel
    Maes, Frederik
    Van Huffel, Sabine
    FRONTIERS IN ROBOTICS AND AI, 2022, 9
  • [46] Revision of total knee arthroplasty with the use of patient-specific instruments: an alternative surgical technique
    Leon-Munoz, Vicente J.
    Parrinello, Andrea
    Lopez-Lopez, Mirian
    Martinez-Martinez, Francisco
    Santonja-Medina, Fernando
    EXPERT REVIEW OF MEDICAL DEVICES, 2020, 17 (08) : 795 - 806
  • [47] Functional Outcome and Quality of Life after Patient-Specific Instrumentation in Total Knee Arthroplasty
    Chen, Jerry Yonggiang
    Chin, Pak Lin
    Tay, Darren Keng Jin
    Chia, Shi-Lu
    Lo, Ngai Nung
    Yeo, Seng Jin
    JOURNAL OF ARTHROPLASTY, 2015, 30 (10) : 1724 - 1728
  • [48] A Retrospective Study Comparing a Patient-specific Design Total Knee Arthroplasty With an Off-the-Shelf Design: Unexpected Catastrophic Failure Seen in the Early Patient-specific Design
    Meheux, Carlos J.
    Park, Kwan J.
    Clyburn, Terry A.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS GLOBAL RESEARCH AND REVIEWS, 2019, 3 (11):
  • [49] Patient-specific Guides Do Not Improve Accuracy in Total Knee Arthroplasty: A Prospective Randomized Controlled Trial
    Victor, Jan
    Dujardin, Jan
    Vandenneucker, Hilde
    Arnout, Nele
    Bellemans, Johan
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2014, 472 (01) : 263 - 271
  • [50] Total Knee Arthroplasty Using Patient-specific Blocks after Prior Femoral Fracture without Hardware Removal
    Vaishya, Raju
    Vijay, Vipul
    Agarwal, Amit K.
    INDIAN JOURNAL OF ORTHOPAEDICS, 2018, 52 (02) : 154 - 160