Intraoperative cortical surface characterization using laser range scanning: Preliminary results

被引:18
作者
Sinha, Tuhin K.
Miga, Michael I.
Cash, David M.
Weil, Robert J.
机构
[1] Vanderbilt Univ, Dept Biomed Engn, Nashville, TN 37235 USA
[2] Cleveland Clin Fdn, Dept Pituitary & Endocrine Surg, Brain Tumor Inst, Cleveland, OH 44195 USA
关键词
brain shift; cortical surface; image-guided surgery; registration; visualization;
D O I
10.1227/01.NEU.0000222665.40301.D2
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: To present a,,novel methodology that uses a laser range scanner (LRS) capable of generating textured (intensity-encoded) surface descriptions of the brain surface for use with image-to-patient registration and improved cortical feature recognition during intraoperative neurosurgical navigation. METHODS: An LRS device was used to acquire cortical surface descriptions of eight patients undergoing neurosurgery for a variety of clinical presentations. Textured surface descriptions were generated from these intraoperative acquisitions for each patient. Corresponding textured surfaces were also generated from each patient's preoperative magnetic resonance tomograms. Each textured surface pair (LRS and magnetic resonance tomogram) was registered using only cortical surface information. Novel visualization of the combined surfaces allowed for registration assessment based on quantitative cortical feature alignment. RESULTS: Successful textured LRS surface acquisition and generation was performed on all eight patients. The data acquired by the LRS accurately presented the intraoperative surface of the cortex and the associated features within the surgical field-of-view. Registration results are presented as overlays of the intraoperative data with respect to the preoperative data and quantified by comparing mean distances between cortical features on the magnetic resonance tomogram and LRS surfaces after registration. The overlays demonstrated that accurate registration can be provided between the preoperative and intraoperative data and emphasized a potential enhancement to cortical feature recognition within the operating room environment. Using the best registration result from each clinical case, the mean feature alignment error is 1.7 +/- 0.8 mm over all cases. CONCLUSION: This study demonstrates clinical deployment of an LRS capable of generating textured surfaces of the surgical field of view. Data from the LRS was registered accurately to the corresponding preoperative data. Visual inspection of the registration results was provided by overlays that put the intraoperative data within the perspective of the whole brain's surface. These visuals can be used to more readily assess the fidelity of image-to-patient registration, as well as to enhance recognition of cortical features for assistance in comparing the neurotopography between magnetic resonance image volume and physical patient. in addition, the feature-rich data presented here provides considerable motivation for using LRS scanning to measure deformation during surgery.
引用
收藏
页码:368 / 376
页数:9
相关论文
共 27 条
  • [21] Inside Late Bronze Age Settlements in NE Romania: GIS-Based Surface Characterization of Ashmound Structures Using Airborne Laser Scanning and Aerial Photography Techniques
    Brasoveanu, Casandra
    Mihu-Pintilie, Alin
    Brunchi, Radu-Alexandru
    REMOTE SENSING, 2023, 15 (17)
  • [22] Retinal Hemorheologic Characterization of Early-Stage Diabetic Retinopathy Using Adaptive Optics Scanning Laser Ophthalmoscopy
    Arichika, Shigeta
    Uji, Akihito
    Murakami, Tomoaki
    Unoki, Noriyuki
    Yoshitake, Shin
    Dodo, Yoko
    Ooto, Sotaro
    Miyamoto, Kazuaki
    Yoshimura, Nagahisa
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (12) : 8513 - 8522
  • [23] Detection of surface change in complex topography using terrestrial laser scanning: application to the Illgraben debris-flow channel
    Schuerch, Peter
    Densmore, Alexander L.
    Rosser, Nicholas J.
    Lim, Michael
    McArdell, Brian W.
    EARTH SURFACE PROCESSES AND LANDFORMS, 2011, 36 (14) : 1847 - 1859
  • [24] In situ 3D characterization of monodispersed spherical particle deposition on microsieve using confocal laser scanning microscopy
    Ben Hassan, Ines
    Lafforgue, Christine
    Ayadi, Abdelmoneim
    Schmitz, Philippe
    JOURNAL OF MEMBRANE SCIENCE, 2014, 454 : 283 - 297
  • [25] Characterization of single-file flow through human retinal parafoveal capillaries using an adaptive optics scanning laser ophthalmoscope
    Tam, Johnny
    Tiruveedhula, Pavan
    Roorda, Austin
    BIOMEDICAL OPTICS EXPRESS, 2011, 2 (04): : 781 - 793
  • [26] Surface-based image-to-patient registration using a hand-guided laser-range scanner system
    Korb, W
    Bodenmüller, T
    Eggers, G
    Ortmaier, T
    Schneberger, M
    Suppa, M
    Wiechnik, J
    Marmulla, R
    Hassfeld, S
    CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2004, 1268 : 1328 - 1328
  • [27] Characterization of membrane biofouling at different operating conditions (flux) in drinking water treatment using confocal laser scanning microscopy (CLSM) and image analysis
    Sun, Cheng
    Fiksdal, Liv
    Hanssen-Bauer, Audun
    Rye, Morten B.
    Leiknes, TorOve
    JOURNAL OF MEMBRANE SCIENCE, 2011, 382 (1-2) : 194 - 201