Enhancement of sensitivity and specificity by surface modification of carbon nanotubes in diagnosis of prostate cancer based on carbon nanotube field effect transistors
被引:118
作者:
Kim, Jun Pyo
论文数: 0引用数: 0
h-index: 0
机构:
Sungkyunkwan Univ, Dept Chem Engn, Nanoopt & Biomol Engn Natl Lab, Suwon 440746, South KoreaSungkyunkwan Univ, Dept Chem Engn, Nanoopt & Biomol Engn Natl Lab, Suwon 440746, South Korea
Kim, Jun Pyo
[1
]
Lee, Byung Yang
论文数: 0引用数: 0
h-index: 0
机构:
Seoul Natl Univ, Dept Phys & Astron, Seoul 151742, South KoreaSungkyunkwan Univ, Dept Chem Engn, Nanoopt & Biomol Engn Natl Lab, Suwon 440746, South Korea
Lee, Byung Yang
[2
]
Lee, Joohyung
论文数: 0引用数: 0
h-index: 0
机构:
Seoul Natl Univ, Dept Phys & Astron, Seoul 151742, South KoreaSungkyunkwan Univ, Dept Chem Engn, Nanoopt & Biomol Engn Natl Lab, Suwon 440746, South Korea
Lee, Joohyung
[2
]
Hong, Seunghun
论文数: 0引用数: 0
h-index: 0
机构:
Seoul Natl Univ, Dept Phys & Astron, Seoul 151742, South KoreaSungkyunkwan Univ, Dept Chem Engn, Nanoopt & Biomol Engn Natl Lab, Suwon 440746, South Korea
Hong, Seunghun
[2
]
Sim, Sang Jun
论文数: 0引用数: 0
h-index: 0
机构:
Sungkyunkwan Univ, Dept Chem Engn, Nanoopt & Biomol Engn Natl Lab, Suwon 440746, South KoreaSungkyunkwan Univ, Dept Chem Engn, Nanoopt & Biomol Engn Natl Lab, Suwon 440746, South Korea
Sim, Sang Jun
[1
]
机构:
[1] Sungkyunkwan Univ, Dept Chem Engn, Nanoopt & Biomol Engn Natl Lab, Suwon 440746, South Korea
[2] Seoul Natl Univ, Dept Phys & Astron, Seoul 151742, South Korea
This paper presents a simple and sensitive method for the real-time detection of a prostate cancer marker (PSA-ACT complex) through label-free protein biosensors based on a carbon nanotube field effect transistor (CNT-FET). Herein, the CNT-FET was functionalized with a solution containing various linker-to-spacer ratios, the binding event of the target PSA-ACT complex onto the receptor detected by monitoring the gating effect caused by charges in the target PSA-ACT complex. Since the biosensors were used in a buffer solution, it was crucial to control the distance between the receptors through introduction of linkers and spacers so that the charged target PSA-ACT complex could easily approach the CNT surface within the Debye length to give a large gating effect. The results show that CNT-FET biosensors modified with only linkers could not detect target proteins unless a very high concentration of the PSA-ACT complex solution (similar to 500 ng/ml) was injected, while those modified with a 1:3 ratio of linker-to-spacer could detect 1.0 ng/ml without any pretreatment. Moreover, our linker and spacer-modified CNT-FET could successfully block non-target proteins and selectively detect the target protein in human serum. Significantly, this strategy can be applied to general antibody-based detection schemes and enables production of very simple and sensitive electronic biosensors to detect clinically important biomarkers for disease diagnosis. (C) 2009 Elsevier B.V. All rights reserved.
机构:
Hauptman Woodward Med Res Inst, Endocrine Biochem Dept, Buffalo, NY 14203 USAHauptman Woodward Med Res Inst, Endocrine Biochem Dept, Buffalo, NY 14203 USA
Ng, PC
;
Osawa, Y
论文数: 0引用数: 0
h-index: 0
机构:
Hauptman Woodward Med Res Inst, Endocrine Biochem Dept, Buffalo, NY 14203 USAHauptman Woodward Med Res Inst, Endocrine Biochem Dept, Buffalo, NY 14203 USA
机构:
Hauptman Woodward Med Res Inst, Endocrine Biochem Dept, Buffalo, NY 14203 USAHauptman Woodward Med Res Inst, Endocrine Biochem Dept, Buffalo, NY 14203 USA
Ng, PC
;
Osawa, Y
论文数: 0引用数: 0
h-index: 0
机构:
Hauptman Woodward Med Res Inst, Endocrine Biochem Dept, Buffalo, NY 14203 USAHauptman Woodward Med Res Inst, Endocrine Biochem Dept, Buffalo, NY 14203 USA