An Alternative Approach to Detecting Cancer Cells by Multi-Directional Fluorescence Detection System Using Cost-Effective LED and Photodiode

被引:6
作者
Cho, Kyoungrae [1 ]
Seo, Jeong-hyeok [1 ]
Heo, Gyeongyong [2 ]
Choe, Se-woon [1 ]
机构
[1] Kumoh Natl Inst Technol, Dept Med IT Convergence Engn, Gumi 39253, South Korea
[2] Dong Eui Univ, Dept Elect Engn, Busan 47340, South Korea
基金
新加坡国家研究基金会;
关键词
fluorescence detection system; light-emitting diode; photodiode; cancer cells; LIGHT-EMITTING DIODE; FLOW-CYTOMETRY;
D O I
10.3390/s19102301
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The enumeration of cellular proliferation by covering from hemocytometer to flow cytometer is an important procedure in the study of cancer development. For example, hemocytometer has been popularly employed to perform manual cell counting. It is easily achieved at a low-cost, however, manual cell counting is labor-intensive and prone to error for a large number of cells. On the other hand, flow cytometer is a highly sophisticated instrument in biomedical and clinical research fields. It provides detailed physical parameters of fluorescently labeled single cells or micro-sized particles depending on the fluorescence characteristics of the target sample. Generally, optical setup to detect fluorescence uses a laser, dichroic filter, and photomultiplier tube as a light source, optical filter, and photodetector, respectively. These components are assembled to set up an instrument to measure the amount of scattering light from the target particle; however, these components are costly, bulky, and have limitations in selecting diverse fluorescence dyes. Moreover, they require multiple refined and expensive modules such as cooling or pumping systems. Thus, alternative cost-effective components have been intensively developed. In this study, a low-cost and miniaturized fluorescence detection system is proposed, i.e., costing less than 100 US dollars, which is customizable by a 3D printer and light source/filter/sensor operating at a specific wavelength using a light-emitting diode with a photodiode, which can be freely replaceable. The fluorescence detection system can quantify multi-directional scattering lights simultaneously from the fluorescently labeled cervical cancer cells. Linear regression was applied to the acquired fluorescence intensities, and excellent linear correlations (R-2 > 0.9) were observed. In addition, the enumeration of the cells using hemocytometer to determine its performance accuracy was analyzed by Student's t-test, and no statistically significant difference was found. Therefore, different cell concentrations are reversely calculated, and the system can provide a rapid and cost-effective alternative to commercial hemocytometer for live cell or microparticle counting.
引用
收藏
页数:11
相关论文
共 20 条
[1]  
Absher M., 1973, Tissue Culture, P395, DOI [DOI 10.1016/B978-0-12-427150-0.50098-X, 10.1016/b978-0-12-427150-0.50098-x]
[2]   Flow cytometry: basic principles and applications [J].
Adan, Aysun ;
Alizada, Gunel ;
Kiraz, Yagmur ;
Baran, Yusuf ;
Nalbant, Ayten .
CRITICAL REVIEWS IN BIOTECHNOLOGY, 2017, 37 (02) :163-176
[3]   Poisson statistics-mediated particle/cell counting in microwell arrays [J].
Ahrberg, Christian D. ;
Lee, Jong Min ;
Chung, Bong Geun .
SCIENTIFIC REPORTS, 2018, 8
[4]   Muon tracking system with Silicon Photomultipliers [J].
Arneodo, F. ;
Benabderrahmane, M. L. ;
Dahal, S. ;
Di Giovanni, A. ;
Clemens, L. Pazos ;
Candela, A. ;
D'Incecco, M. ;
Sablone, D. ;
Franchi, G. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 799 :166-171
[5]  
Cassens U, 2004, ANTIVIR THER, V9, P395
[6]   Combinational light emitting diode-high frequency focused ultrasound treatment for HeLa cell [J].
Choe, Se-Woon ;
Park, Kitae ;
Park, Chulwoo ;
Ryu, Jaemyung ;
Choi, Hojong .
COMPUTER ASSISTED SURGERY, 2017, 22 :79-85
[7]   Standardization of microparticle enumeration across different flow cytometry platforms: results of a multicenter collaborative workshop [J].
Cointe, S. ;
Judicone, C. ;
Robert, S. ;
Mooberry, M. J. ;
Poncelet, P. ;
Wauben, M. ;
Nieuwland, R. ;
Key, N. S. ;
Dignat-George, F. ;
Lacroix, R. .
JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2017, 15 (01) :187-193
[8]   A facile and high sensitive micro fluorimeter based on light emitting diode and photodiode [J].
Geng, Xuhui ;
Gao, Yan ;
Feng, Chunbo ;
Guan, Yafeng .
TALANTA, 2017, 175 :183-188
[9]  
Kaushik S., MAGNETIC FLOW CYTOME
[10]   3D-printed smartphone-based point of care tool for fluorescence- and magnetophoresis-based cytometry [J].
Knowlton, Stephanie ;
Joshi, Ashwini ;
Syrrist, Philip ;
Coskun, Ahmet F. ;
Tasoglu, Savas .
LAB ON A CHIP, 2017, 17 (16) :2839-2851