Tissue Characterization of In-Stent Neointima Using Optical Coherence Tomography in the Late Phase After Bare-Metal Stent Implantation - An Ex Vivo Validation Study
被引:17
作者:
Shibuya, Masahiko
论文数: 0引用数: 0
h-index: 0
机构:
Hyogo Coll Med, Div Cardiovasc, Nishinomiya, Hyogo 6638501, JapanHyogo Coll Med, Div Cardiovasc, Nishinomiya, Hyogo 6638501, Japan
Shibuya, Masahiko
[1
]
Fujii, Kenichi
论文数: 0引用数: 0
h-index: 0
机构:
Hyogo Coll Med, Div Cardiovasc, Nishinomiya, Hyogo 6638501, JapanHyogo Coll Med, Div Cardiovasc, Nishinomiya, Hyogo 6638501, Japan
Fujii, Kenichi
[1
]
Hao, Hiroyuki
论文数: 0引用数: 0
h-index: 0
机构:
Hyogo Coll Med, Dept Surg Pathol, Nishinomiya, Hyogo 6638501, JapanHyogo Coll Med, Div Cardiovasc, Nishinomiya, Hyogo 6638501, Japan
Hao, Hiroyuki
[2
]
Imanaka, Takahiro
论文数: 0引用数: 0
h-index: 0
机构:
Hyogo Coll Med, Div Cardiovasc, Nishinomiya, Hyogo 6638501, JapanHyogo Coll Med, Div Cardiovasc, Nishinomiya, Hyogo 6638501, Japan
Imanaka, Takahiro
[1
]
Saita, Ten
论文数: 0引用数: 0
h-index: 0
机构:
Hyogo Coll Med, Div Cardiovasc, Nishinomiya, Hyogo 6638501, JapanHyogo Coll Med, Div Cardiovasc, Nishinomiya, Hyogo 6638501, Japan
Saita, Ten
[1
]
Fukunaga, Masashi
论文数: 0引用数: 0
h-index: 0
机构:
Hyogo Coll Med, Div Cardiovasc, Nishinomiya, Hyogo 6638501, JapanHyogo Coll Med, Div Cardiovasc, Nishinomiya, Hyogo 6638501, Japan
Fukunaga, Masashi
[1
]
Miki, Kojiro
论文数: 0引用数: 0
h-index: 0
机构:
Hyogo Coll Med, Div Cardiovasc, Nishinomiya, Hyogo 6638501, JapanHyogo Coll Med, Div Cardiovasc, Nishinomiya, Hyogo 6638501, Japan
Miki, Kojiro
[1
]
Tamaru, Hiroto
论文数: 0引用数: 0
h-index: 0
机构:
Hyogo Coll Med, Div Cardiovasc, Nishinomiya, Hyogo 6638501, JapanHyogo Coll Med, Div Cardiovasc, Nishinomiya, Hyogo 6638501, Japan
Tamaru, Hiroto
[1
]
Nishimura, Machiko
论文数: 0引用数: 0
h-index: 0
机构:
Hyogo Coll Med, Div Cardiovasc, Nishinomiya, Hyogo 6638501, JapanHyogo Coll Med, Div Cardiovasc, Nishinomiya, Hyogo 6638501, Japan
Nishimura, Machiko
[1
]
Horimatsu, Tetsuo
论文数: 0引用数: 0
h-index: 0
机构:
Hyogo Coll Med, Div Cardiovasc, Nishinomiya, Hyogo 6638501, JapanHyogo Coll Med, Div Cardiovasc, Nishinomiya, Hyogo 6638501, Japan
Horimatsu, Tetsuo
[1
]
Naito, Yoshiro
论文数: 0引用数: 0
h-index: 0
机构:
Hyogo Coll Med, Div Cardiovasc, Nishinomiya, Hyogo 6638501, JapanHyogo Coll Med, Div Cardiovasc, Nishinomiya, Hyogo 6638501, Japan
Naito, Yoshiro
[1
]
Ishibashi-Ueda, Hatsue
论文数: 0引用数: 0
h-index: 0
机构:
Natl Cerebral & Cardiovasc Ctr, Dept Pathol, Suita, Osaka, JapanHyogo Coll Med, Div Cardiovasc, Nishinomiya, Hyogo 6638501, Japan
Ishibashi-Ueda, Hatsue
[3
]
Hirota, Seiichi
论文数: 0引用数: 0
h-index: 0
机构:
Hyogo Coll Med, Dept Surg Pathol, Nishinomiya, Hyogo 6638501, JapanHyogo Coll Med, Div Cardiovasc, Nishinomiya, Hyogo 6638501, Japan
Hirota, Seiichi
[2
]
Masuyama, Tohru
论文数: 0引用数: 0
h-index: 0
机构:
Hyogo Coll Med, Div Cardiovasc, Nishinomiya, Hyogo 6638501, JapanHyogo Coll Med, Div Cardiovasc, Nishinomiya, Hyogo 6638501, Japan
Masuyama, Tohru
[1
]
机构:
[1] Hyogo Coll Med, Div Cardiovasc, Nishinomiya, Hyogo 6638501, Japan
Background: We performed an ex vivo study to investigate optical coherence tomography (OCT) imaging for differentiating several types of neointimal tissue during the later phases after bare-metal stent (BMS) implantation as compared with histologic results. Methods and Results: OCT imaging was performed in 6 autopsy hearts for 10 BMS with implant duration >4 years. OCT qualitative neointimal tissue characterization was based on tissue structure and classified as homogeneous pattern, heterogeneous pattern with visible struts, or heterogeneous pattern with invisible struts. Corresponding histological analyses of each 2-mm cross-section of the entire BMS were performed. Of 81 cross-sections, histological analysis revealed that the homogeneous pattern of neointima on OCT (n=39) contained smooth muscle cells with collagen, indicating high neointimal maturity. The heterogeneous patterns with visible struts (n=35) contained different tissues, including a proteoglycan-rich myxomatous matrix or dense calcified plate deposition. The heterogeneous patterns with invisible struts (n=7) included neointimal lipid/necrotic core formation, accumulation of foam cells, or microcalcification scattering. Of the 66 cross-sections containing large microvessels within the neointima on histology, only 6 (9%) were visualized by OCT. Conclusions: The present study confirmed the potential use of OCT in differentiating several types of neointima after BMS implantation. The image interpretation of OCT, based on visualization of stent struts, enables identification of several types of neointimal tissues, including in-stent fibroatheroma formation, more accurately.
机构:
Department of Pathology, Case Western Reserve University, Cleveland, OH 44106, United StatesDepartment of Pathology, Case Western Reserve University, Cleveland, OH 44106, United States
机构:
Department of Pathology, Case Western Reserve University, Cleveland, OH 44106, United StatesDepartment of Pathology, Case Western Reserve University, Cleveland, OH 44106, United States