Determination of indium using vortex assisted solid phase microextraction based on oleic acid coated magnetic nanoparticles combined with slotted quartz tube-flame atomic absorption spectrometry

被引:23
作者
Celik, Birgul [1 ]
Akkaya, Erhan [2 ]
Bakirdere, Sezgin [2 ]
Aydin, Firat [1 ]
机构
[1] Dicle Univ, Sci Fac, Chem Dept, Diyarbakir, Turkey
[2] Yildiz Tech Univ, Fac Art & Sci, Chem Dept, Istanbul, Turkey
关键词
Indium; Magnetic nanoparticles; Oleic acid; Slotted quartz tube; Flame atomic absorption spectroscopy; LIQUID-LIQUID MICROEXTRACTION; PLASMA-MASS SPECTROMETRY; ULTRATRACE LEVELS; TRACE AMOUNTS; ICP-MS; CADMIUM; SAMPLES; WATER; PRECONCENTRATION; EXTRACTION;
D O I
10.1016/j.microc.2018.04.031
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A solid phase microextraction (SPME) method combined with slotted quartz tube-flame atomic absorption spectrometry (SQT-FAAS) was developed and optimized for the extraction and the determination of trace indium in different matrices. The method relies upon SPME that uses oleic acid coated magnetite nanoparticles (MNPs) followed by analysis with SQT mounted FAAS. After the enhancement in sensitivity by means of SPME, further improvement in sensitivity was provided by SQT which improves the detection power of conventional FAAS. The easy separation of extracted indium from the media was facilitated using an external magnetic field. Some effective parameters on the development of the method such as pH of the analyte solution, amount of eluent, amount of MNPs were optimized to obtain maximum absorbance value at each optimization step in order to achieve an improved detection power. Under the optimum experimental and instrumental conditions, the enhancement factor of 44 was obtained where the limit of detection and the limit of quantification were found to be 6.02 mu g/L and 20.06 mu g/L, respectively. Recovery tests were also studied in order to demonstrate the accuracy of the developed analytical method and satisfactory outcomes were obtained.
引用
收藏
页码:7 / 11
页数:5
相关论文
共 26 条
[1]   Determination of organophosphorus pesticides in water samples by single drop microextraction and gas chromatography-flame photometric detector [J].
Ahmadi, F ;
Assadi, Y ;
Hosseini, SMRM ;
Rezaee, M .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1101 (1-2) :307-312
[2]   A new method for the determination of cadmium at ultratrace levels using slotted quartz tube-flame atomic absorption spectrometry after preconcentration with stearic acid coated magnetite nanoparticles [J].
Akkaya, Erhan ;
Kasa, Nursu Aylin ;
Cetin, Guelten ;
Bakirdere, Sezgin .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2017, 32 (12) :2433-2438
[3]   Sensitive determination of cadmium using solidified floating organic drop microextraction-slotted quartz tube-flame atomic absorption spectroscopy [J].
Akkaya, Erhan ;
Chormey, Dotse Selali ;
Bakirdere, Sezgin .
ENVIRONMENTAL MONITORING AND ASSESSMENT, 2017, 189 (10)
[4]   Indium determination using slotted quartz tube-atom trap-flame atomic absorption spectrometry and interference studies [J].
Arslan, Yasin ;
Kenduzler, Erdal ;
Ataman, O. Yavuz .
TALANTA, 2011, 85 (04) :1786-1791
[5]   Determination of Lead in Drinking and Wastewater by Hydride Generation Atomic Absorption Spectrometry [J].
Bakirdere, Sezgin ;
Chormey, Dotse Selali ;
Buyukpinar, Cagdas ;
San, Nevim ;
Keyf, Seyfullah .
ANALYTICAL LETTERS, 2016, 49 (12) :1917-1925
[6]   Separation of gallium and indium from ores matrix by sorption on Amberlite XAD-2 coated with PAM [J].
Bermejo-Barrera, P ;
Martínez-Alsonso, N ;
Bermejo-Barrera, A .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 369 (02) :191-194
[7]   Determination of nickel in water and soil samples at trace levels using photochemical vapor generation-batch type ultrasonication assisted gas liquid separator-atomic absorption spectrometry [J].
Buyukpinar, Cagdas ;
Maltepe, Esra ;
Chormey, Dotse Selali ;
San, Nevin ;
Bakirdere, Sezgin .
MICROCHEMICAL JOURNAL, 2017, 132 :167-171
[8]   Mechanisms and factors for edible oil oxidation [J].
Choe, Eunok ;
Min, David B. .
COMPREHENSIVE REVIEWS IN FOOD SCIENCE AND FOOD SAFETY, 2006, 5 (04) :169-186
[9]   2-(2-THIAZOLYLAZO)-P-CRESOL (TAC) AS A REAGENT FOR THE SPECTROPHOTOMETRIC DETERMINATION OF INDIUM(III) [J].
FERREIRA, SLC ;
COSTA, ACS ;
ANDRADE, HAS .
MICROCHEMICAL JOURNAL, 1991, 44 (01) :63-66
[10]   Simultaneous measurement of the trace elements Al, As, B, Be, Cd, Co, Cu, Fe, Li, Mn, Mo, Ni, Rb, Se, Sr, and Zn in human serum and their reference ranges by ICP-MS [J].
Forrer, R ;
Gautschi, K ;
Lutz, H .
BIOLOGICAL TRACE ELEMENT RESEARCH, 2001, 80 (01) :77-93