Numerical analysis of a modified type pulse tube refrigerator

被引:3
|
作者
Rout, Sachindra Kumar [1 ]
Behura, Arun Kumar [2 ]
Dalai, Sisir [3 ]
Sahoo, Ranjit Kumar [3 ]
机构
[1] CV Raman Coll Engn, Dept Mech Engn, Bhubaneswar 752054, Orissa, India
[2] Poornima Coll Engn, Dept Mech Engn, Jaipur, Rajasthan, India
[3] Natl Inst Technol, Rourkela, Odisha, India
来源
INTERNATIONAL CONFERENCE ON RECENT ADVANCEMENT IN AIR CONDITIONING AND REFRIGERATION, RAAR 2016 | 2017年 / 109卷
关键词
MPTR; pulse tube; DC gas flow; orifice; DOUBLE-INLET; CRYOCOOLER; 4-VALVE;
D O I
10.1016/j.egypro.2017.03.067
中图分类号
O414.1 [热力学];
学科分类号
摘要
The loss generated due to direct current gas flow in pulse tube refrigerator (PTR) is one of the major problems which significantly affect the cooling performance. It generates temperature fluctuation at the cold end of the PTR. A new type PTR has been proposed in the present work to diminish the DC flow problem by attaching an additional connection at the hot end from a secondary compressor and investigated numerically using CFD simulation software FLUENT. It is reported a significant enhancement of cooling performance by means of the proposed model. The numerical outcomes of the proposed model are equated with the outcomes of the orifice type pulse tube refrigerator (OPTR) model. The model used for analysis is an axisymmetric model. At 34 Hz operating frequency and 1.2 pressure ratio the numerical simulation is conducted. The proposed model achieves a temperature of 98 K at cold end where as a simple OPTR having same dimension riches a temperature of 130 K. To get an optimum result experimentally for the pulse tube refrigerator, is a very difficult and also high expensive hence the numerical approach is an alternate solution. (C) 2017 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:456 / 462
页数:7
相关论文
共 50 条
  • [31] Experimental study on the design of orifice pulse tube refrigerator
    Huang, BJ
    Yu, GJ
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2001, 24 (05): : 400 - 408
  • [32] Regenerative effect of heat exchanger in pulse tube refrigerator
    Guo, Zhimin
    Zhu, Shaowei
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2020, 118 : 114 - 120
  • [33] Computational fluid dynamics simulations of an orifice type pulse tube refrigerator: Effects of operating frequency
    Antao, Dion Savio
    Farouk, Bakhtier
    CRYOGENICS, 2011, 51 (04) : 192 - 201
  • [34] Step-by-step design methodology for efficient Stirling-type pulse tube refrigerator
    Ki, Taekyung
    Jeong, Sangkwon
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2012, 35 (04): : 1166 - 1175
  • [35] A high efficiency stirling-type pulse tube refrigerator for cooling above 200 K
    Wang, Bo
    Chao, Yijun
    Zhao, Qinyu
    Wang, Haoren
    Wang, Yabin
    Gan, Zhihua
    ENERGY, 2021, 215
  • [36] Optimization of a two stage pulse tube refrigerator for the integrated current lead system
    Maekawa, R.
    Matsubara, Y.
    Okada, A.
    Takami, S.
    Konno, M.
    Tomioka, A.
    Imayoshi, T.
    Hayashi, H.
    Mito, T.
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS 53A AND 53B, 2008, 985 : 101 - +
  • [37] Visualization of oscillating flow in a double-inlet pulse tube refrigerator with a diaphragm inserted in a bypass-tube
    Shiraishi, Masao
    Murakami, Masahide
    CRYOGENICS, 2012, 52 (7-9) : 410 - 415
  • [38] A small helium-3 pulse-tube refrigerator
    Tanaeva, IA
    de Waele, ATAM
    CRYOGENICS, 2005, 45 (08) : 578 - 584
  • [39] Tandem GM type-pulse tube refrigerator with novel rotary valve and bypass valve mechanism
    Jung, J.
    Jeono, S.
    Kwon, Y.
    Sohn, M.
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS 51A AND B, 2006, 823 : 853 - +
  • [40] 13 K thermally coupled two-stage Stirling-type pulse tube refrigerator
    THUMMES Günter
    ChineseScienceBulletin, 2005, (16) : 144 - 146