Developments of Dispersive Liquid-Liquid Microextraction Technique

被引:199
|
作者
Zang Xiao-Huan [1 ]
Wu Qiu-Hua [1 ]
Zhang Mei-Yue [1 ]
Xi Guo-Hong [1 ]
Wang Zhi [1 ]
机构
[1] Agr Univ Hebei, Key Lab Bioinorgan Chem, Coll Sci, Baoding 071001, Peoples R China
关键词
Dispersive liquid-liquid microextraction; sample pretreatment; review; ATOMIC-ABSORPTION-SPECTROMETRY; CHROMATOGRAPHY-MASS SPECTROMETRY; ENVIRONMENTAL WATER SAMPLES; SOLID-PHASE MICROEXTRACTION; FLAME PHOTOMETRIC DETECTION; ELECTRON-CAPTURE DETECTION; RAPID-DETERMINATION; ULTRA-TRACE; SIMULTANEOUS PRECONCENTRATION; ORGANOPHOSPHORUS PESTICIDES;
D O I
10.1016/S1872-2040(08)60082-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Dispersive liquid-liquid uncroextraction (DLLME) is a novel environmentally benign sample-preparation technique, possessing obvious advantages of simplicity of operation, low-cost, high enrichment factor and low consumption of organic solvent. Compared with single drop microextraction (SDME) and hollow fiber-based liquid-phase microextraction, the extraction time of DLLME is greatly shortened. DLLME coupled with gas chromatography, high performance liquid chromatography and atomic absorption spectrometry, etc., has been widely applied in the analysis of environmental and food samples. The basic principles, parameters affecting the extraction efficiency, and the latest applications of DLLME are reviewed.
引用
收藏
页码:161 / 168
页数:8
相关论文
共 53 条
  • [1] SOLID-PHASE MICROEXTRACTION WITH THERMAL-DESORPTION USING FUSED-SILICA OPTICAL FIBERS
    ARTHUR, CL
    PAWLISZYN, J
    [J]. ANALYTICAL CHEMISTRY, 1990, 62 (19) : 2145 - 2148
  • [2] Dispersive liquid-liquid microextraction combined with gas chromatography-flame photometric detection - Very simple, rapid and sensitive method for the determination of organophosphorus pesticides in water
    Berijani, Sana
    Assadi, Yaghoub
    Anbia, Mansoor
    Milani Hosseini, Mohammad-Reza
    Aghaee, Elham
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2006, 1123 (01) : 1 - 9
  • [3] Selenium analysis in water samples by dispersive liquid-liquid microextraction based on piazselenol formation and GC-ECD
    Bidari, Araz
    Hemmatkhah, Payam
    Jafarvand, Sanaz
    Hosseini, Mohammad Reza Milani
    Assadi, Yaghoub
    [J]. MICROCHIMICA ACTA, 2008, 163 (3-4) : 243 - 249
  • [4] Monitoring of selenium. in water samples using dispersive liquid-liquid microextraction followed by iridium-modified tube graphite furnace atomic absorption spectrometry
    Bidari, Araz
    Jahromi, Elham Zeini
    Assadi, Yaghoub
    Hosseini, Mohammad Reza Milani
    [J]. MICROCHEMICAL JOURNAL, 2007, 87 (01) : 6 - 12
  • [5] Speciation of butyl and phenyltin compounds using dispersive liquid-liquid microextraction and gas chromatography-flame photometric detection
    Birjandi, Afsoon Pajand
    Bidari, Araz
    Rezaei, Fatemeh
    Hosseini, Mohammad Reza Milani
    Assadi, Yaghoub
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2008, 1193 (1-2) : 19 - 25
  • [6] Focused microwave assistance for extracting some pesticide residues from strawberries into water before their determination by SPME/HPLC/DAD
    Cao, CF
    Wang, Z
    Urruty, L
    Pommier, JJ
    Montury, M
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2001, 49 (11) : 5092 - 5097
  • [7] Simultaneous derivatization and extraction of anilines in waste water with dispersive liquid-liquid microextraction followed by gas chromatography-mass spectrometric detection
    Chiang, Jing-Shan
    Huang, Shang-Da
    [J]. TALANTA, 2008, 75 (01) : 70 - 75
  • [8] Ionic liquid based dispersive liquid-liquid microextraction of aromatic amines in water samples
    Fan, Yun Chang
    Hu, Zheng Liang
    Chen, Mei Lan
    Tu, Chao Shen
    Zhu, Yan
    [J]. CHINESE CHEMICAL LETTERS, 2008, 19 (08) : 985 - 987
  • [9] Development of dispersive liquid-liquid microextraction combined with gas chromatography-mass spectrometry as a simple, rapid and highly sensitive method for the determination of phthalate esters in water samples
    Farahani, Hadi
    Norouzi, Parviz
    Dinarvand, Rassoul
    Ganjali, Mohammad Reza
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2007, 1172 (02) : 105 - 112
  • [10] Optimization of dispersive liquid-liquid microextraction of copper (II) by atomic absorption spectrometry as its oxinate chelate:: Application to determination of copper in different water samples
    Farajzadeh, Mir Ali
    Bahram, Morteza
    Mehr, Behzad Ghorbani
    Jonsson, Jan Ake
    [J]. TALANTA, 2008, 75 (03) : 832 - 840