In-vitro/in-vivo comparison of inhaled salbutamol dose delivered by jet nebulizer, vibrating mesh nebulizer and metered dose inhaler with spacer during non-invasive ventilation

被引:33
|
作者
Hassan, Ahmed [1 ]
Eldin, Randa Salah [2 ]
Abdelrahman, Maha M. [3 ]
Abdelrahim, Mohamed E. [4 ,5 ]
机构
[1] Beba Gen Hosp, Hosp Pharm Dept, Bani Suwayf, Egypt
[2] Beni Suef Univ, Resp Dept, Fac Med, Bani Suwayf, Egypt
[3] Beni Suef Univ, Fac Pharm, Analyt Chem Dept, Bani Suwayf, Egypt
[4] Beni Suef Univ, Fac Pharm, Clin Pharm Dept, Bani Suwayf, Egypt
[5] Ahram Canadian Univ, Fac Pharm, Clin Pharm Dept, Giza, Egypt
关键词
nebulizer; non-invasive ventilation; salbutamol; spacer; urinary comparison; POSITIVE-PRESSURE VENTILATION; LUNG FOLLOWING INHALATION; NEXT-GENERATION IMPACTOR; AEROSOL DELIVERY; MECHANICAL VENTILATION; AERODYNAMIC CHARACTERISTICS; RELATIVE BIOAVAILABILITY; BRONCHODILATOR DELIVERY; ALBUTEROL DELIVERY; DRUG-DELIVERY;
D O I
10.1080/01902148.2017.1282993
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background: Patients receiving noninvasive ventilation (NIV) may benefit from medical aerosol, but most guidance on dosing with different aerosol devices is limited to in-vitro studies. The study was designed to in-vitro, ex-vivo, and in-vivo compare aerosol delivery during bilevel NIV with three types of aerosol generators: metered dose inhaler with AeroChamber-MV spacer (AC), Aerogen Pro vibrating mesh nebulizer (PRO), and Sidestream jet nebulizer (SIDE). Materials and Method: A bilevel ventilator with dry single limb circuit and fixed expiratory port was set in spontaneous mode with initial inspiratory and expiratory pressures of 20 and 5cmH(2)0, 1:3 inspiratory-expiratory ratio, and 15 breaths.min(-1). Aerosol generators were placed proximal to facial mask of NIV chronic obstructive pulmonary disease (COPD) patients. 1 mL salbutamol nebulizer solution (5 mg/mL) was nebulized using PRO and SIDE. 12MDI doses, containing 100g salbutamol each, were delivered using AC. In-vitro aerosol fate and aerodynamic droplet characteristics, in-vivo amount of salbutamol excreted 30mins and pooled up to 24h post inhalation in urine from 12 COPD patients (as indices of pulmonary deposition and systemic absorption, respectively) and amount of salbutamol deposited on ex-vivo filters (expected inhalable amount) was determined. Results: The in-vitro, in-vivo and ex-vivo testing showed that PRO had better aerosol delivery compared to SIDE (p < 0.01). However, with smaller nominal dose MDI with AC resulted in similar aerosol delivery to PRO suggesting better aerosol delivery stress on careful attention and proper delivery by health care provider. Conclusions: These similarities and differences between the three aerosol generators tested suggest that aerosol delivery methods should be carefully chosen or substituted in non-invasive ventilated patients.
引用
收藏
页码:19 / 28
页数:10
相关论文
共 32 条
  • [1] IN-VITRO / IN-VIVO COMPARISON OF INHALED SALBUTAMOL DOSE DELIVERED BY JET NEBULIZER, VIBRATING MESH NEBULIZER AND METERED DOSE INHALER WITH SPACER IN NON-INVASIVE VENTILATION
    Hassan, Ahmed
    Eldin, Randa Salah
    Abdelrahman, Maha M.
    Abdelrahim, Mohamed
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2017, 30 (03) : 2 - 2
  • [2] Inhaled salbutamol dose delivered by jet nebulizer, vibrating mesh nebulizer and metered dose inhaler with spacer during invasive mechanical ventilation
    ElHansy, Muhammad H. E.
    Boules, Marina E.
    El Essawy, Assem Fouad Mohamed
    Al-Kholy, Mohamed Bakry
    Abdelrahman, Maha M.
    Said, Amira S. A.
    Hussein, Raghda R. S.
    Abdelrahim, Mohamed E.
    PULMONARY PHARMACOLOGY & THERAPEUTICS, 2017, 45 : 159 - 163
  • [3] COMPARISON OF SALBUTAMOL DELIVERED BY NEBULIZER OR METERED-DOSE INHALER WITH A PEAR-SHAPED SPACER IN ACUTE ASTHMA
    RODRIGO, G
    RODRIGO, C
    CURRENT THERAPEUTIC RESEARCH-CLINICAL AND EXPERIMENTAL, 1993, 54 (06): : 797 - 808
  • [4] Pulmonary deposition of salbutamol aerosol delivered by metered dose inhaler, jet nebulizer, and ultrasonic nebulizer in mechanically ventilated rabbits
    Fok, TF
    AlEssa, M
    Monkman, S
    Dolovich, M
    Girard, L
    Coates, G
    Kirpalani, H
    PEDIATRIC RESEARCH, 1997, 42 (05) : 721 - 727
  • [5] Pulmonary Deposition of Salbutamol Aerosol Delivered by Metered Dose Inhaler, Jet Nebulizer, and Ultrasonic Nebulizer in Mechanically Ventilated Rabbits
    Tai-Fai Fok
    Mazen Al-Essa
    Shelley Monkman
    Myrna Dolovich
    Lisa Girard
    Geoffrey Coates
    Haresh Kirpalani
    Pediatric Research, 1997, 42 : 721 - 727
  • [6] Treatment of acute severe asthma with inhaled albuterol delivered via jet nebulizer, metered dose inhaler with spacer, or dry powder
    Raimondi, AC
    Schottlender, J
    Lombardi, D
    Molfino, NA
    CHEST, 1997, 112 (01) : 24 - 28
  • [7] Use of a Metered-Dose Inhaler Compared With a Vibrating Mesh Nebulizer During Mechanical Ventilation: Does It Really Matter?
    Gilmore, Tim W.
    RESPIRATORY CARE, 2017, 62 (04) : 513 - 514
  • [8] PULMONARY DEPOSITION OF SALBUTAMOL AEROSOL DELIVERED BY METERED-DOSE INHALER (MDI), JET NEBULIZER AND ULTRASONIC NEBULIZER IH MECHANICALLY VENTILATED RABBITS
    FOK, TF
    ALESSA, MM
    MONKMAN, S
    DOLOVICH, BM
    COATES, G
    BOWEN, B
    KIRPALANI, HM
    PEDIATRIC RESEARCH, 1994, 36 (01) : A21 - A21
  • [9] Comparison of albuterol delivered by a metered dose inhaler with spacer versus a nebulizer in children with mild acute asthma
    Schuh, S
    Johnson, DW
    Stephens, D
    Callahan, S
    Winders, P
    Canny, GJ
    JOURNAL OF PEDIATRICS, 1999, 135 (01): : 22 - 27
  • [10] EFFECT OF THE HEATED HUMIDIFICATION ON THE IN VITRO AEROSOL DELIVERY WITH A PRESSURIZED-METERED DOSE INHALER AND WITH A VIBRATING MESH NEBULIZER IN MECHANICAL VENTILATION
    Eckes, Myriam
    Poree, Thierry
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2020, 33 (02) : A9 - A9