Modern magnetic resonance imaging of the liver

被引:0
作者
Hedderich, D. M. [1 ]
Weiss, K. [1 ,2 ]
Maintz, D. [1 ]
Persigehl, T. [1 ]
机构
[1] Univ Klinikum Koln, Inst Diagnost & Interventionelle Radiol, Kerpener Str 62, D-50937 Cologne, Germany
[2] Philips Healthcare Deutschland, Hamburg, Germany
来源
RADIOLOGE | 2015年 / 55卷 / 12期
关键词
Focal liver diseases; Diffuse liver diseases; Magnetic resonance imaging; Examination sequences; Protocol; WATER-FAT SEPARATION; UPPER ABDOMEN; MR CHOLANGIOPANCREATOGRAPHY; T2-WEIGHTED MRI; GADOXETIC ACID; TEST-INJECTION; SPIN-ECHO; IRON; ACQUISITION; MOTION;
D O I
10.1007/s00117-015-0031-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Magnetic resonance imaging (MRI) of the liver has become an essential tool in the radiological diagnostics of both focal and diffuse diseases of the liver and is subject to constant change due to technological progress. Recently, important improvements could be achieved by innovations regarding MR hardware, sequences and postprocessing methods. The diagnostic spectrum of MRI could be broadened particularly due to new examination sequences, while at the same time scanning time could be shortened and image quality has been improved. The aim of this article is to explain both the technological background and the clinical application of recent MR sequence developments and to present the scope of a modern MRI protocol for the liver.
引用
收藏
页码:1045 / 1056
页数:12
相关论文
共 60 条
[1]  
ACR, 2015, ACR SAR SPR PRACT PA
[2]  
ACR Committee on Drucs and Contrast Media, 2015, ACR MAN CONTR MED VE
[3]   Evaluation of Fibrotic Liver Disease with Whole-Liver T1ρ MR Imaging: A Feasibility Study at 1.5 T [J].
Allkemper, Thomas ;
Sagmeister, Florian ;
Cicinnati, Vito ;
Beckebaum, Susanne ;
Kooijman, Hendrik ;
Kanthak, Christian ;
Stehling, Christoph ;
Heindel, Walter .
RADIOLOGY, 2014, 271 (02) :408-415
[4]   Hepatic Iron Quantification on 3 Tesla (3 T) Magnetic Resonance (MR): Technical Challenges and Solutions [J].
Anwar, Muhammad ;
Wood, John ;
Manwani, Deepa ;
Taragin, Benjamin ;
Oyeku, Suzette O. ;
Peng, Qi .
RADIOLOGY RESEARCH AND PRACTICE, 2013, 2013
[5]   Focal liver lesions: MR imaging-pathologic correlation [J].
Bartolozzi, C ;
Cioni, D ;
Donati, F ;
Lencioni, R .
EUROPEAN RADIOLOGY, 2001, 11 (08) :1374-1388
[6]   T2-weighted MRI of the Upper Abdomen: Comparison of Four Fat-Suppressed T2-weighted Sequences Including PROPELLER (BLADE) Technique [J].
Bayramoglu, Sibel ;
Kilickesmez, Oezguer ;
Cimilli, Tan ;
Kayhan, Arda ;
Yirik, Guelseren ;
Islim, Filiz ;
Alibek, Sedat .
ACADEMIC RADIOLOGY, 2010, 17 (03) :368-374
[7]   Contrast-enhanced timing robust acquisition order with a preparation of the longitudinal signal component (CENTRA plus) for 3D contrast-enhanced abdominal imaging [J].
Beck, Gabriele M. ;
De Becker, Jan ;
Jones, Alun C. ;
von Falkenhausen, Marcus ;
Willinek, Winfried A. ;
Gieseke, Juergen .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (06) :1461-1467
[8]   Prevalence of hepatic steatosis in an urban population in the United States: Impact of ethnicity [J].
Browning, JD ;
Szczepaniak, LS ;
Dobbins, R ;
Nuremberg, P ;
Horton, JD ;
Cohen, JC ;
Grundy, SM ;
Hobbs, HH .
HEPATOLOGY, 2004, 40 (06) :1387-1395
[9]  
Cassinotto C, 2015, EUR J RADIOL, V40, P1387
[10]   The Effects of SENSE on PROPELLER Imaging [J].
Chang, Yuchou ;
Pipe, James G. ;
Karis, John P. ;
Gibbs, Wende N. ;
Zwart, Nicholas R. ;
Schaer, Michael .
MAGNETIC RESONANCE IN MEDICINE, 2015, 74 (06) :1598-1608