Microbubble Composition and Preparation for High-Frequency Contrast-Enhanced Ultrasound Imaging: In Vitro and In Vivo Evaluation

被引:28
|
作者
Daeichin, Verya [1 ,4 ,5 ]
van Rooij, Tom [1 ]
Skachkov, Ilya [1 ,2 ]
Ergin, Bulent [7 ]
Specht, Patricia A. C. [8 ]
Lima, Alexandre [6 ]
Ince, Can [6 ,7 ]
Bosch, Johan G. [1 ]
van der Steen, Antonius F. W. [1 ,3 ,4 ]
de Jong, Nico [1 ,4 ,5 ]
Kooiman, Klazina [1 ]
机构
[1] Erasmus MC, Ctr Thorax, Dept Biomed Engn, NL-3000 CA Rotterdam, Netherlands
[2] Univ Med Ctr Utrecht, Imaging Div, NL-3508 GA Utrecht, Netherlands
[3] Shenzhen Inst Adv Technol, Shenzhen 518000, Peoples R China
[4] Delft Univ Technol, Lab Acoust Wavefield Imaging, Fac Sci Appl, NL-2628 CJ Delft, Netherlands
[5] Netherlands Heart Inst, NL-3511 EP Utrecht, Netherlands
[6] Erasmus MC, Dept Intens Care Adults, NL-3000 CA Rotterdam, Netherlands
[7] Acad Med Ctr, Dept Translat Physiol, NL-1100 DD Amsterdam, Netherlands
[8] Erasmus MC, Dept Anesthesiol, Lab Expt Anesthesiol, NL-3000 CA Rotterdam, Netherlands
关键词
Contrast agent; contrast-enhanced ultrasound (CEUS) imaging; high-frequency; in vitro; in vivo; microbubble; LIPID-COATED MICROBUBBLES; PHOSPHOLIPID ENCAPSULATED MICROBUBBLES; MICRO-ULTRASOUND; VISCOELASTIC PROPERTIES; TARGETED MICROBUBBLES; SUBHARMONIC RESPONSE; TUMOR ANGIOGENESIS; AGENTS; BEHAVIOR; SIZE;
D O I
10.1109/TUFFC.2016.2640342
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Although high-frequency ultrasound imaging is gaining attention in various applications, hardly any ultrasound contrast agents (UCAs) dedicated to such frequencies (>15 MHz) are available for contrast-enhanced ultrasound (CEUS) imaging. Moreover, the composition of the limited commercially available UCAs for high-frequency CEUS (hfCEUS) is largely unknown, while shell properties have been shown to be an important factor for their performance. The aim of our study was to produce UCAs in-house for hfCEUS. Twelve different UCA formulations A-L were made by either sonication or mechanical agitation. The gas core consisted of C4F10 and the main coating lipid was either 1,2-distearoyl-sn-glycero-3-phosphocholine (DSPC; A-F formulation) or 1,2-dipalmitoyl-sn-glycero-3-phosphocholine (DPPC; G-L formulation). Mechanical agitation resulted in UCAs with smaller microbubbles (number weighted mean diameter similar to 1 mu m) than sonication (number weighted mean diameter similar to 2 mu m). UCA formulations with similar size distributions but different main lipid components showed that the DPPC-based UCA formulations had higher nonlinear responses at both the fundamental and subharmonic frequencies in vitro for hfCEUS using the Vevo2100 high-frequency preclinical scanner (FUJIFILM VisualSonics, Inc.). In addition, UCA formulations F (DSPC-based) and L (DPPC-based) that were made by mechanical agitation performed similar in vitro to the commercially available TargetReady MicroMarker (FUJIFILM VisualSonics, Inc.). UCA formulation F also performed similar to Target-Ready MicroMarker in vivo in pigs with similar mean contrast intensity within the kidney (n = 7), but formulation L did not. This is likely due to the lower stability of formulation L in vivo. Our study shows that DSPC-based microbubbles produced by mechanical agitation resulted in small microbubbles with high nonlinear responses suitable for hfCEUS imaging.
引用
收藏
页码:555 / 567
页数:13
相关论文
共 50 条
  • [1] Microbubble Composition and Preparation for High-Frequency Contrast-Enhanced Ultrasound Imaging: In Vitro and In Vivo Evaluation (vol 64, pg 555, 2017)
    Daeichin, Verya
    van Rooij, Tom
    Skachkov, Ilya
    Ergin, Bulent
    Specht, Patricia A. C.
    Lima, Alexandre
    Ince, Can
    Bosch, Johan G.
    van der Steen, Antonius F. W.
    de Jong, Nico
    Kooiman, Klazina
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2021, 68 (06) : 2321 - 2321
  • [2] The Role of Microbubble Echo Phase Lag in Multipulse Contrast-Enhanced Ultrasound Imaging
    Tremblay-Darveau, Charles
    Sheeran, Paul S.
    Vu, Cindy Kim
    Williams, Ross
    Zhang, Ze
    Bruce, Matthew
    Burns, Peter N.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2018, 65 (08) : 1389 - 1401
  • [3] Contrast Imaging in Mouse Embryos Using High-frequency Ultrasound
    Denbeigh, Janet M.
    Nixon, Brian A.
    Puri, Mira C.
    Foster, F. Stuart
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2015, (97):
  • [4] A method for estimating the microbubble concentration in contrast-enhanced ultrasound imaging
    Sciallero, C.
    Crocco, M.
    Trucco, A.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2011, 22 (11)
  • [5] High-frequency Contrast-enhanced Ultrasound Imaging and Super-resolution Imaging of Rat Coronary Arteries
    Feng, Feng
    An, Jian
    Zhang, Jiabin
    Dong, Feihong
    Guo, Wenyu
    Huang, Shuo
    Zhang, Jue
    INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS 2021), 2021,
  • [6] Contrast-enhanced high-frequency ultrasound imaging of early stage liver metastasis in a preclinical mouse model
    Horie, Sachiko
    Chen, Rui
    Li, Li
    Mori, Shiro
    Kodama, Tetsuya
    CANCER LETTERS, 2013, 339 (02) : 208 - 213
  • [7] In Vivo High-Frequency, Contrast-Enhanced Ultrasonography of Uveal Melanoma in Mice: Imaging Features and Histopathologic Correlations
    Zhang, Qing
    Yang, Hua
    Kang, Shin J.
    Wang, Yanggan
    Wang, Geoffrey D.
    Coulthard, Tonya
    Grossniklaus, Hans E.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (05) : 2662 - 2668
  • [8] VERY LOW FREQUENCY RADIAL MODULATION FOR DEEP PENETRATION CONTRAST-ENHANCED ULTRASOUND IMAGING
    Jing, Bowen
    Lindsey, Brooks D.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2022, 48 (03) : 530 - 545
  • [9] Contrast-Enhanced Ultrasound With Perflubutane Microbubble Agent: Evaluation of Differentiation of Hepatocellular Carcinoma
    Takahashi, Masanori
    Maruyama, Hitoshi
    Ishibashi, Hiroyuki
    Yoshikawa, Masaharu
    Yokosuka, Osamu
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (02) : W123 - W131
  • [10] Three-dimensional evaluation of microvascular networks using contrast-enhanced ultrasound and microbubble tracking
    Johnson, Kenneth
    Oezdemir, Ipek
    Hoyt, Kenneth
    PROCEEDINGS OF THE 2020 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2020,