Physical Characterization and Clinical Experience for An Integrated 160-Leaf Multi-Leaf Collimator with a New Concept Design

被引:0
|
作者
Nakaguchi, Y. [1 ]
Araki, F. [1 ]
Ono, T. [1 ]
Inata, H. [1 ]
机构
[1] Kumamoto Univ, Kumamoto, Japan
关键词
D O I
10.1118/1.4814826
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
引用
收藏
页数:2
相关论文
共 38 条
  • [1] Physical Characterization of a New Concept Design of an Elekta Radiation Head with Integrated 160-leaf Multi-leaf Collimator
    Cosgrove, V. P.
    Thomas, M. D. R.
    Weston, S. J.
    Thompson, M. G.
    Reynaert, N.
    Evans, C. J.
    Brown, K. J.
    De Wagter, C.
    Thwaites, D. I.
    Warrington, A. P.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S722 - S723
  • [2] Characterization of an extendable multi-leaf collimator for clinical electron beams
    O'Shea, Tuathan P.
    Ge, Yuanyuan
    Foley, Mark J.
    Faddegon, Bruce A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (23): : 7621 - 7638
  • [3] Philips Pinnacle Photon Beam Modeling for Elekta Agility 160 Leaf Multi-Leaf Collimator
    Girard, F.
    Hinse, M.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [4] Clinical significance of multi-leaf collimator calibration errors
    Norvill, Craig
    Jenetsky, Guy
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2016, 39 (01) : 253 - 258
  • [5] Preliminary inter-leaf transmission characterization of a neutron multi-leaf collimator
    Farr, J
    Yudelev, M
    Maughan, R
    Forman, J
    Blosser, E
    Horste, T
    MEDICAL PHYSICS, 2002, 29 (06) : 1327 - 1327
  • [6] Clinical significance of multi-leaf collimator calibration errors
    Craig Norvill
    Guy Jenetsky
    Australasian Physical & Engineering Sciences in Medicine, 2016, 39 : 253 - 258
  • [7] An analytical approach for optimizing the leaf design of a multi-leaf collimator in a linear accelerator
    Topolnjak, R.
    van der Heide, U. A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (11): : 3007 - 3021
  • [8] Integration of the function generation synthesis into the design of a multi-leaf collimator
    Erkin Gezgin
    Mustafa Volkan Yazici
    Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2020, 42
  • [9] Small field dosimetric characterization of a new 160-leaf MLC
    Cranmer-Sargison, G.
    Liu, P. Z. Y.
    Weston, S.
    Suchowerska, N.
    Thwaites, D. I.
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (20): : 7343 - 7354
  • [10] Clinical Feasibility of Multi-Leaf Collimator Based Dynamic Wedge
    Jeong, C.
    Kwak, J.
    Alm, S.
    Kim, J.
    Park, J.
    Yoon, S.
    Cho, B.