Comparison of Fixation Stability of Resorbable Versus Titanium Plate and Screws in Mandibular Angle Fractures

被引:38
作者
Bayram, Burak
Araz, Kenan [1 ]
Uckan, Sina [1 ]
Balcik, Cenk [2 ]
机构
[1] Baskent Univ, Dept Oral & Maxillofacial Surg, Sch Dent, TR-06490 Ankara, Turkey
[2] Baskent Univ, Dept Mech Engn, TR-06490 Ankara, Turkey
关键词
SPLIT RAMUS OSTEOTOMY; BITE FORCES; SHEEP; SURGERY; POLYLACTIDE; MINIPLATE; MANDIBLES; MODEL;
D O I
10.1016/j.joms.2009.03.011
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of this study was to compare the fixation reliability and stability of titanium and resorbable plates and screws by simulating chewing forces. Materials and Methods: Mandibular angle fractures in 11 sheep hemimandibles were fixed with 4-hole straight titanium plates and 2.0 x 7-mm titanium screws; in addition, 11 hemimandibles were fixed with 4-hole straight resorbable plates and 2.5 x 6-mm resorbable screws according to the Champy technique. The hemimandibles were mounted with a fixation device in a servohydraulic testing unit for compressive testing. Displacement values under 20, 60, 100, 120, 150, and 200 N; maximum displacements; and maximum forces that the model could resist before breakage were recorded and compared. Results: Significant differences were found between resorbable and titanium plates and screws at all forces (20, 60, 100, 120, 150, and 200 N) (P < .05), We found no statistically significant differences in the breaking force and maximum displacement values (displacement values at the breaking forces) between the groups. Conclusions: The stability of mandibular angle fractures with titanium miniplates under simulated chewing forces was significantly higher than with the resorbable system. Metallic and resorbable fixation systems cannot be used interchangeably to treat mandibular angle fractures under similar loading conditions. (C) 2009 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Surg 67:1644-1648, 2009
引用
收藏
页码:1644 / 1648
页数:5
相关论文
共 16 条
[1]   THE SHEEP AS A MODEL FOR TEMPOROMANDIBULAR-JOINT SURGERY [J].
BOSANQUET, AG ;
GOSS, AN .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1987, 16 (05) :600-603
[2]   Comparison of strains produced by titanium and poly D,L-lactide acid plating systems to in vitro forces [J].
Chacon, GE ;
Rashid, R .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2005, 63 (07) :968-972
[3]   Immediate mechanical stability of sagittal split ramus osteotomy fixed with resorbable compared with titanium bicortical screws in mandibles of sheep [J].
Cilasun, Ulkem ;
Uckan, Sina ;
Dolanmaz, Dogan ;
Saglam, Haci .
BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2006, 44 (06) :534-537
[4]   Comparison of stability of absorbable and titanium plate and screw fixation for sagittal split ramus osteotomy [J].
Dolanmaz, D ;
Uckan, S ;
Isik, K ;
Saglam, H .
BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2004, 42 (02) :127-132
[5]   Treatment of mandibular angle fractures using one noncompression miniplate [J].
Ellis, E ;
Walker, LR .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1996, 54 (07) :864-871
[6]   Maxillofacial Fractures.: Analysis of demographic distribution and treatment in 2901 patients (25-year experience) [J].
Erol, BE ;
Tanrikulu, R ;
Görgün, B .
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2004, 32 (05) :308-313
[7]  
GERLACH KL, 1993, CLIN MATER, V13, P21, DOI 10.1016/0267-6605(93)90085-L
[8]   Bite forces in patients after treatment of mandibular angle fractures with miniplate osteosynthesis according to Champy [J].
Gerlach, KL ;
Schwarz, A .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2002, 31 (04) :345-348
[9]   Biodegradable polylactide plates and screws in orthognathic surgery: technical note [J].
Haers, PE ;
Suuronen, R ;
Lindqvist, C ;
Sailer, H .
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 1998, 26 (02) :87-91
[10]   Detection of titanium in human tissues after craniofacial surgery [J].
Jorgenson, DS ;
Mayer, MH ;
Ellenbogen, RG ;
Centeno, JA ;
Johnson, FB ;
Mullick, FG ;
Manson, PN .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1997, 99 (04) :976-979