A state-of-art review on antenna designs for ingestible application

被引:6
作者
Neebha, T. Mary [1 ]
Andrushia, A. Diana [1 ]
Durga, S. [2 ]
机构
[1] Karunya Inst Technol & Sci, Dept Elect & Commun Engn, Coimbatore, Tamil Nadu, India
[2] Karunya Inst Technol & Sci, Dept Comp Sci & Engn, Coimbatore, Tamil Nadu, India
关键词
Ingestible antenna; Wireless Capsule Endoscopy; Biodegradable materials; IoT; miniaturization; Surface waves; CAPSULE ANTENNA; PATCH ANTENNA; LOOP ANTENNA; SYSTEM; COMPRESSION; REDUCTION; RADIATION; MEDRADIO;
D O I
10.1080/15368378.2020.1821707
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Research interest in ingestible Wireless Capsule Endoscopy (WCE) studies in humans showed better results than conventional invasive probe endoscopy methods. Because of the structure and the position of the small intestine, proper scanning cannot be done in the area using traditional endoscopic methods. For patient comfort, continuous developments have been suggested in capsule endoscopy designs in terms of the quality of images transmitted, capsule orientation, positioning of the capsule from outside the body, link budget analysis, impedance matching and capsule miniaturization. To improve the image quality, transmission efficiency of the antenna has to be improved. This has led to the development of many antenna structures in an ingestible capsule system. Literatures have identified Med Radio and ISM (Industrial, Scientific and Medical) band as operation bands for the WCE systems. This review aims to highlight: (1) design considerations for various antenna types, (2) miniaturization techniques, (3) operating bands, specifications and various design challenges and (4) research gap, advanced design technologies and targets of ingestible antenna system. The main aim of this paper is to tutorial the up-to-date information on the recent antenna designing techniques and challenges for ingestible system.
引用
收藏
页码:387 / 402
页数:16
相关论文
共 81 条
[1]   The development of a clinically tested visually lossless Image compression system for capsule endoscopy [J].
Al-Shebani, Qasim ;
Premaratne, Prashan ;
Vial, Peter James ;
McAndrew, Darryl J. .
SIGNAL PROCESSING-IMAGE COMMUNICATION, 2019, 76 :135-150
[2]   Are Current Advances of Compression Algorithms for Capsule Endoscopy Enough? A Technical Review [J].
Alam, Mohammad Wajih ;
Hasan, Md. Mehedi ;
Mohammed, Shahed Khan ;
Deeba, Farah ;
Wahid, Khan A. .
IEEE Reviews in Biomedical Engineering, 2017, 10 :26-43
[3]   FUNDAMENTAL SUPERSTRATE (COVER) EFFECTS ON PRINTED-CIRCUIT ANTENNAS [J].
ALEXOPOULOS, NG ;
JACKSON, DR .
IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 1984, 32 (08) :807-816
[4]   Flexible meandered loop antenna for implants in MedRadio and ISM bands [J].
Alrawashdeh, R. ;
Huang, Y. ;
Cao, P. .
ELECTRONICS LETTERS, 2013, 49 (24) :1515-1516
[5]   A Broadband Flexible Implantable Loop Antenna With Complementary Split Ring Resonators [J].
Alrawashdeh, Rula S. ;
Huang, Yi ;
Kod, Muayad ;
Sajak, Aznida Abu Bakar .
IEEE ANTENNAS AND WIRELESS PROPAGATION LETTERS, 2015, 14 :1506-1509
[6]  
ALSATH M, 2013, IEEE ANTENN WIREL PR
[7]  
[Anonymous], 2010, NATURE MAT, V9, pS5
[8]  
Arefin MS, 2016, IEEE ENG MED BIO, P3031, DOI 10.1109/EMBC.2016.7591368
[9]   A Small Implantable Antenna for MedRadio and ISM Bands [J].
Asili, Mustafa ;
Green, Ryan ;
Seran, Santosh ;
Topsakal, Erdem .
IEEE ANTENNAS AND WIRELESS PROPAGATION LETTERS, 2012, 11 :1683-1685
[10]  
Bakogianni S, 2015, IEEE ANTENNAS PROP, P770, DOI 10.1109/APS.2015.7304772