Integrated theoretical model for performance evaluation of flat-sheet membrane-based absorptive dehumidification module using lithium chloride-water solution

被引:5
作者
Jeon, Woo-Jin [1 ]
Kim, Woo-Seung [2 ]
Kim, Young-Deuk [2 ]
机构
[1] Hanyang Univ, Dept Mech Design Engn, 222 Wangsimni Ro, Seoul 04763, South Korea
[2] Hanyang Univ, Dept Mech Engn, Hanyangdaehak Ro 55, Ansan 15588, Gyeonggi Do, South Korea
基金
新加坡国家研究基金会;
关键词
Dehumidification; Membrane; Liquid desiccant; Flow configuration; Channel height; LIQUID DESICCANT DEHUMIDIFICATION; ENERGY EXCHANGER LAMEE; MASS-TRANSFER; AIR DEHUMIDIFICATION; FLOW; HEAT; SYSTEM; CONTACTOR; RAMEE;
D O I
10.1016/j.seppur.2019.115794
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
This paper presents an integrated theoretical model to evaluate the performance of a flat-sheet membrane-based absorptive dehumidification module with different flow arrangements (i.e., cocurrent, countercurrent, and cross flow configurations) using an aqueous lithium chloride desiccant. The model results showed good consistency with experimental data, with a maximum relative error of approximately 7%. The performance of the flat-sheet dehumidification module was evaluated for various air and solution channel heights ranging from 1 to 5 mm at a constant Reynolds number in both channels, in terms of sensible, latent, and total effectivenesses. The sensible effectiveness increased with a decrease in the air channel height and an increase in the solution channel height; in particular, the effect of the solution channel height was more pronounced in the cocurrent flow configuration. In addition, the latent effectiveness increased with a decrease in both channel heights. Thus, there was a trade-off between the effects of the solution channel height on the sensible and latent effectivenesses; consequently, the effect of the solution channel height on the total effectiveness was mitigated. The total effectiveness was observed to decrease in the order of countercurrent, cross-, and cocurrent flow configurations; here, its value in the countercurrent flow configuration was approximately 0.788 when both channel heights were 1 mm.
引用
收藏
页数:14
相关论文
共 28 条
  • [1] Design and testing of a novel 3-fluid liquid-to-air membrane energy exchanger (3-fluid LAMEE)
    Abdel-Salam, Mohamed R. H.
    Besant, Robert W.
    Simonson, Carey J.
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2016, 92 : 312 - 329
  • [2] Parametric analysis of a cross-flow membrane-based parallel-plate liquid desiccant dehumidification system: Numerical and experimental data
    Bai, Hongyu
    Zhu, Jie
    Chen, Ziwei
    Chu, Junze
    [J]. ENERGY AND BUILDINGS, 2018, 158 : 494 - 508
  • [3] On the performances of a hybrid air-conditioning system in different climatic conditions
    Bergero, Stefano
    Chiari, Anna
    [J]. ENERGY, 2011, 36 (08) : 5261 - 5273
  • [4] Experimental performance of indirect air-liquid membrane contactors for liquid desiccant cooling systems
    Das, Rajat Subhra
    Jain, Sanjeev
    [J]. ENERGY, 2013, 57 : 319 - 325
  • [5] Dieckmann J, 2011, ASHRAE J, V53, P90
  • [6] Erb B, 2009, ASHRAE TRAN, V115, P689
  • [7] Temperature polarization in pervaporation
    Favre, E
    [J]. DESALINATION, 2003, 154 (02) : 129 - 138
  • [8] Comparison of experimental data and a model for heat and mass transfer performance of a liquid-to-air membrane energy exchanger (LAMEE) when used for air dehumidification and salt solution regeneration
    Ge, Gaoming
    Moghaddam, Davood Ghadiri
    Abdel-Salam, Ahmed H.
    Besant, Robert W.
    Simonson, Carey J.
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2014, 68 : 119 - 131
  • [9] Analytical model based performance evaluation, sizing and coupling flow optimization of liquid desiccant run-around membrane energy exchanger systems
    Ge, Gaoming
    Moghaddam, Davood Ghadiri
    Namvar, Ramin
    Simonson, Carey J.
    Besant, Robert W.
    [J]. ENERGY AND BUILDINGS, 2013, 62 : 248 - 257
  • [10] Godish Thad., 2001, Indoor Environmental Quality