In-vitro/in-vivo comparison of inhaled salbutamol dose delivered by jet nebulizer, vibrating mesh nebulizer and metered dose inhaler with spacer during non-invasive ventilation

被引:33
|
作者
Hassan, Ahmed [1 ]
Eldin, Randa Salah [2 ]
Abdelrahman, Maha M. [3 ]
Abdelrahim, Mohamed E. [4 ,5 ]
机构
[1] Beba Gen Hosp, Hosp Pharm Dept, Bani Suwayf, Egypt
[2] Beni Suef Univ, Resp Dept, Fac Med, Bani Suwayf, Egypt
[3] Beni Suef Univ, Fac Pharm, Analyt Chem Dept, Bani Suwayf, Egypt
[4] Beni Suef Univ, Fac Pharm, Clin Pharm Dept, Bani Suwayf, Egypt
[5] Ahram Canadian Univ, Fac Pharm, Clin Pharm Dept, Giza, Egypt
关键词
nebulizer; non-invasive ventilation; salbutamol; spacer; urinary comparison; POSITIVE-PRESSURE VENTILATION; LUNG FOLLOWING INHALATION; NEXT-GENERATION IMPACTOR; AEROSOL DELIVERY; MECHANICAL VENTILATION; AERODYNAMIC CHARACTERISTICS; RELATIVE BIOAVAILABILITY; BRONCHODILATOR DELIVERY; ALBUTEROL DELIVERY; DRUG-DELIVERY;
D O I
10.1080/01902148.2017.1282993
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background: Patients receiving noninvasive ventilation (NIV) may benefit from medical aerosol, but most guidance on dosing with different aerosol devices is limited to in-vitro studies. The study was designed to in-vitro, ex-vivo, and in-vivo compare aerosol delivery during bilevel NIV with three types of aerosol generators: metered dose inhaler with AeroChamber-MV spacer (AC), Aerogen Pro vibrating mesh nebulizer (PRO), and Sidestream jet nebulizer (SIDE). Materials and Method: A bilevel ventilator with dry single limb circuit and fixed expiratory port was set in spontaneous mode with initial inspiratory and expiratory pressures of 20 and 5cmH(2)0, 1:3 inspiratory-expiratory ratio, and 15 breaths.min(-1). Aerosol generators were placed proximal to facial mask of NIV chronic obstructive pulmonary disease (COPD) patients. 1 mL salbutamol nebulizer solution (5 mg/mL) was nebulized using PRO and SIDE. 12MDI doses, containing 100g salbutamol each, were delivered using AC. In-vitro aerosol fate and aerodynamic droplet characteristics, in-vivo amount of salbutamol excreted 30mins and pooled up to 24h post inhalation in urine from 12 COPD patients (as indices of pulmonary deposition and systemic absorption, respectively) and amount of salbutamol deposited on ex-vivo filters (expected inhalable amount) was determined. Results: The in-vitro, in-vivo and ex-vivo testing showed that PRO had better aerosol delivery compared to SIDE (p < 0.01). However, with smaller nominal dose MDI with AC resulted in similar aerosol delivery to PRO suggesting better aerosol delivery stress on careful attention and proper delivery by health care provider. Conclusions: These similarities and differences between the three aerosol generators tested suggest that aerosol delivery methods should be carefully chosen or substituted in non-invasive ventilated patients.
引用
收藏
页码:19 / 28
页数:10
相关论文
共 32 条
  • [21] In-vitro characterisation of the nebulised dose during non-invasive ventilation
    Abdelrahim, Mohamed E.
    Plant, Paul
    Chrystyn, Henry
    JOURNAL OF PHARMACY AND PHARMACOLOGY, 2010, 62 (08) : 966 - 972
  • [22] Comparison Of Aerosol Delivery During Simulated Adult Noninvasive Positive Pressure Ventilation: Nebulizer Versus Pressurized Metered-Dose Inhaler
    Dhand, R.
    Wang, H.
    McCormack, M. T.
    Elder, C. S.
    Church, D.
    Turner, J. F.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2016, 193
  • [23] A mesh nebulizer is more effective than jet nebulizer to nebulize bronchodilators during non-invasive ventilation of subjects with COPD: A randomized controlled trial with radiolabeled aerosols
    Galindo-Filho, Valdecir Castor
    Alcoforado, Luciana
    Rattes, Catarina
    Paiva, Dulciane Nunes
    Soares Brandao, Simone Cristina
    Fink, James B.
    de Andrade, Armele Dornelas
    RESPIRATORY MEDICINE, 2019, 153 : 60 - 67
  • [24] Modelling of in-vitro and in-vivo performance of aerosol emitted from different vibrating mesh nebulisers in non-invasive ventilation circuit
    Rabea, Hoda
    Ali, Ahmed M. A.
    Eldin, Randa Salah
    Abdelrahman, Maha M.
    Said, Amira S. A.
    Abdelrahim, Mohamed E.
    EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2017, 97 : 182 - 191
  • [25] In Vitro Performance of an Investigational Vibrating-Membrane Nebulizer with Surfactant under Simulated, Non-Invasive Neonatal Ventilation Conditions: Influence of Continuous Positive Airway Pressure Interface and Nebulizer Positioning on the Lung Dose
    Bianco, Federico
    Pasini, Elena
    Nutini, Marcello
    Murgia, Xabier
    Stoeckl, Carolin
    Schlun, Martin
    Hetzer, Uwe
    Bonelli, Sauro
    Lombardini, Marta
    Milesi, Ilaria
    Pertile, Marisa
    Minocchieri, Stefan
    Salomone, Fabrizio
    Bucholski, Albert
    PHARMACEUTICS, 2020, 12 (03)
  • [26] EFFECT OF NEBULIZER DESIGN ON AEROSOL DELIVERY DURING NON-INVASIVE MECHANICAL VENTILATION: MODELING STUDY OF IN-VITRO DATA
    Saeed, Haitham
    Elberry, Ahmed A.
    Eldin, Abeer Salah
    Rabea, Hoda
    Abdelrahim, Mohamed
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2017, 30 (03) : 7 - 7
  • [27] Effects of ventilator settings, nebulizer and exhalation port position on albuterol delivery during non-invasive ventilation: an in-vitro study
    Yuda Sutherasan
    Lorenzo Ball
    Pasquale Raimondo
    Valentina Caratto
    Elisa Sanguineti
    Federico Costantino
    Maurizio Ferretti
    Robert M. Kacmarek
    Paolo Pelosi
    BMC Pulmonary Medicine, 17
  • [28] Effects of ventilator settings, nebulizer and exhalation port position on albuterol delivery during non-invasive ventilation: an in-vitro study
    Sutherasan, Yuda
    Ball, Lorenzo
    Raimondo, Pasquale
    Caratto, Valentina
    Sanguineti, Elisa
    Costantino, Federico
    Ferretti, Maurizio
    Kacmarek, Robert M.
    Pelosi, Paolo
    BMC PULMONARY MEDICINE, 2017, 17
  • [29] Comparison of salbutamol efficacy in children- via the metered-dose inhaler (MDI) with Volumatic® spacer and via the dry powder inhaler, Easyhaler®, with the nebulizer - in mild to moderate asthma exacerbation: a multicenter, randomized study
    Direkwatanachai, Chalerat
    Teeratakulpisarn, Jamaree
    Suntornlohanakul, Somchai
    Trakultivakorn, Muthita
    Ngamphaiboon, Jarungchit
    Wongpitoon, Nares
    Vangveeravong, Mukda
    ASIAN PACIFIC JOURNAL OF ALLERGY AND IMMUNOLOGY, 2011, 29 (01): : 25 - 33
  • [30] In vitro comparison of beclomethasone and salbutamol metered-dose inhaler aerosols inhaled during pediatric tidal breathing from four valved holding chambers
    Finlay, WH
    Zuberbuhler, P
    CHEST, 1998, 114 (06) : 1676 - 1680