Background suppression in frequency-domain fluorometry

被引:17
|
作者
Lakowicz, JR
Gryczynski, I
Gryczynski, Z
Johnson, ML
机构
[1] Univ Maryland, Sch Med, Baltimore, MD 21201 USA
[2] Univ Virginia, Dept Pharmacol, Charlottesville, VA 22908 USA
关键词
D O I
10.1006/abio.1999.4346
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Gated detection is often used in time-domain measurements of long-lived fluorophores for suppression of interfering short-lived autofluorescence. However, no direct method has been available for gated detection and background suppression when using frequency-domain fluorometry, We describe a direct method for real-time suppression of autofluorescence in frequency-domain fluorometry, The method uses a gated detector and the sample is excited by a pulsed train. The detector is gated on following each excitation pulse after a suitable time delay for decay of the prompt autofluorescence. Under the same experimental conditions a detectable reference signal is obtained by using a long lifetime standard with a known decay time. Because the sample and reference signals are measured under identical excitation, gating and instrumental conditions, the data can be analyzed as usual for frequency-domain data without further processing. We show by simulations that this method can be used to resolve single and multiexponential decays in the presence of short lifetime autofluorescence. (C) 2000 Academic Press.
引用
收藏
页码:74 / 85
页数:12
相关论文
共 50 条
  • [1] Frequency-domain fluorometry enhanced by real time background suppression
    Herman, P
    Maliwal, BP
    Lakowicz, JR
    BIOPHYSICAL JOURNAL, 2001, 80 (01) : 367A - 367A
  • [2] A METHOD FOR ONLINE BACKGROUND SUBTRACTION IN FREQUENCY-DOMAIN FLUOROMETRY
    REINHART, GD
    FEDDERSEN, B
    JAMESON, DM
    GRATTON, E
    BIOPHYSICAL JOURNAL, 1990, 57 (02) : A189 - A189
  • [3] SUBTRACTION OF BACKGROUND FLUORESCENCE IN MULTIHARMONIC FREQUENCY-DOMAIN FLUOROMETRY
    PERIASAMY, N
    VERKMAN, AS
    ANALYTICAL BIOCHEMISTRY, 1992, 201 (01) : 107 - 113
  • [4] Frequency-domain fluorometry in the presence of high in-phase background
    Vitta, P.
    Reklaitis, I.
    Zukauskas, A.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2012, 23 (03)
  • [5] Frequency-domain fluorometry.
    Nakaema, MKK
    Sanches, R
    QUIMICA NOVA, 1999, 22 (03): : 412 - 416
  • [6] DETECTOR NONLINEARITY IN FREQUENCY-DOMAIN FLUOROMETRY
    WIRTH, MJ
    BURBAGE, JD
    ZULLI, SL
    APPLIED OPTICS, 1993, 32 (06) : 976 - 980
  • [7] RECENT DEVELOPMENTS IN FREQUENCY-DOMAIN FLUOROMETRY
    LAKOWICZ, JR
    MALIWAL, BP
    GRATTON, E
    ANALYTICAL INSTRUMENTATION, 1985, 14 (3-4): : 193 - 223
  • [8] CORRECTION FOR CONTAMINANT FLUORESCENCE IN FREQUENCY-DOMAIN FLUOROMETRY
    LAKOWICZ, JR
    JAYAWEERA, R
    JOSHI, N
    GRYCZYNSKI, I
    ANALYTICAL BIOCHEMISTRY, 1987, 160 (02) : 471 - 479
  • [9] SYNTHESIZERS PHASE NOISE IN FREQUENCY-DOMAIN FLUOROMETRY
    BARBIERI, B
    DEPICCOLI, F
    GRATTON, E
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (10): : 3201 - 3206
  • [10] CORRECTION OF SYSTEMATIC PHASE ERRORS IN FREQUENCY-DOMAIN FLUOROMETRY
    POUGET, J
    MUGNIER, J
    VALEUR, B
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1989, 22 (10): : 855 - 862