Modular, self-assembling peptide linkers for stable and regenerable carbon nanotube biosensor interfaces

被引:16
作者
Contarino, Mark R.
Sergi, Mauro
Harrington, Adrian E.
Lazareck, Adam
Xu, Jimmy
Chaiken, Irwin
机构
[1] Drexel Univ, Coll Med, Dept Biochem & Mol Biol, Philadelphia, PA 19102 USA
[2] Drexel Univ, Sch Biomed Engn Sci & Hlth Syst, Philadelphia, PA 19104 USA
[3] Brown Univ, Div Engn, Providence, RI 02912 USA
关键词
coiled coils; carbon nanotubes; peptide linkers; biosensors;
D O I
10.1002/jmr.783
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
As part of an effort to develop nanoelectronic sensors for biological targets, we tested the potential to incorporate coiled coils as metallized, self-assembling, site-specific molecular linkers on carbon nanotubes (CNTs). Based on a previously conceived modular anchor-probe approach, a system was designed in which hydrophobic residues (valines and leucines) form the interface between the two helical peptide components. Charged residues (glutamates and arginines) on the borders of the hydrophobic interface increase peptide solubility, and provide stability and specificity for anchor-probe assembly. Two histidine residues oriented on the exposed hydrophilic exterior of each peptide were included as chelating sites for metal ions such as cobalt. Cysteines were incorporated at the peptide termini for oriented, thiol-mediated coupling to surface plasmon resonance (SPR) biosensor surfaces, gold nanoparticles or CNT substrates. The two peptides were produced by solid phase peptide synthesis using Fmoc chemistry: an acidic 42-residue peptide E42C, and its counterpart in the heterodimer, a basic 39-residue peptide R39C. The ability of E42C and R39C to bind cobalt was demonstrated by immobilized metal affinity chromatography and isothermal titration calorimetry. SPR biosensor kinetic analysis of dimer assembly revealed apparent sub-nanomolar affinities in buffers with and Without 1 mM CoCl2 using two different reference surfaces. For device-oriented CNT immobilization, R39C was covalently anchored to CNT tips via a C-terminal cysteine residue. Scanning electron microscopy was used to visualize the assembly of probe peptide (E42C) N-terminally labeled with 15 nm gold nanoparticles, when added to the R39C-CNT surface. The results obtained open the way to develop CNT tip-directed recognition surfaces, using recombinant and chemically synthesized chimeras containing binding epitopes fused to the E42C sequence domain. Copyright (c) 2006 John Wiley & Sons, Ltd.
引用
收藏
页码:363 / 371
页数:9
相关论文
共 52 条
[41]  
Saito R., 1998, PHYS PROPERTIES CARB
[42]   Proteins, recognition networks and developing interfaces for macromolecular biosensing [J].
Sergi, M ;
Zurawski, J ;
Cocklin, S ;
Chaiken, I .
JOURNAL OF MOLECULAR RECOGNITION, 2004, 17 (03) :198-208
[43]   AMINO-ACID SEQUENCE OF RABBIT SKELETAL TROPOMYOSIN AND ITS COILED COIL STRUCTURE [J].
SODEK, J ;
HODGES, RS ;
SMILLIE, LB ;
JURASEK, L .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1972, 69 (12) :3800-3804
[44]   Site-specific assembly of DNA and appended cargo on arrayed carbon nanotubes [J].
Taft, BJ ;
Lazareck, AD ;
Withey, GD ;
Yin, AJ ;
Xu, JM ;
Kelley, SO .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2004, 126 (40) :12750-12751
[45]   A SIMPLE CHEMICAL METHOD OF OPENING AND FILLING CARBON NANOTUBES [J].
TSANG, SC ;
CHEN, YK ;
HARRIS, PJF ;
GREEN, MLH .
NATURE, 1994, 372 (6502) :159-162
[46]   Peptide arrays with designed α-helical structures for characterization of proteins from FRET fingerprint patterns [J].
Usui, Kenji ;
Takahashi, Mizuki ;
Nokihara, Kiyoshi ;
Mihara, Hisakazu .
MOLECULAR DIVERSITY, 2004, 8 (03) :209-218
[47]   Enzyme-dispersed carbon-nanotube electrodes: a needle microsensor for monitoring glucose [J].
Wang, J ;
Musameh, M .
ANALYST, 2003, 128 (11) :1382-1385
[48]   SPOT synthesis:: Reliability of array-based measurement of peptide binding affinity [J].
Weiser, AA ;
Or-Guil, M ;
Tapia, V ;
Leichsenring, A ;
Schuchhardt, J ;
Frömmel, C ;
Volkmer-Engert, R .
ANALYTICAL BIOCHEMISTRY, 2005, 342 (02) :300-311
[49]   Ultra-high redox enzyme signal transduction using highly ordered carbon nanotube array electrodes [J].
Withey, GD ;
Lazareck, AD ;
Tzolov, MB ;
Yin, A ;
Aich, P ;
Yeh, JI ;
Xu, JM .
BIOSENSORS & BIOELECTRONICS, 2006, 21 (08) :1560-1565
[50]   Carbon nanotubes as assisted matrix for laser desorption/ionization time-of-flight mass spectrometry [J].
Xu, SY ;
Li, YF ;
Zou, HF ;
Qiu, JS ;
Guo, Z ;
Guo, BC .
ANALYTICAL CHEMISTRY, 2003, 75 (22) :6191-6195