Simultaneous voltammetric determination of 2-nitrophenol and 4-nitrophenol based on an acetylene black paste electrode modified with a graphene-chitosan composite

被引:58
作者
Deng, Peihong [1 ]
Xu, Zhifeng [1 ]
Li, Junhua [1 ]
机构
[1] Hengyang Normal Univ, Dept Chem & Mat Sci, Hengyang 421008, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
Graphene; Chitosan; Acetylene black; 2-nitrophenol; 4-nitrophenol; Simultaneous determination; GLASSY-CARBON ELECTRODE; NITROPHENOL ISOMERS; ELECTROCATALYTIC REDUCTION; MESOPOROUS SILICA; P-NITROPHENOL; FILM; ADSORPTION; BEHAVIOR; SENSOR;
D O I
10.1007/s00604-014-1206-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We describe a simple and sensitive voltammetric method for the simultaneous determination of 2-nitrophenol and 4-nitrophenol. It is based on the use of an acetylene black paste electrode modified with a graphene-chitosan composite film (denoted as Gr-Chit/ABPE). The reduction peak currents of 2-nitrophenol (at -252 mV) and of 4-nitrophenol (at -340 mV) in pH 1.0 solution increase significantly at the Gr-Chit/ABPE in comparison to a bare ABPE. Factors affecting sensitivity were optimized and a linear relationship is found between peak current and the concentrations of 2-nitrophenol (in the 0.4 mu M to 80 mu M range) and for 4-nitrophenol (in the 0.1 mu M to 80 mu M range). The detection limits (at an SNR of 3 and after a 30-s accumulation time) are 200 nM for 2-nitrophenol and 80 nM for 4-nitrophenol, respectively. The modified electrode was successfully applied to the direct and parallel determination of 2-nitrophenol and 4-nitrophenol in spiked water samples.
引用
收藏
页码:1077 / 1084
页数:8
相关论文
共 35 条
[1]   Electrochemical oxidation of p-nitrophenol using graphene-modified electrodes, and a comparison to the performance of MWNT-based electrodes [J].
Arvinte, Adina ;
Mahosenaho, Mika ;
Pinteala, Mariana ;
Sesay, Adama-Marie ;
Virtanen, Vesa .
MICROCHIMICA ACTA, 2011, 174 (3-4) :337-343
[2]  
Bard AJ, 1980, ELECTROCHEMICAL METH, P1980
[3]   Determination of toxic nitrophenols in the atmosphere by high-performance liquid chromatography [J].
Belloli, R ;
Barletta, B ;
Bolzacchini, E ;
Meinardi, S ;
Orlandi, M ;
Rindone, B .
JOURNAL OF CHROMATOGRAPHY A, 1999, 846 (1-2) :277-281
[4]   Electrochemical simultaneous determination of nitrophenol isomers at nano-gold modified glassy carbon electrode [J].
Chu, Lin ;
Han, Lu ;
Zhang, Xiaoli .
JOURNAL OF APPLIED ELECTROCHEMISTRY, 2011, 41 (06) :687-694
[5]   Acetylene black paste electrode modified with graphene as the voltammetric sensor for selective determination of tryptophan in the presence of high concentrations of tyrosine [J].
Deng, Peihong ;
Xu, Zhifeng ;
Feng, Yonglan .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2014, 35 :54-60
[6]   Electrochemically reduced graphene oxide modified acetylene black paste electrode for the sensitive determination of bisphenol A [J].
Deng, Peihong ;
Xu, Zhifeng ;
Kuang, Yunfei .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2013, 707 :7-14
[7]   Acetylene black paste electrode modified with a molecularly imprinted chitosan film for the detection of bisphenol A [J].
Deng, Peihong ;
Xu, Zhifeng ;
Li, Junhua ;
Kuang, Yunfei .
MICROCHIMICA ACTA, 2013, 180 (9-10) :861-869
[8]   Electrocatalytic reduction and determination of p-nitrophenol on acetylene black paste electrode coated with salicylaldehyde-modified chitosan [J].
Deng, Peihong ;
Xu, Zhifeng ;
Feng, Yonglan ;
Li, Junhua .
SENSORS AND ACTUATORS B-CHEMICAL, 2012, 168 :381-389
[9]   Trace determination of zirconium by adsorptive anodic stripping voltammetry of its complex with alizarin violet using a glassy carbon electrode modified with acetylene black-dihexadecyl hydrogen phosphate composite film [J].
Deng, Peihong ;
Feng, Yonglan ;
Fei, Junjie .
MICROCHIMICA ACTA, 2011, 175 (3-4) :233-240
[10]   Platinum-catalyzed enzyme electrodes immobilized on gold using self-assembled layers [J].
Gooding, JJ ;
Praig, VG ;
Hall, EAH .
ANALYTICAL CHEMISTRY, 1998, 70 (11) :2396-2402