Accuracy, Precision, and Reproducibility of Four T1 Mapping Sequences: A Head-to-Head Comparison of MOLLI, ShMOLLI, SASHA, and SAPPHIRE

被引:249
作者
Roujol, Sebastien [1 ]
Weingaertner, Sebastian [1 ]
Foppa, Murilo [1 ]
Chow, Kelvin [4 ]
Kawaji, Keigo [1 ]
Ngo, Long H. [1 ]
Kellman, Peter [5 ]
Manning, Warren J. [1 ,2 ,3 ]
Thompson, Richard B. [4 ]
Nezafat, Reza [1 ]
机构
[1] Beth Israel Deaconess Med Ctr, Dept Med, Div Cardiovasc, Boston, MA 02215 USA
[2] Beth Israel Deaconess Med Ctr, Dept Radiol, Boston, MA 02215 USA
[3] Harvard Univ, Sch Med, Boston, MA 02215 USA
[4] Univ Alberta, Fac Med & Dent, Dept Biomed Engn, Edmonton, AB, Canada
[5] NHLBI, NIH, Bethesda, MD 20892 USA
基金
美国国家卫生研究院;
关键词
CARDIOVASCULAR MAGNETIC-RESONANCE; GADOPENTETATE DIMEGLUMINE; MYOCARDIAL FIBROSIS; VOLUME; QUANTIFICATION; ACQUISITION;
D O I
10.1148/radiol.14140296
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare accuracy, precision, and reproducibility of four commonly used myocardial T1 mapping sequences: modified Look-Locker inversion recovery (MOLLI), shortened MOLLI (ShMOLLI), saturation recovery single-shot acquisition (SASHA), and saturation pulse prepared heart rate independent inversion recovery (SAPPHIRE). Materials and Methods: This HIPAA-compliant study was approved by the institutional review board. All subjects provided written informed consent. Accuracy, precision, and reproducibility of the four T1 mapping sequences were first compared in phantom experiments. In vivo analysis was performed in seven healthy subjects (mean age 6 standard deviation, 38 years +/- 19; four men, three women) who were imaged twice on two separate days. In vivo reproducibility of native T1 mapping and extracellular volume (ECV) were measured. Differences between the sequences were assessed by using Kruskal-Wallis and Wilcoxon rank sum tests (phantom data) and mixed-effect models (in vivo data). Results: T1 mapping accuracy in phantoms was lower with ShMOLLI (62 msec) and MOLLI (44 msec) than with SASHA (13 msec; P < .05) and SAPPHIRE (12 msec; P,.05). MOLLI had similar precision to ShMOLLI (4.0 msec vs 5.6 msec; P = .07) but higher precision than SAPPHIRE (6.8 msec; P = .002) and SASHA (8.7 msec; P < .001). All sequences had similar reproducibility in phantoms (P = .1). The four sequences had similar in vivo reproducibility for native T1 mapping (similar to 25-50 msec; P > .05) and ECV quantification (similar to 0.01-0.02; P > .05). Conclusion: SASHA and SAPPHIRE yield higher accuracy, lower precision, and similar reproducibility compared with MOLLI and ShMOLLI for T1 measurement. Different sequences yield different ECV values; however, all sequences have similar reproducibility for ECV quantification. (C),RSNA, 2014.
引用
收藏
页码:683 / 689
页数:7
相关论文
共 28 条
[1]   Measurement of the distribution volume of gadopentetate dimeglumine at echo-planar MR imaging to quantify myocardial infarction:: Comparison with 99mTc-DTPA autoradiography in rats [J].
Arheden, H ;
Saeed, M ;
Higgins, CB ;
Gao, DW ;
Bremerich, J ;
Wyttenbach, R ;
Dae, MW ;
Wendland, MF .
RADIOLOGY, 1999, 211 (03) :698-708
[2]  
Chow K, 2012, MAGNETIC RESONANCE M, P3288
[3]  
Chow K., 2013, Magn Reson Med
[4]  
Chow K., 2012, J Cardiovasc Magn Reson, V14, pP281, DOI DOI 10.1186/1532-429X-14-S1-P281
[5]  
Clique H, 2013, MAGN RESON MED
[6]   Multiple 3D Inversion Recovery Imaging for Volume T1 Mapping of the Heart [J].
Coniglio, A. ;
Di Renzi, P. ;
Freixas, G. Vilches ;
Della Longa, G. ;
Santarelli, A. ;
Capparella, R. ;
Nardiello, B. ;
Loiudice, C. ;
Bianchi, S. ;
D'Arienzo, M. ;
Begnozzi, L. .
MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (01) :163-170
[7]   Three-dimensional T1 mapping of the mouse heart using variable flip angle steady-state MR imaging [J].
Coolen, Bram F. ;
Geelen, Tessa ;
Paulis, Leonie E. M. ;
Nauerth, Arno ;
Nicolay, Klaas ;
Strijkers, Gustav J. .
NMR IN BIOMEDICINE, 2011, 24 (02) :154-162
[8]   Flip angle profile correction for T1 and T2 quantification with look-locker inversion recovery 2D steady-state free precession imaging [J].
Cooper, Mitchell A. ;
Nguyen, Thanh D. ;
Spincemaille, Pascal ;
Prince, Martin R. ;
Weinsaft, Jonathan W. ;
Wang, Yi .
MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (05) :1579-1585
[9]   Arrhythmia Insensitive Rapid Cardiac T1 Mapping Pulse Sequence [J].
Fitts, Michelle ;
Breton, Elodie ;
Kholmovski, Eugene G. ;
Dosdall, Derek J. ;
Vijayakumar, Sathya ;
Hong, Kyung P. ;
Ranjan, Ravi ;
Marrouche, Nassir F. ;
Axel, Leon ;
Kim, Daniel .
MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (05) :1274-1282
[10]   Measurement of the gadopentetate dimeglumine partition coefficient in human myocardium in vivo: Normal distribution and elevation in acute and chronic infarction [J].
Flacke, SJ ;
Fischer, SE ;
Lorenz, CH .
RADIOLOGY, 2001, 218 (03) :703-710