Comparison on characteristics of radiophotoluminescent glass dosemeters and thermoluminescent dosemeters

被引:60
作者
Hsu, Shih-Ming
Yeh, Shann-Horng
Lin, Meei-Shiow
Chen, Wei-Li
机构
[1] Natl Yang Ming Univ, Dept Med Radiat Technol, Taipei 112, Taiwan
[2] Tzu Chi Coll Technol, Dept Radiol Technol, Iwaki, Fukushima 970, Japan
[3] Inst Nucl Energy Res, Longtan 325, Taiwan
关键词
D O I
10.1093/rpd/nci510
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The radiophotoluminescent glass dosemeter (RPLGD) system is applicable for measurement of radiation dose of X rays and gamma rays by using radiophotoluminescent glass (silver-activated phosphate glass). When the radiophotoluminescent glass is exposed to ionizing radiation, stable luminescent centres are created. During pulsed ultraviolet laser excitation (337.1 nm) in the reader, the centres emit a radiation induced orange fluorescent light (600-700 nm). This phenomenon is called radiophotoluminescence. This study compared the RPLGD system with lithium fluoride (LiF) thermoluminescence dosimetry system and the results of the study revealed that the RPLGD had not only good basic characteristics for reproducibility of readout value, dose linearity, energy dependence and fading, but also infinite repeatable measurements and could be one of the most important radiation dose measurement instruments.
引用
收藏
页码:327 / 331
页数:5
相关论文
共 6 条
[1]   Measurements of Gamma-Knife helmet output factors using a radiophotoluminescent glass rod dosimeter and a diode detector [J].
Araki, F ;
Ikegami, T ;
Ishidoya, T ;
Kubo, HD .
MEDICAL PHYSICS, 2003, 30 (08) :1976-1981
[2]  
*AS TECHN GLASS CO, 2001, NEW RPL GLASS DOS SY
[3]  
*AS TECHN GLASS CO, 2000, TECHN INF RPL GLASS
[4]   New aspects of environmental monitoring using flat phosphate glass and thermoluminescence dosemeters [J].
Burgkhardt, B ;
Festag, JG ;
Piesch, E ;
Ugi, S .
RADIATION PROTECTION DOSIMETRY, 1996, 66 (1-4) :187-192
[5]  
PIESCH E, 1990, RADIAT PROT DOSIM, V33, P215
[6]  
PIESCH E, 1986, RADIAT PROT DOSIM, V17, P293