What is the best similarity measure for motion correction in fMRI time series?

被引:300
|
作者
Freire, L [1 ]
Roche, A
Mangin, JF
机构
[1] CEA, Serv Hosp Frederic Joliot, F-91401 Orsay, France
[2] FCUL, Dept Biofis & Engn Biomed, P-1749016 Lisbon, Portugal
[3] FML, Inst Nucl Med, P-1649028 Lisbon, Portugal
[4] INRIA, Epidaure Project, Sophia Antipolis, France
[5] Univ Oxford, Med Vis Lab, Oxford OX2 7BZ, England
关键词
artifact; fMRI; motion correction; robust registration; spurious activation;
D O I
10.1109/TMI.2002.1009383
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
It has been shown that the difference of squares cost function used by standard realignment packages (SENT and AIR) can lead to the detection of spurious activations, because the motion parameter estimations are biased by the activated areas. Therefore, this paper describes several experiments aiming at selecting a better similarity measure to drive functional magnetic resonance image registration. The behaviors of the Geman-McClure (GM) estimator, of the correlation ratio, and of the mutual information (MI) relative to activated areas are studied using simulated time series and actual data stemming from a 3T magnet. It is shown that these methods are more robust than the usual difference of squares measure. The results suggest also that the measures built from robust metrics like the GM estimator may be the best choice, while MI is also an interesting solution. Some more work, however, is required to compare the various robust metrics proposed in the literature.
引用
收藏
页码:470 / 484
页数:15
相关论文
共 50 条
  • [21] An Equidistant Segmentation-based Similarity Measure for Time Series
    Li, Xiaoru
    Kou, Xiangxia
    2020 13TH INTERNATIONAL CONGRESS ON IMAGE AND SIGNAL PROCESSING, BIOMEDICAL ENGINEERING AND INFORMATICS (CISP-BMEI 2020), 2020, : 429 - 434
  • [22] Time Series Similarity Measure Based on the Function of Degree of Disagreement
    Guo, Chonghui
    Zhang, Yanchang
    KNOWLEDGE SCIENCE, ENGINEERING AND MANAGEMENT, 2011, 7091 : 103 - 111
  • [23] DLCSS: A new similarity measure for time series data mining
    Soleimani, Gholamreza
    Abessi, Masoud
    ENGINEERING APPLICATIONS OF ARTIFICIAL INTELLIGENCE, 2020, 92
  • [24] Research on shape-based time series similarity measure
    Dong, Xiao-Li
    Gu, Cheng-Kui
    Wang, Zheng-Ou
    Dianzi Yu Xinxi Xuebao/Journal of Electronics and Information Technology, 2007, 29 (05): : 1228 - 1231
  • [25] Spin saturation artifact correction using slice-to-volume registration motion estimates for fMRI time series
    Bhagalia, Roshni
    Kim, Boklye
    MEDICAL PHYSICS, 2008, 35 (02) : 424 - 434
  • [26] Fast Constrained Dynamic Time Warping for Similarity Measure of Time Series Data
    Choi, Wonyoung
    Cho, Jaechan
    Lee, Seongjoo
    Jung, Yunho
    IEEE ACCESS, 2020, 8 : 222841 - 222858
  • [27] Multivariate Time Series Similarity Measure Based on Weighted Dynamic Time Warping
    Zhao, Jinhui
    Ju, Rusheng
    Xie, Xu
    Ye, Yanqing
    PROCEEDINGS OF 2020 2ND INTERNATIONAL CONFERENCE ON IMAGE PROCESSING AND MACHINE VISION AND INTERNATIONAL CONFERENCE ON PATTERN RECOGNITION AND MACHINE LEARNING, IPMV 2020, 2020, : 173 - 179
  • [28] Physiologic noise regression, motion regression, and TOAST dynamic field correction in complex-valued fMRI time series
    Hahn, Andrew D.
    Rowe, Daniel B.
    NEUROIMAGE, 2012, 59 (03) : 2231 - 2240
  • [29] Improved motion correction of submillimetre 7T fMRI time series with Boundary-Based Registration (BBR)
    Huang, Pei
    Carlin, Johan D.
    Henson, Richard N.
    Correia, Marta M.
    NEUROIMAGE, 2020, 210
  • [30] A dual echo approach to removing motion artefacts in fMRI time series
    Buur, Pieter F.
    Poser, Benedikt A.
    Norris, David G.
    NMR IN BIOMEDICINE, 2009, 22 (05) : 551 - 560