Contemporary procedural trends of Watchman percutaneous left atrial appendage occlusion in the United States

被引:29
作者
Munir, Muhammad Bilal [1 ]
Khan, Muhammad Zia [2 ]
Darden, Douglas [1 ]
Pasupula, Deepak K. [3 ]
Balla, Sudarshan [2 ]
Han, Frederick T. [1 ]
Reeves, Ryan [1 ]
Hsu, Jonathan C. [1 ]
机构
[1] Univ Calif San Diego, Div Cardiol, Sect Electrophysiol, 9452 Med Ctr Dr,MC7411, La Jolla, CA 92037 USA
[2] West Virginia Univ, Div Cardiovasc Med, Heart & Vasc Inst, Morgantown, WV 26506 USA
[3] Univ Pittsburgh, Med Ctr, Div Cardiol, Heart & Vasc Inst, Pittsburgh, PA USA
关键词
complications; mortality; national trends; Watchman; STROKE PREVENTION; 5-YEAR OUTCOMES; FIBRILLATION; CLOSURE; THERAPY; DEVICE; SAFETY;
D O I
10.1111/jce.14804
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective To determine trends in real-world utilization and in-hospital adverse events from Watchman implantation since its approval by the Food and Drug Administration in 2015. Background The risk of embolic stroke caused by atrial fibrillation is reduced by oral anticoagulants, but not all patients can tolerate long-term anticoagulation. Left atrial appendage occlusion with the Watchman device has emerged as an alternative therapy. Methods This was a retrospective cohort study utilizing data from National Inpatient Sample for calendar years 2015-2017. The outcomes assessed in this study were associated complications, in-hospital mortality, and resource utilization trends after Watchman implantation. Trends analysis were performed using analysis of variance. Multivariable adjusted logistic regression analysis was performed to determine predictors of mortality. Results A total of 17 700 patients underwent Watchman implantation during the study period. There was a significantly increased trend in the number of Watchman procedures performed over the study years (from 1195 in 2015 to 11 165 devices in 2017, p < .01). A significant decline in the rate of complications (from 26.4% in 2015% to 7.9% in 2017, p < .01) and inpatient mortality (from 1.3% in 2015% to 0.1% in 2017, p < .01) were noted. Predictors of in-hospital mortality included a higher CHA(2)DS(2)-VASc score (odds ratio [OR]: 2.61 per 1-point increase, 95% confidence interval [CI]: 1.91-3.57), chronic blood loss anemia (OR: 3.63, 95% CI: 1.37-9.61) and coagulopathy (OR: 4.90, 95% CI: 2.32-10.35). Conclusion In contemporary United States clinical practice, Watchman utilization has increased significantly since approval in 2015, while complications and in-patient mortality have declined.
引用
收藏
页码:83 / 92
页数:10
相关论文
共 19 条
[1]  
Agency for Healthcare Research and Quality, 2020, OV NAT INP SAMPL NIS
[2]   Stroke Prevention in Nonvalvular Atrial Fibrillation A Stakeholder Perspective [J].
Alkhouli, Mohamad ;
Noseworthy, Peter A. ;
Rihal, Charanjit S. ;
Holmes, David R., Jr. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (24) :2790-2801
[3]   Implant success and safety of left atrial appendage closure with the WATCHMAN device: peri-procedural outcomes from the EWOLUTION registry [J].
Boersma, Lucas V. A. ;
Schmidt, Boris ;
Betts, Timothy R. ;
Sievert, Horst ;
Tamburino, Corrado ;
Teiger, Emmanuel ;
Pokushalov, Evgeny ;
Kische, Stephan ;
Schmitz, Thomas ;
Stein, Kenneth M. ;
Bergmann, MartinW. .
EUROPEAN HEART JOURNAL, 2016, 37 (31) :2465-2474
[4]   Worldwide Epidemiology of Atrial Fibrillation A Global Burden of Disease 2010 Study [J].
Chugh, Sumeet S. ;
Havmoeller, Rasmus ;
Narayanan, Kumar ;
Singh, David ;
Rienstra, Michiel ;
Benjamin, Emelia J. ;
Gillum, Richard F. ;
Kim, Young-Hoon ;
McAnulty, John H. ;
Zheng, Zhi-Jie ;
Forouzanfar, Mohammad H. ;
Naghavi, Mohsen ;
Mensah, George A. ;
Ezzati, Majid ;
Murray, Christopher J. L. .
CIRCULATION, 2014, 129 (08) :837-847
[5]   The NCDR Left Atrial Appendage Occlusion Registry [J].
Freeman, James, V ;
Varosy, Paul ;
Price, Matthew J. ;
Slotwiner, David ;
Kusumoto, Fred M. ;
Rammohan, Chidambaram ;
Kavinsky, Clifford J. ;
Turi, Zoltan G. ;
Akar, Joseph ;
Koutras, Cristina ;
Curtis, Jeptha P. ;
Masoudi, Frederick A. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 75 (13) :1503-1518
[6]   Rates and Determinants of 5-Year Outcomes After Atrial Fibrillation-Related Stroke A Population Study [J].
Hayden, Derek T. ;
Hannon, Niamh ;
Callaly, Elizabeth ;
Chroinin, Danielle Ni ;
Horgan, Gillian ;
Kyne, Lorraine ;
Duggan, Joseph ;
Dolan, Eamon ;
O'Rourke, Killian ;
Williams, David ;
Murphy, Sean ;
Kelly, Peter J. .
STROKE, 2015, 46 (12) :3488-3493
[7]   Percutaneous closure of the left atrial appendage versus warfarin therapy for prevention of stroke in patients with atrial fibrillation: a randomised non-inferiority trial [J].
Holmes, David R. ;
Reddy, Vivek Y. ;
Turi, Zoltan G. ;
Doshi, Shephal K. ;
Sievert, Horst ;
Buchbinder, Maurice ;
Mullin, Christopher M. ;
Sick, Peter .
LANCET, 2009, 374 (9689) :534-542
[8]   Long-Term Safety and Efficacy in Continued Access Left Atrial Appendage Closure Registries [J].
Holmes, David R., Jr. ;
Reddy, Vivek Y. ;
Gordon, Nicole T. ;
Delurgio, David ;
Doshi, Shephal K. ;
Desai, Amish J. ;
Stone, James E., Jr. ;
Kar, Saibal .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 74 (23) :2878-2889
[9]   Left Atrial Appendage Occlusion for The Unmet Clinical Needs of Stroke Prevention in Nonvalvular Atrial Fibrillation [J].
Holmes, David R., Jr. ;
Alkhouli, Mohamad ;
Reddy, Vivek .
MAYO CLINIC PROCEEDINGS, 2019, 94 (05) :864-874
[10]   Prospective Randomized Evaluation of the Watchman Left Atrial Appendage Closure Device in Patients With Atrial Fibrillation Versus Long-Term Warfarin Therapy [J].
Holmes, David R., Jr. ;
Kar, Saibal ;
Price, Matthew J. ;
Whisenant, Brian ;
Sievert, Horst ;
Doshi, Shephal K. ;
Huber, Kenneth ;
Reddy, Vivek Y. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (01) :1-12