Improved. T2*assessment in liver iron overload by magnetic resonance imaging

被引:119
作者
Positano, Vincenzo [1 ]
Salani, Benedetta [1 ]
Pepe, Alessia [1 ]
Santarelli, Maria Filomena [1 ,2 ]
De Marchi, Daniele [1 ]
Ramazzotti, Anna [1 ,2 ]
Favilli, Brunella [1 ,2 ]
Cracolici, Eliana [3 ]
Midiri, Massimo [3 ]
Clanciulli, Paolo [4 ]
Lombardi, Massimo [1 ]
Landini, Luigi [1 ,5 ]
机构
[1] Gabriele Monasterio Fdn, MRI Lab, I-56124 Pisa, Italy
[2] CNR, Inst Clin Physiol, I-56124 Pisa, Italy
[3] Univ Palermo, Dept Radiol, I-90010 Palermo, Italy
[4] St Eugenio Papa Hosp, Ctr Talassemie, I-00100 Rome, Italy
[5] Univ Pisa, Dept Informat Engn, I-56126 Pisa, Italy
关键词
Liver; Thalassemia; MRI; Iron overload; Multi-echo T2*; THALASSEMIA MAJOR; BETA-THALASSEMIA; IN-VIVO; MRI; DEFERIPRONE; SEGMENTATION; DEFEROXAMINE; DIAGNOSIS; STORES;
D O I
10.1016/j.mri.2008.06.004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In the clinical MRI practice, it is common to assess liver iron overload by T2* multi-echo gradient-echo images. However, there is no full consensus about the best image analysis approach for the T2* measurements. The currently used methods involve manual drawing of a region of interest (ROI) within MR images of the liver. Evaluation of a representative liver T2* value is done by fitting an appropriate model to the signal decay within the ROIs vs. the echo time. The resulting T2* value may depend on both ROI placement and choice of the signal decay model. The aim of this study was to understand how the choice of the analysis methodology may affect the accuracy of T2* measurements. A software model of the iron overloaded liver was inferred from MR images acquired from 40 thalassemia major patients. Different image L analysis methods were compared exploiting the developed software model. Moreover, a method for global semiautomatic T2* measurement involving the whole liver was developed. The global method included automatic segmentation of parenchyma by an adaptive fuzzy-clustering algorithm able to compensate for signal inhomogeneities. Global liver T2* value was evaluated using a pixel-wise technique and an optimized signal decay model. The global approach was compared with the ROI-based approach used in the clinical practice. For the ROI-based approach, the intra-observer and inter-observer coefficients of variation (CoVs) were 3.7% and 5.6%, respectively. For the global analysis, the CoVs for intra-observers and inter-observers reproducibility were 0.85% and 2.87%, respectively. The variability shown by the ROI-based approach was acceptable for use in the clinical practice; however, the developed global method increased the accuracy in T2* assessment and significantly reduced the operator dependence and sampling errors. This global approach Could be useful in the clinical arena for patients with borderline liver iron overload and/or requiring follow-up studies. (C) 2009 Elsevier Inc. All rights reserved.
引用
收藏
页码:188 / 197
页数:10
相关论文
共 27 条
[1]   Cardiovascular T2-star (T2*) magnetic resonance for the early diagnosis of myocardial iron overload [J].
Anderson, LJ ;
Holden, S ;
Davis, B ;
Prescott, E ;
Charrier, CC ;
Bunce, NH ;
Firmin, DN ;
Wonke, B ;
Porter, J ;
Walker, JM ;
Pennell, DJ .
EUROPEAN HEART JOURNAL, 2001, 22 (23) :2171-2179
[2]   Hepatic iron concentration and total body iron stores in thalassemia major. [J].
Angelucci, E ;
Brittenham, GM ;
McLaren, CE ;
Ripalti, M ;
Baronciani, D ;
Giardini, C ;
Galimberti, M ;
Polchi, P ;
Lucarelli, G .
NEW ENGLAND JOURNAL OF MEDICINE, 2000, 343 (05) :327-331
[3]   Combination of signals from array coils using image-based estimation of coil sensitivity profiles [J].
Bydder, M ;
Larkman, DJ ;
Hajnal, JV .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (03) :539-548
[4]   Signal-to-noise measurements in magnitude images from NMR phased arrays [J].
Constantinides, CD ;
Atalar, E ;
McVeigh, ER .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (05) :852-857
[5]  
DENDEKKER AJ, 2005, ADV IMAGE PROCESSING, P106
[6]  
Emond MJ, 1999, CLIN CHEM, V45, P340
[7]   Potential myocardial iron content evaluation by magnetic resonance imaging in thalassemia major patients treated with deferoxamine or deferiprone during a randomized multicenter prospective clinical study [J].
Galia, M ;
Midiri, M ;
Bartolotta, V ;
Morabito, A ;
Rizzo, M ;
Mangiagli, A ;
Malizia, R ;
Borsellino, Z ;
Capra, M ;
D'Ascola, DG ;
Magnano, C ;
Gerardi, C ;
Rigano, P ;
Maggio, A .
HEMOGLOBIN, 2003, 27 (02) :63-76
[8]   Non-invasive assessment of hepatic iron stores by MRI [J].
Gandon, Y ;
Olivié, D ;
Guyader, D ;
Aubé, C ;
Oberti, F ;
Sebille, V ;
Deugnier, Y .
LANCET, 2004, 363 (9406) :357-362
[9]   Improved R2* measurements in myocardial iron overload [J].
Ghugre, NR ;
Enriquez, CM ;
Coates, TD ;
Nelson, MD ;
Wood, JC .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 23 (01) :9-16
[10]   Mechanisms of tissue-iron relaxivity: Nuclear magnetic resonance studies of human liver biopsy specimens [J].
Ghugre, NR ;
Coates, TD ;
Nelson, MD ;
Wood, JC .
MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (05) :1185-1193