摘要
Electromyography (EMG) artifacts are the main and serious contaminated sources to the electroencephalogram (EEG) signals. In this paper, a fully automated EMG removal technique based on canonical correlation analysis (CCA) method is presented. CCA method was proved more suitable to reconstruct the EMG-free EEG data than independent component analysis (ICA) methods in the study. Specially, a number of contaminated and clean EEG data were analyzed in order to decide a reasonable correlation threshold, by which this method can remove successfully not only the light EMG artifacts but also heavy EMG artifacts from the EEG data in real-time application with the little distortion of not only the underlying ictal activity signal but the EOG artifacts.
引用
收藏
页码:28 / 31
页数:4
相关论文
共 50 条
  • [1] Comparison of Blind Source Separation Methods for Removal of Eye Blink Artifacts from EEG
    Soomro, Mumtaz Hussain
    Badruddin, Nasreen
    Yusoff, Mohd Zuki
    2014 5TH INTERNATIONAL CONFERENCE ON INTELLIGENT AND ADVANCED SYSTEMS (ICIAS 2014), 2014,
  • [2] Removal of Transcranial Alternating Current Stimulation EEG Artifacts Using Blind Source Separation and Wavelets
    Yan, Xuanteng
    Boudrias, Marie-Helene
    Mitsis, Georgios D.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2022, 69 (10) : 3183 - 3192
  • [3] Removal of EMG and ECG artifacts from EEG based on wavelet transform and ICA
    Zhou, WD
    Gotman, J
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 392 - 395
  • [4] Removing Noise and Artifacts from EEG Using Adaptive Noise Cancelator and Blind Source Separation
    Cuong, Nguyen T. K.
    Ha, Vo Q.
    Huong, Nguyen T. M.
    Truong Quang Dang Khoa
    Nguyen Huynh Minh Tam
    Linh, Huynh Q.
    Vo Van Toi
    THIRD INTERNATIONAL CONFERENCE ON THE DEVELOPMENT OF BIOMEDICAL ENGINEERING IN VIETNAM, 2010, 27 : 282 - +
  • [5] Removal OF EMG and ECG artifacts from EEG based on real time recurrent learning algorithm
    Suresh, H. N.
    Puttamadappa, C.
    INTERNATIONAL JOURNAL OF THE PHYSICAL SCIENCES, 2008, 3 (05): : 120 - 125
  • [6] Removal of EEG noise and artifact using blind source separation
    Fitzgibbon, S. P.
    Powers, D. M. W.
    Pope, K. J.
    Clark, C. R.
    JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 2007, 24 (03) : 232 - 243
  • [7] Muscle Artifact Removal in Ictal Scalp-EEG Based on Blind Source Separation
    Karfoul, Ahmad
    Kachenoura, Amar
    Albera, Laurent
    Safieddine, Doha
    Pasnicu, Anca
    Wendling, Fabrice
    Senhadji, Lotfi
    Merlet, Isabelle
    6TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, 2015, 45 : 485 - +
  • [8] Automatic removal of eye movement and blink artifacts from EEG data using blind component separation
    Joyce, CA
    Gorodnitsky, IF
    Kutas, M
    PSYCHOPHYSIOLOGY, 2004, 41 (02) : 313 - 325
  • [9] Removal of Artifacts in Electroencephalogram Using Adaptive Infomax Algorithm of Blind Source Separation
    Guo, Wanyou
    Huang, Liyu
    Gao, Li
    Zhu, Tianqiao
    Huang, Yuangui
    ADVANCED INTELLIGENT COMPUTING THEORIES AND APPLICATIONS, PROCEEDINGS: WITH ASPECTS OF ARTIFICIAL INTELLIGENCE, 2008, 5227 : 717 - +
  • [10] Artifacts-matched blind source separation and wavelet transform for multichannel EEG denoising
    Mowla, Md Rakibul
    Ng, Siew-Cheok
    Zilany, Muhammad S. A.
    Paramesran, Raveendran
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2015, 22 : 111 - 118