Detection of serum hepcidin in renal failure and inflammation by using ProteinChip System
被引:238
作者:
Tomosugi, Naohisa
论文数: 0引用数: 0
h-index: 0
机构:
Kanazawa Med Univ, Div Nephrol, Dept Internal Med, Kahoku, Ishikawa 9200293, JapanKanazawa Med Univ, Div Nephrol, Dept Internal Med, Kahoku, Ishikawa 9200293, Japan
Tomosugi, Naohisa
[1
]
Kawabata, Hiroshi
论文数: 0引用数: 0
h-index: 0
机构:Kanazawa Med Univ, Div Nephrol, Dept Internal Med, Kahoku, Ishikawa 9200293, Japan
Kawabata, Hiroshi
Wakatabe, Rumi
论文数: 0引用数: 0
h-index: 0
机构:Kanazawa Med Univ, Div Nephrol, Dept Internal Med, Kahoku, Ishikawa 9200293, Japan
Wakatabe, Rumi
Higuchi, Masato
论文数: 0引用数: 0
h-index: 0
机构:Kanazawa Med Univ, Div Nephrol, Dept Internal Med, Kahoku, Ishikawa 9200293, Japan
Higuchi, Masato
Yamaya, Hideki
论文数: 0引用数: 0
h-index: 0
机构:Kanazawa Med Univ, Div Nephrol, Dept Internal Med, Kahoku, Ishikawa 9200293, Japan
Yamaya, Hideki
Umehara, Hisanori
论文数: 0引用数: 0
h-index: 0
机构:Kanazawa Med Univ, Div Nephrol, Dept Internal Med, Kahoku, Ishikawa 9200293, Japan
Umehara, Hisanori
Ishikawa, Isao
论文数: 0引用数: 0
h-index: 0
机构:Kanazawa Med Univ, Div Nephrol, Dept Internal Med, Kahoku, Ishikawa 9200293, Japan
Ishikawa, Isao
机构:
[1] Kanazawa Med Univ, Div Nephrol, Dept Internal Med, Kahoku, Ishikawa 9200293, Japan
[2] Kyoto Univ, Grad Sch Med, Dept Hematol & Oncol, Kyoto, Japan
[3] Biomarker Discovery Ctr, Ciphergen Biosyst, Yokohama, Kanagawa, Japan
Hepcidin, a key regulator of iron metabolism, is expressed in the liver, distributed in blood, and excreted in urine. However, to date, no reliable and practical method for measuring the bloactive form of hepcidin in serum has been developed. Here, we used surface-enhanced laser desorption ionization time of flight mass spectrometry (SELDI-TOF MS) to analyze the distinctive serum proteomic patterns of patients receiving hemodialysis. In the range of 1000 to 15 000 m/z, we found peptides at 2192, 2789, and 2851 m/z that showed a significant correlation with the serum ferritin levels. The molecular sizes of peptides at 2192 and 2789 m/z matched with the reported sizes of hepcidin-20 and -25, respectively, and the serum peptide at 2789 m/z was identified as hepcidin-25 by collision-induced dissociation tandem MS. By using SELDI-TOF MS, we developed a serniquantitative assay for hepcidin-25. In this assay, the level of serum hepcidin-25 correlated well with levels of serum ferritin and serum interleukin-6. Hepcidin-25 was found to accumulate in the serum of patients receiving hemodialysis; this could contribute to the pathogenesis of renal anemia by decreasing the available iron for hematopoiesis. Thus, SELDI-TOF MS would be a clinically useful tool to detect and semiquantify bioactive hepcidin in serum.