Measurements of endotoxin on ambient loaded PM filters after long-term storage

被引:5
作者
Morgenstern, Verena
Bischof, Wolfgang
Koch, Andrea
Heinrich, Joachim
机构
[1] GSF Natl Res Ctr Environm & Hlth, Inst Epidemiol, D-85764 Neuherberg, Germany
[2] Univ Munich, Inst Med Data Management Biometr & Epidemiol Muni, D-80539 Munich, Germany
[3] Univ Jena, Inst Occupat Social & Environm Med & Hyg, Dept Indoor Climatol, D-07743 Jena, Germany
关键词
endotoxin; outdoor; bacteria; particulate matter; storage of PM-filters;
D O I
10.1016/j.scitotenv.2006.08.027
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
At present there exist unsolved questions, whether endotoxin measurements on PM filters show valid measurements after long-term storage of loaded PM filters. As part of the TRAPCA study we collected particles with a 50% aerodynamic cut-off diameter of 2.5 mu m (PM2.5) at 40 outdoor sites and particles less than 10 pm in size (PM 10) at a subset of these sites (N=12) in Munich. The PM filters were cut in halves and endotoxin was measured in the extract of one filter half 2-3 years after PM collection. Here we present the results of repeated endotoxin measurements, where the association between previously measured endotoxin concentrations, measurements from stored eluates, and measurements in extracts of the second filter halves were determined. No statistically significant changes were seen between our old measurements and those from the stored eluates. Additionally, no change was observed between previously measured endotoxin concentrations and those from the stored set of filter halves. We found an average increase of 5% between our old measurements and those from the stored eluates and of 19% between the old measurements and those from the stored set of filter halves. The correlations between the previously measured endotoxin concentrations and the repeated measurements from the stored eluates were high (r=0.789) for EU/m(3) PM2.5. Since endotoxin was evaluated from the same set of filter halves, it is obvious that storage over three years did not substantially effect the correlation of the endotoxin content. Regarding the outliers from previous measurements unsymmettic endotoxin spots on one out of 48 filter halves could be determined. Apart from this we conclude that the endotoxin is homogenously distributed on the filter halves and that endotoxin levels, which were repeatedly measured from filters stored over three years, could be determined validly. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:574 / 579
页数:6
相关论文
共 21 条
  • [1] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [2] Estimating long-term average particulate air pollution concentrations: Application of traffic indicators and geographic information systems
    Brauer, M
    Hoek, G
    van Vliet, P
    Meliefste, K
    Fischer, P
    Gehring, U
    Heinrich, J
    Cyrys, J
    Bellander, T
    Lewne, M
    Brunekreef, B
    [J]. EPIDEMIOLOGY, 2003, 14 (02) : 228 - 239
  • [3] Environmental exposure to endotoxin and its relation to asthma in school-age children
    Braun-Fahrländer, C
    Riedler, J
    Herz, U
    Eder, W
    Waser, M
    Grize, L
    Maisch, S
    Carr, D
    Gerlach, F
    Bufe, A
    Lauener, RP
    Schierl, R
    Renz, H
    Nowak, D
    von Mutius, E
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2002, 347 (12) : 869 - 877
  • [4] Epidemiological evidence of effects of coarse airborne particles on health
    Brunekreef, B
    Forsberg, B
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2005, 26 (02) : 309 - 318
  • [5] Seasonal variability of endotoxin in ambient fine particulate matter
    Carty, CL
    Gehring, U
    Cyrys, J
    Bischof, W
    Heinrich, J
    [J]. JOURNAL OF ENVIRONMENTAL MONITORING, 2003, 5 (06): : 953 - 958
  • [6] Comparison between different traffic-related particle indicators:: Elemental. carbon (EC), PM2.5 mass, and absorbance
    Cyrys, J
    Heinrich, J
    Hoek, G
    Meliefste, K
    Lewné, M
    Gehring, U
    Bellander, T
    Fischer, P
    Van Vliet, P
    Brauer, M
    Wichmann, HE
    Brunekreef, B
    [J]. JOURNAL OF EXPOSURE ANALYSIS AND ENVIRONMENTAL EPIDEMIOLOGY, 2003, 13 (02): : 134 - 143
  • [7] Potential mechanisms of adverse pulmonary and cardiovascular effects of particulate air pollution (PM10)
    Donaldson, K
    MacNee, W
    [J]. INTERNATIONAL JOURNAL OF HYGIENE AND ENVIRONMENTAL HEALTH, 2001, 203 (5-6) : 411 - 415
  • [8] (1→3)-β-D-glucans and respiratory health:: a review of the scientific evidence
    Douwes, J
    [J]. INDOOR AIR, 2005, 15 (03) : 160 - 169
  • [9] INFLUENCE OF VARIOUS DUST SAMPLING AND EXTRACTION METHODS ON THE MEASUREMENT OF AIRBORNE ENDOTOXIN
    DOUWES, J
    VERSLOOT, P
    HOLLANDER, A
    HEEDERIK, D
    DOEKES, G
    [J]. APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1995, 61 (05) : 1763 - 1769
  • [10] The effect of storage on allergen and microbial agent levels in frozen house dust
    Fahlbusch, B
    Koch, A
    Douwes, J
    Bischof, W
    Gehring, U
    Richter, K
    Wichmann, HE
    Heinrich, J
    [J]. ALLERGY, 2003, 58 (02) : 150 - 153