Early clinical and radiological results of total knee arthroplasty using patient-specific guides in obese patients

被引:11
|
作者
Anwar, Rahij [1 ]
Kini, Sunil Gurpur [1 ,2 ]
Sait, Saif [1 ]
Bruce, Warwick J. M. [1 ]
机构
[1] Sydney Private Hosp, Dept Orthopaed, Concord Repatriat Gen Hosp, Sydney, NSW, Australia
[2] Univ Coll London Hosp, Dept Orthopaed, 250 Euston Rd, London NW1 2PG, England
关键词
Obesity; Patient-specific guides; Alignment; BODY-MASS INDEX; VENOUS THROMBOEMBOLISM; INSTRUMENTATION; REPLACEMENT; ALIGNMENT; ROTATION;
D O I
10.1007/s00402-015-2399-z
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Total knee arthroplasty (TKA) is a challenging procedure in patients with a high body mass index (BMI). The aim of our study was to assess the outcome and accuracy of restoration of mechanical alignment in TKA using patient-specific guides (PSG) involving patients with high BMI. Patients with BMI of 30 or above were enrolled in the study. The mean age of the patients was 65.15 years. The study comprised of 46 males and 54 females. Total knee arthroplasty was planned after a pre-operative MRI and long leg x-ray films using customized PSG. Of the 105 knees (100 patients) in the study, average BMI was 35.42 kg/m(2) (30-56). Twenty patients (20 %) had class III obesity (a parts per thousand yen40 kg/m(2)). The average blood loss and operative time were 236.1 ml (range 50-700 ml) and 92.2 min (65-130 min), respectively. The average post-operative mechanical axis was noted to be 1.85A degrees varus (range 4A degrees valgus to 6A degrees varus). Eighty-eight patients (86.27 %) had mechanical alignment within 3A degrees of neutral. There were no adverse intraoperative events. One patient had deep infection that required a two-stage revision. The average post-operative range of motion at 1-year follow-up was 105.8A degrees (range 80A degrees-130A degrees). Patient-specific guides technology restores the coronal mechanical axis reliably in obese patients without adversely affecting outcomes. Our short-term follow-up has shown favorable outcomes. Surgeons should use these customized jigs as a guide and adjust the size of components, alignment and rotation according to normal surgical principles.
引用
收藏
页码:265 / 270
页数:6
相关论文
共 50 条
  • [31] Reducing Blood Loss in Bilateral Total Knee Arthroplasty with Patient-Specific Instrumentation
    Rathod, Parthiv A.
    Deshmukh, Ajit J.
    Cushner, Fred D.
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 2015, 46 (03) : 343 - +
  • [32] Rotation in total knee arthroplasty: no difference between patient-specific and conventional instrumentation
    Parratte, Sebastien
    Blanc, Guillaume
    Boussemart, Thomas
    Ollivier, Matthieu
    Le Corroller, Thomas
    Argenson, Jean-Noel
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2013, 21 (10) : 2213 - 2219
  • [33] MRI is more accurate than CT for patient-specific total knee arthroplasty
    Frye, Benjamin M.
    Najim, Amjad A.
    Adams, Joanne B.
    Berend, Keith R.
    Lombardi, Adolph V., Jr.
    KNEE, 2015, 22 (06) : 609 - 612
  • [34] Patient-Specific Instrumentation Affects Perioperative Blood Loss in Total Knee Arthroplasty
    Cucchi, Davide
    Menon, Alessandra
    Zanini, Beatrice
    Compagnoni, Riccardo
    Ferrua, Paolo
    Randelli, Pietro
    JOURNAL OF KNEE SURGERY, 2019, 32 (06) : 483 - 489
  • [35] Systematic Review of Patient-specific Instrumentation in Total Knee Arthroplasty: New but Not Improved
    Sassoon, Adam
    Nam, Denis
    Nunley, Ryan
    Barrack, Robert
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2015, 473 (01) : 151 - 158
  • [36] Intra-operative results and radiological outcome of conventional and patient-specific surgery in total knee arthroplasty: a multicentre, randomised controlled trial
    B. Boonen
    M. G. M. Schotanus
    B. Kerens
    W. van der Weegen
    R. A. M. van Drumpt
    N. P. Kort
    Knee Surgery, Sports Traumatology, Arthroscopy, 2013, 21 : 2206 - 2212
  • [37] A radiological analysis of the difference between MRI- and CT-based patient-specific matched guides for total knee arthroplasty from the same manufacturer A RANDOMISED CONTROLLED TRIAL
    Schotanus, M. G. M.
    Sollie, R.
    van Haaren, E. H.
    Hendrickx, R. P. M.
    Jansen, E. J. P.
    Kort, N. P.
    BONE & JOINT JOURNAL, 2016, 98B (06) : 786 - 792
  • [38] Revision of partial knee to total knee arthroplasty with use of patient-specific instruments results in acceptable femoral rotation
    Martijn G. M. Schotanus
    Elke Thijs
    B. Boonen
    B. Kerens
    B. Jong
    Nanne P. Kort
    Knee Surgery, Sports Traumatology, Arthroscopy, 2018, 26 : 1656 - 1661
  • [39] Functional Outcomes and Accuracy of Patient-Specific Instruments for Total Knee Arthroplasty
    Stone, Andrea H.
    Sibia, Udai S.
    MacDonald, James H.
    SURGICAL INNOVATION, 2018, 25 (05) : 470 - 475
  • [40] Patient-specific instrumentation in total ankle arthroplasty
    Mazzotti, Antonio
    Arceri, Alberto
    Zielli, Simone
    Bonelli, Simone
    Viglione, Valentina
    Faldini, Cesare
    WORLD JOURNAL OF ORTHOPEDICS, 2022, 13 (03): : 230 - 237