Performance of TMDs on nonlinear structures subjected to near-fault earthquakes

被引:0
作者
Domizio, Martin [1 ,2 ]
Ambrosini, Daniel [1 ,2 ]
Curadelli, Oscar [1 ,2 ]
机构
[1] Natl Univ Cuyo, Fac Engn, Struct Engn Master Program, Mendoza, Argentina
[2] Natl Res Council Argentina, CONICET, Buenos Aires, DF, Argentina
关键词
tuned mass damper; near fault earthquakes; collapse; non-linear dynamic analyses; TUNED-MASS DAMPERS; GROUND MOTION PULSES; VIBRATION CONTROL; INELASTIC STRUCTURES; SEISMIC PERFORMANCE; DESIGN; EXCITATIONS; BUILDINGS; COLLAPSE; SYSTEMS;
D O I
10.12989/sss.2015.16.4.725
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Tuned mass dampers (TMD) are devices employed in vibration control since the beginning of the twentieth century. However, their implementation for controlling the seismic response in civil structures is more recent. While the efficiency of TMD on structures under far-field earthquakes has been demonstrated, the convenience of its employment against near-fault earthquakes is still under discussion. In this context, the study of this type of device is raised, not as an alternative to the seismic isolation, which is clearly a better choice for new buildings, but rather as an improvement in the structural safety of existing buildings. Seismic records with an impulsive character have been registered in the vicinity of faults that cause seismic events. In this paper, the ability of TMD to control the response of structures that experience inelastic deformations and eventually reach collapse subject to the action of such earthquakes is studied. The results of a series of nonlinear dynamic analyses are presented. These analyses are performed on a numerical model of a structure under the action of near-fault earthquakes. The structure analyzed in this study is a steel frame which behaves as a single degree of freedom (SDOF) system. TMD with different mass values are added on the numerical model of the structure, and the TMD performance is evaluated by comparing the response of the structure with and without the control device.
引用
收藏
页码:725 / 742
页数:18
相关论文
共 50 条
[41]   Seismic damage analysis of Yematan Bridge under near-fault earthquakes [J].
Zu, Lin ;
Huang, Yong ;
Li, Wenshan ;
Zhang, Haoyu ;
Cai, Liwen .
STRUCTURES, 2022, 41 :586-601
[42]   Dimensional response analysis of rocking wall-frame building structures with control devices subjected to near-fault pulse-like ground motions [J].
Guo, Guiqiang ;
Qin, Leibo ;
Yang, Dixiong ;
Liu, Yunhe .
ENGINEERING STRUCTURES, 2020, 220
[43]   Seismic Responses of Isolated Structures with Mass Asymmetry Mounted on TCFP Subjected to Near-Fault Ground Motions [J].
Tajammolian, Hamed ;
Khoshnoudian, Faramarz ;
Mehr, Nasim Partovi .
INTERNATIONAL JOURNAL OF CIVIL ENGINEERING, 2016, 14 (8A) :573-584
[44]   Energy dissipation by friction for sliding blocks subjected to near-fault seismic base motion [J].
Barlek Mendoza, Pablo M. ;
Ambrosini, Daniel ;
Luccioni, Bibiana M. .
SMART STRUCTURES AND SYSTEMS, 2021, 27 (05) :819-836
[45]   Seismic Fragility Analysis of Base Isolated Structure Subjected to Near-fault Ground Motions [J].
Liu, Chengqing ;
Fang, Dengjia ;
Yan, Zhengxi .
PERIODICA POLYTECHNICA-CIVIL ENGINEERING, 2021, 65 (03) :768-783
[46]   Near-fault effects on residual displacements of RC structures [J].
Liossatou, Eftychia ;
Fardis, Michael N. .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2016, 45 (09) :1391-1409
[47]   Seismic performance of RC frame structures with buckling-restrained brace subjected to near-fault pulse-like ground motions [J].
Bai J. ;
Cheng F. ;
Jin S. ;
Pan Y. ;
Zhao J. .
Jianzhu Jiegou Xuebao/Journal of Building Structures, 2018, 39 :103-110
[48]   The dynamic response and seismic damage of single-layer reticulated shells subjected to near-fault ground motions [J].
Zhang, Ming ;
Parke, Gerry ;
Chang, Zhiwang .
EARTHQUAKES AND STRUCTURES, 2018, 14 (05) :399-409
[49]   Sliding-LRB incorporating superelastic SMA for seismic protection of bridges under near-fault earthquakes: A comparative study [J].
Zheng, Wenzhi ;
Tan, Ping ;
Li, Jian ;
Wang, Hao ;
Tan, Jiajun .
SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2022, 155
[50]   Self-Tuning Fuzzy Control for Seismic Protection of Smart Base-Isolated Buildings Subjected to Pulse-Type Near-Fault Earthquakes [J].
Zhao, Dahai ;
Liu, Yang ;
Li, Hongnan .
APPLIED SCIENCES-BASEL, 2017, 7 (02)