Measurement of inspiratory flow in children with acute asthma

被引:13
作者
Bentur, L
Mansour, Y
Hamzani, Y
Beck, R
Elias, N
Amirav, I
机构
[1] Meyer Childrens Hosp, Pediat Pulm Unit, Rambam Med Ctr, IL-31092 Haifa, Israel
[2] Technion Israel Inst Technol, Fac Med, Haifa, Israel
[3] Sieff Hosp, Dept Pediat, Safed, Israel
关键词
dry-powder inhalers; asthmatic attack; children; peak inspiratory flow;
D O I
10.1002/ppul.20109
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Dry-powder inhalers (DPIs) have been proposed for treatment of acute asthma. Different DPIs vary in their inspiratory resistance and have different recommended optimal peak inspiratory flows (PIFs). Reduced PIF during acute asthma may result in inadequate drug delivery to the lungs. Our aim was to measure the inspiratory flow in relation to inspiratory resistance during acute asthma in children presenting to the emergency room. School-age (range, 6-18 years) children were referred to the emergency room for acute asthma. PIF measurements were performed by In-Check DiaI(TM) device with simulated airflow resistances equivalent to Turbuhaler((R)), Diskus,((R)) and free flow. Percent change in PIF between remission and acute asthma (%Delta) was correlated with percent change in clinical score (CS) and percent change in spirometry in children <9 and >9 years old. Thirty-three children (21 males) participated. PIF with simulated Turbuhaler resistance was significantly lower than with simulated Diskus resistance in both acute and remission states (P<0.0001). PIF with simulated Turbuhaler resistance increased from 62.1 +/- 15.3 (acute) to 74.4 +/- 16.5 l/min (remission, P<0.0001), while with Diskus it rose from 72.6 +/- 20.5 to 91.1 +/- 18.9 l/min (P<0.0001). Turbuhaler %Delta PIF correlated with %Delta FEV1 (P=0.01) and with %Delta CS (P=0.0001). A lesser degree of correlation was observed while using Diskus resistance and in children above 9 years old. During acute asthmatic attacks, PIF is reduced; this reduction is particularly prominent in young children who use a high-resistance device. However, the PIF generated is generally within the values considered compatible with adequate lung deposition with both Diskus and Turbuhaler. (C) 2004 Wiley-Liss, Inc.
引用
收藏
页码:304 / 307
页数:4
相关论文
共 18 条
[1]  
BISGAARD H, 1996, AM J RESP CRIT CARE, V153, P75
[2]   LUNG DEPOSITION OF BUDESONIDE INHALED VIA TURBUHALER(R) - A COMPARISON WITH TERBUTALINE SULFATE IN NORMAL SUBJECTS [J].
BORGSTROM, L ;
BONDESSON, E ;
MOREN, F ;
TROFAST, E ;
NEWMAN, SP .
EUROPEAN RESPIRATORY JOURNAL, 1994, 7 (01) :69-73
[3]   PEAK INSPIRATORY FLOW-THROUGH TURBUHALER(R) IN ACUTE ASTHMA [J].
BROWN, PH ;
NING, ACWS ;
GREENING, AP ;
MCLEAN, A ;
CROMPTON, GK .
EUROPEAN RESPIRATORY JOURNAL, 1995, 8 (11) :1940-1941
[4]   A novel hypothesis to explain the bronchconstrictor effect of deep inspiration in asthma [J].
Burns, GP ;
Gibson, GJ .
THORAX, 2002, 57 (02) :116-119
[5]  
Cohen J., 1988, STAT POWER ANAL BEHA
[6]   A comparison of the performance of two modern multidose dry powder asthma inhalers [J].
Hill, LS ;
Slater, AL .
RESPIRATORY MEDICINE, 1998, 92 (01) :105-110
[7]   Variation of peak inspiratory flow through dry powder inhalers in children with stable and unstable asthma [J].
Kamps, AWA ;
Brand, PLP ;
Roorda, RJ .
PEDIATRIC PULMONOLOGY, 2004, 37 (01) :65-70
[8]  
MALTON A, 1995, EUR J CLIN RES, V7, P177
[9]   A randomized controlled trial of inhaled flunisolide in the management of acute asthma in children [J].
Nakanishi, AK ;
Klasner, AK ;
Rubin, BK .
CHEST, 2003, 124 (03) :790-794
[10]   TERBUTALINE SULFATE TURBUHALER - EFFECT OF INHALED FLOW-RATE ON DRUG DEPOSITION AND EFFICACY [J].
NEWMAN, SP ;
MOREN, F ;
TROFAST, E ;
TALAEE, N ;
CLARKE, SW .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1991, 74 (2-3) :209-213